      Laser Doppler Flowmeter를 이용한 국소 부신 피질 홀몬제의 혈관 수축도의 측정 = Measurement of Vascular Corticosteroid Effect in Human using Laser Doppler FlowmeterLaser Doppler Flowmeter를 이용한 국소 부신 피질 홀몬제의 혈관 수축도의 측정

      한글로보기

      https://www.riss.kr/link?id=A3286705

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Vasoconstrictive effect of several topicsl corticosteroids was measured using laser Doppler flowmeter. Hydrophilic ointment base, 1% hydrocortisone cream, 0.1% clocortolone pivalate cream, and 0.25% desoxymethasone cream were applied on both forearms of 20 volunteers. To augment the vasoconstrictive effect of the corticosteroids, We had cut off the blood flow to forearms for 4 minutes by tourniquet. The reactive
      hyperemia was measured by laser Doppler flowmeter and the ares under the curve were calculated by digitizer aided by a computer. The mean areas of esch drugs were in the following order : hydrophilic ointment base, 0.1% clocortolone pivalate cream, 1% hydrocortisone crearn and 0.25% desoxymethasone cream. However, the standard
      deviations were too large for the difference to be statistically significant. We concluded that laser Doppler flowmeter is not suitable for the measurement of vasoconstrictive effect of corticosteroid.
      번역하기

      Vasoconstrictive effect of several topicsl corticosteroids was measured using laser Doppler flowmeter. Hydrophilic ointment base, 1% hydrocortisone cream, 0.1% clocortolone pivalate cream, and 0.25% desoxymethasone cream were applied...

      Vasoconstrictive effect of several topicsl corticosteroids was measured using laser Doppler flowmeter. Hydrophilic ointment base, 1% hydrocortisone cream, 0.1% clocortolone pivalate cream, and 0.25% desoxymethasone cream were applied on both forearms of 20 volunteers. To augment the vasoconstrictive effect of the corticosteroids, We had cut off the blood flow to forearms for 4 minutes by tourniquet. The reactive
      hyperemia was measured by laser Doppler flowmeter and the ares under the curve were calculated by digitizer aided by a computer. The mean areas of esch drugs were in the following order : hydrophilic ointment base, 0.1% clocortolone pivalate cream, 1% hydrocortisone crearn and 0.25% desoxymethasone cream. However, the standard
      deviations were too large for the difference to be statistically significant. We concluded that laser Doppler flowmeter is not suitable for the measurement of vasoconstrictive effect of corticosteroid.