RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재

      Intraoperative periprosthetic humeral fracture during reverse shoulder arthroplasty: a sequelae of prior biceps tenodesis

      한글로보기

      https://www.riss.kr/link?id=A108488561

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Intraoperative periprosthetic humeral fractures are a rare but debilitating complication of reverse shoulder arthroplasty and can occur during multiple stages of the procedure. Prior biceps tenodesis has been found to reduce cortical humeral strength and predispose the patient to humeral fracture. We present a case of a 68-year-old female with a previous history of biceps tenodesis due to an irreparable rotator cuff tear. Months later, and after symptoms persisted, a reverse shoulder arthroplasty was performed. During the surgery and while performing final reduction, a fracture line was observed involving the hole used for the previous tenodesis procedure. The fracture was repaired, and the patient reported favorable outcomes. We report several factors that might have contributed to sustenance of this intraoperative fracture including prior biceps tenodesis, use of a press fit humeral stem, and the sex of the patient.
      번역하기

      Intraoperative periprosthetic humeral fractures are a rare but debilitating complication of reverse shoulder arthroplasty and can occur during multiple stages of the procedure. Prior biceps tenodesis has been found to reduce cortical humeral strength ...

      Intraoperative periprosthetic humeral fractures are a rare but debilitating complication of reverse shoulder arthroplasty and can occur during multiple stages of the procedure. Prior biceps tenodesis has been found to reduce cortical humeral strength and predispose the patient to humeral fracture. We present a case of a 68-year-old female with a previous history of biceps tenodesis due to an irreparable rotator cuff tear. Months later, and after symptoms persisted, a reverse shoulder arthroplasty was performed. During the surgery and while performing final reduction, a fracture line was observed involving the hole used for the previous tenodesis procedure. The fracture was repaired, and the patient reported favorable outcomes. We report several factors that might have contributed to sustenance of this intraoperative fracture including prior biceps tenodesis, use of a press fit humeral stem, and the sex of the patient.

      더보기

      참고문헌 (Reference)

      1 Wagner ER, "What are risk factors for intraoperative humerus fractures during revision reverse shoulder arthroplasty and do they influence outcomes" 473 : 3228-3234, 2015

      2 King JJ, "Uncemented versus cemented humeral stem fixation in reverse shoulder arthroplasty" 39 : 291-298, 2015

      3 Beason DP, "Torsional fracture of the humerus after subpectoral biceps tenodesis with an interference screw : a biomechanical cadaveric study" 30 : 915-920, 2015

      4 Dillon MT, "The increasing role of reverse total shoulder arthroplasty in the treatment of proximal humerus fractures" 50 : 676-680, 2019

      5 Eyberg BA, "Suture cerclage for stabilizing the humeral shaft during shoulder arthroplasty" 4 : 688-693, 2020

      6 Creech MJ, "Surgical indications for long head biceps tenodesis : a systematic review" 24 : 2156-2166, 2016

      7 Baleani M, "Suprapectoral biceps tenodesis : a biomechanical comparison of a new"soft anchor"tenodesis technique versus interference screw biceps tendon fixation" 30 : 188-194, 2015

      8 Hipp JA, "Structural consequences of transcortical holes in long bones loaded in torsion" 23 : 1261-1268, 1990

      9 Renner N, "Stainless steel wire versus FiberWire suture cerclage fixation to stabilize the humerus in total shoulder arthroplasty" 23 : 1568-1574, 2014

      10 Friedel R, "Proximal humerus shaft fracture as a complication after keyhole-plasty : a case report" 21 : 198-201, 1995

      1 Wagner ER, "What are risk factors for intraoperative humerus fractures during revision reverse shoulder arthroplasty and do they influence outcomes" 473 : 3228-3234, 2015

      2 King JJ, "Uncemented versus cemented humeral stem fixation in reverse shoulder arthroplasty" 39 : 291-298, 2015

      3 Beason DP, "Torsional fracture of the humerus after subpectoral biceps tenodesis with an interference screw : a biomechanical cadaveric study" 30 : 915-920, 2015

      4 Dillon MT, "The increasing role of reverse total shoulder arthroplasty in the treatment of proximal humerus fractures" 50 : 676-680, 2019

      5 Eyberg BA, "Suture cerclage for stabilizing the humeral shaft during shoulder arthroplasty" 4 : 688-693, 2020

      6 Creech MJ, "Surgical indications for long head biceps tenodesis : a systematic review" 24 : 2156-2166, 2016

      7 Baleani M, "Suprapectoral biceps tenodesis : a biomechanical comparison of a new"soft anchor"tenodesis technique versus interference screw biceps tendon fixation" 30 : 188-194, 2015

      8 Hipp JA, "Structural consequences of transcortical holes in long bones loaded in torsion" 23 : 1261-1268, 1990

      9 Renner N, "Stainless steel wire versus FiberWire suture cerclage fixation to stabilize the humerus in total shoulder arthroplasty" 23 : 1568-1574, 2014

      10 Friedel R, "Proximal humerus shaft fracture as a complication after keyhole-plasty : a case report" 21 : 198-201, 1995

      11 Jacobs AN, "Proximal humerus fracture following arthroscopic biceps tenodesis" 50 : 649-, 2020

      12 Reiff SN, "Proximal humerus fracture after keyhole biceps tenodesis" 39 : E61-3, 2010

      13 Athwal GS, "Periprosthetic humeral fractures during shoulder arthroplasty" 91 : 594-603, 2009

      14 Lee M, "Intramedullary reaming for press-fit fixation of a humeral component removes cortical bone asymmetrically" 17 : 150-155, 2008

      15 Chen CH, "Incidence and severity of biceps long head tendon lesion in patients with complete rotator cuff tears" 58 : 1189-1193, 2005

      16 Erdle NJ, "Humerus fractures after open subpectoral biceps tenodesis : three cases with 2-year functional outcome data and review of the literature" 10 : e0033-, 2020

      17 Ashmyan RI, "Humeral shaft fracture after open biceps tenodesis following use of continuous passive motion machine : a case report" 5 : 546-548, 2021

      18 Sears BW, "Humeral fracture following subpectoral biceps tenodesis in 2 active, healthy patients" 20 : e7-11, 2011

      19 Alswat KA, "Gender disparities in osteoporosis" 9 : 382-387, 2017

      20 American Academy of Orthopaedic Surgeons, "Clinical practice guideline on the management of rotator cuff injuries"

      21 Chiang FL, "Biomechanical comparison of all-suture anchor fixation and interference screw technique for subpectoral biceps tenodesis" 32 : 1247-1252, 2016

      22 Walch G, "Arthroscopic tenotomy of the long head of the biceps in the treatment of rotator cuff tears : clinical and radiographic results of 307 cases" 14 : 238-246, 2005

      23 Denard PJ, "A tensionable suture-based cerclage is an alternative to stainless steel cerclage fixation for stabilization of a humeral osteotomy during shoulder arthroplasty" 29 : e609-17, 2021

      24 Dein EJ, "A humerus fracture in a baseball pitcher after biceps tenodesis" 42 : 877-879, 2014

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼