RISS 학술연구정보서비스

검색

인기 검색어

    다국어 입력

    http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

    변환된 중국어를 복사하여 사용하시면 됩니다.

    예시)
    • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
    • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
    닫기

    무궁화 열차 내 화장실 악취농도에 관한 연구 = A study on odor concentrations in toilets in mugunghwa trains

    한글로보기

    https://www.riss.kr/link?id=A100386272

    • 0

      상세조회
    • 0

      다운로드
    서지정보 열기
    • 내보내기
    • 내책장담기
    • 공유하기
      • URL 복사
    • 오류접수
    인용문이 복사되었습니다.

    부가정보

    다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

    This study was carried out to estimate odors emitted from toilets in Mugunghwa trains. Two parameters, odor intensity and odor concentration, were used for odor estimation. A direct olfactory method to observe odor intensity for 67 toilets and an air dilution olfactory method to estimate odor concentration for 6 samples were performed. Results showed that odor concentrations in toilets in trains ranged from 6 OU/m3 to 30 OU/m3, and odor intensity in 67 toilets varied from 0 degree to 3.3 degree. The results suggest that odors emitted from existing toilets should be controlled because the odor intensity in 16 toilets reached a level that resulted in complaints about the odor.
    번역하기

    This study was carried out to estimate odors emitted from toilets in Mugunghwa trains. Two parameters, odor intensity and odor concentration, were used for odor estimation. A direct olfactory method to observe odor intensity for 67 toilets and an air ...

    This study was carried out to estimate odors emitted from toilets in Mugunghwa trains. Two parameters, odor intensity and odor concentration, were used for odor estimation. A direct olfactory method to observe odor intensity for 67 toilets and an air dilution olfactory method to estimate odor concentration for 6 samples were performed. Results showed that odor concentrations in toilets in trains ranged from 6 OU/m3 to 30 OU/m3, and odor intensity in 67 toilets varied from 0 degree to 3.3 degree. The results suggest that odors emitted from existing toilets should be controlled because the odor intensity in 16 toilets reached a level that resulted in complaints about the odor.

    더보기

    목차 (Table of Contents)

    • 1. 서 론
    • 2. 실험 방법
    • 3. 결과 및 고찰
    • 4. 결 론
    • 1. 서 론
    • 2. 실험 방법
    • 3. 결과 및 고찰
    • 4. 결 론
    더보기

    분석정보

    View

    상세정보조회

    0

    Usage

    원문다운로드

    0

    대출신청

    0

    복사신청

    0

    EDDS신청

    0

    동일 주제 내 활용도 TOP

    더보기

    주제

    연도별 연구동향

    연도별 활용동향

    연관논문

    연구자 네트워크맵

    공동연구자 (7)

    유사연구자 (20) 활용도상위20명

    해외이동버튼