RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCOPUS

      인공 치아우식 발생 모델에서 디지털 방사선 공제술을 이용한 인접면 치아우식증의 진단 = Proximal caries detection using digital subtraction radiography in the artificial caries activity model

      한글로보기

      https://www.riss.kr/link?id=A82406242

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Purpose : The purpose of the experiment was to evaluating the diagnostic ability of dental caries detection using digital subtraction in the artificial caries activity model.
      Materials and Methods : Digital radiographies of five teeth with 8 proximal surfaces were obtained by CCD sensor (Kodak RVG 6100 using a size #2). The digital radiographic images and subtraction images from artificial proximal caries were examined and interpreted. In this study, we proposed novel caries detection method which could diagnose the dental proximal caries from single digital radiographic image.
      Results : In artificial caries activity model, the range of lesional depth was 572-1,374 μm and the range of lesional area was 36.95-138.52mm². The lesional depth and the area were significantly increased with demineralization time (p<0.001). Furthermore, the proximal caries detection using digital subtraction radiography showed high detection rate compared to the proximal caries examination using simple digital radiograph.
      Conclusion : The results demonstrated that the digital subtraction radiography from single radiographic image of artificial caries was highly efficient in the detection of dental caries compared to the data from simple digital radiograph.
      번역하기

      Purpose : The purpose of the experiment was to evaluating the diagnostic ability of dental caries detection using digital subtraction in the artificial caries activity model. Materials and Methods : Digital radiographies of five teeth with 8 proximal...

      Purpose : The purpose of the experiment was to evaluating the diagnostic ability of dental caries detection using digital subtraction in the artificial caries activity model.
      Materials and Methods : Digital radiographies of five teeth with 8 proximal surfaces were obtained by CCD sensor (Kodak RVG 6100 using a size #2). The digital radiographic images and subtraction images from artificial proximal caries were examined and interpreted. In this study, we proposed novel caries detection method which could diagnose the dental proximal caries from single digital radiographic image.
      Results : In artificial caries activity model, the range of lesional depth was 572-1,374 μm and the range of lesional area was 36.95-138.52mm². The lesional depth and the area were significantly increased with demineralization time (p<0.001). Furthermore, the proximal caries detection using digital subtraction radiography showed high detection rate compared to the proximal caries examination using simple digital radiograph.
      Conclusion : The results demonstrated that the digital subtraction radiography from single radiographic image of artificial caries was highly efficient in the detection of dental caries compared to the data from simple digital radiograph.

      더보기

      참고문헌 (Reference)

      1 Abreu Junior M, "Two and three-dimensional imaging modalities for the detection of caries. A comparison between film, digital radiography and tuned aperture computed tomography (TACT)" 28 : 152-157, 1999

      2 Wenzel A, "Reproducibility in the assessment of caries lesion behaviour: a comparison between conventional film and subtraction radiography" 34 : 214-218, 2000

      3 Levine RS, "Remineralization of natural caries lesion on enamel" 137 : 132-141, 1974

      4 Dagenais ME, "Receiver operating characteristics of Radio-VisioGraphy" 79 : 238-245, 1995

      5 Abreu M Jr, "Performance of RVGui sensor and Kodak Ektaspeed Plus film for proximal caries detection" 91 : 381-385, 2001

      6 White SC, "Oral Radiology: principles and interpretation. 4th ed" Mosby 277-279, 2000

      7 Nummikoski NB, "Digital subtraction radiography in artificial recurrent caries detection" 21 : 59-64, 1992

      8 Eberhard J, "Digital subtraction radiography for monitoring dental demineralization" 34 : 219-224, 2000

      9 Nair MK, "Diagnostic accuracy of intraoral film and direct digital images for detection of simulated recurrent decay" 26 : 223-230, 2001

      10 Halse A, "Detection of mineral loss in approximal enamel by subtraction radiography" 77 : 177-182, 1994

      1 Abreu Junior M, "Two and three-dimensional imaging modalities for the detection of caries. A comparison between film, digital radiography and tuned aperture computed tomography (TACT)" 28 : 152-157, 1999

      2 Wenzel A, "Reproducibility in the assessment of caries lesion behaviour: a comparison between conventional film and subtraction radiography" 34 : 214-218, 2000

      3 Levine RS, "Remineralization of natural caries lesion on enamel" 137 : 132-141, 1974

      4 Dagenais ME, "Receiver operating characteristics of Radio-VisioGraphy" 79 : 238-245, 1995

      5 Abreu M Jr, "Performance of RVGui sensor and Kodak Ektaspeed Plus film for proximal caries detection" 91 : 381-385, 2001

      6 White SC, "Oral Radiology: principles and interpretation. 4th ed" Mosby 277-279, 2000

      7 Nummikoski NB, "Digital subtraction radiography in artificial recurrent caries detection" 21 : 59-64, 1992

      8 Eberhard J, "Digital subtraction radiography for monitoring dental demineralization" 34 : 219-224, 2000

      9 Nair MK, "Diagnostic accuracy of intraoral film and direct digital images for detection of simulated recurrent decay" 26 : 223-230, 2001

      10 Halse A, "Detection of mineral loss in approximal enamel by subtraction radiography" 77 : 177-182, 1994

      11 Pitts NB, "Detection and measurement of approximal radiolucencies by computer-aided image analysis of bitewing radiographs" 58 : 358-366, 1984

      12 Uprichard KK, "Comparison of direct digital and conventional radiography for the detection of proximal surface caries in the mixed dentition" 22 : 9-15, 2000

      13 Douglass CW, "Clinical efficacy of dental radiography in the detection of dental caries and periodontal disease" 62 : 330-339, 1986

      14 Besic FC, "Caries like enamel changes by chemical means" 32 : 830-841, 1953

      15 Svanaes DB, "Approximal caries depth assessment with storage phosphor versus film radiography. Evaluation of the caries-specific Oslo enhancement procedure" 34 : 448-453, 2000

      16 Dove SB, "Analysis of sensitivity and specificity of a new digital subtraction system" 89 : 771-776, 2000

      17 Nair MK, "An in-vitro evaluation of Kodak Insight and Ektaspeed Plus film with a CMOS detector for natural proximal caries: ROC analysis" 35 : 354-359, 2001

      18 Maggio JJ, "A model for dentinal caries progression by digital subtraction radiography" 64 : 727-732, 1990

      19 Price C, "A comparison of a film-based and a direct digital dental radiographic system using a proximal caries model" 26 : 45-52, 1997

      20 Gratt BM, "A clinical comparison between xeroradiography and film radiography for the detection of recurrent caries" 65 : 483-489, 1988

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2019-03-27 학회명변경 한글명 : 대한구강악안면방사선학회 -> 대한영상치의학회 KCI등재
      2012-04-16 학술지명변경 한글명 : 대한구강악안면방사선학회지 -> Imaging Science in Dentistry KCI등재
      2011-03-29 학술지명변경 외국어명 : Korean Journal of Oral and Maxillofacial Radiology -> Imaging Science in Dentistry KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2008-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2006-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2003-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2002-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2000-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.12 0.12 0.11
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.11 0.12 0.217 0.02
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼