This research is about the inspection system which is for maintenance of laterals of local RBF(River bed Filtration). Inspection system is designed for local use in order to endure water resistance up to 50m and it also can examine the internal condit...
This research is about the inspection system which is for maintenance of laterals of local RBF(River bed Filtration). Inspection system is designed for local use in order to endure water resistance up to 50m and it also can examine the internal condition and colgging of laterals by moving inside of the laterals about 100m back and forward. We will conduct performance test of inspection system at the lacal RBF site and present its result.