      장기간의 유지관리 실패로 인해 파절된 임플란트 피개의치 재수복 증례 = Retreatment of fractured implant overdenture due to long-term maintenance failure

      한글로보기

      https://www.riss.kr/link?id=A105515645

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Periodontal and prosthodontic maintenance of implant overdenture is a very important factor for the long term success of the prosthesis and implants. Failure of maintenance can lead to prosthetic failure due to peri-implant bone loss and fracture and wear of the prosthesis or components. In this case, the existing gold milled bars were reconstructed with cobalt chrome milled bar in a manner that does not interfere with the external shape for the retreatment of fractured implant overdenture by maintenance failure. Two implants of mandible were selected strategically and the CM LOC attachments were connected to the two implants, and implant overdentures were fabricated. As a result, prosthesis with a functional and esthetic design that facilitates good hygiene management of the patient was delivered, which is advantageous for long term maintenance, and regular check-ups were scheduled for proper maintenance.
      번역하기

      Periodontal and prosthodontic maintenance of implant overdenture is a very important factor for the long term success of the prosthesis and implants. Failure of maintenance can lead to prosthetic failure due to peri-implant bone loss and fracture and ...

      Periodontal and prosthodontic maintenance of implant overdenture is a very important factor for the long term success of the prosthesis and implants. Failure of maintenance can lead to prosthetic failure due to peri-implant bone loss and fracture and wear of the prosthesis or components. In this case, the existing gold milled bars were reconstructed with cobalt chrome milled bar in a manner that does not interfere with the external shape for the retreatment of fractured implant overdenture by maintenance failure. Two implants of mandible were selected strategically and the CM LOC attachments were connected to the two implants, and implant overdentures were fabricated. As a result, prosthesis with a functional and esthetic design that facilitates good hygiene management of the patient was delivered, which is advantageous for long term maintenance, and regular check-ups were scheduled for proper maintenance.

      더보기

      참고문헌 (Reference)

      1 Doundoulakis JH, "The implant-supported overdenture as an alternative to the complete mandibular denture" 134 : 1455-1458, 2003

      2 Sanna A, "Successful outcome of splinted implants supporting a 'planned' maxillary overdenture: a retrospective evaluation and comparison with fixed full dental prostheses" 20 : 406-413, 2009

      3 van Kampen F, "Retention and postinsertion maintenance of bar-clip, ball and magnet attachments in mandibular implant overdenture treatment: an in vivo comparison after 3 months of function" 14 : 720-726, 2003

      4 Asvanund C, "Restoration of unfavorably positioned implants for a partially endentulous patient by using an overdenture retained with a milled bar and attachments: a clinical report" 91 : 6-10, 2004

      5 Becker W, "Replacement of maxillary and man- dibular molars with single endosseous implant restorations: a retrospective study" 74 : 51-55, 1995

      6 Osman RB, "Prosthodontic maintenance of maxillary implant overdentures: a systematic literature re- view" 25 : 381-391, 2012

      7 Andreiotelli M, "Prosthodontic complications with implant overdentures: a systematic literature review" 23 : 195-203, 2010

      8 Phoenix RD, "Lingualized occlusion revisited" 104 : 342-346, 2010

      9 Krennmair G, "Implantsupported mandibular overdentures retained with a milledbar: a retrospective study" 22 : 987-994, 2007

      10 Misch K, "Implant surgery complications: etiology and treatment" 17 : 159-168, 2008

      1 Doundoulakis JH, "The implant-supported overdenture as an alternative to the complete mandibular denture" 134 : 1455-1458, 2003

      2 Sanna A, "Successful outcome of splinted implants supporting a 'planned' maxillary overdenture: a retrospective evaluation and comparison with fixed full dental prostheses" 20 : 406-413, 2009

      3 van Kampen F, "Retention and postinsertion maintenance of bar-clip, ball and magnet attachments in mandibular implant overdenture treatment: an in vivo comparison after 3 months of function" 14 : 720-726, 2003

      4 Asvanund C, "Restoration of unfavorably positioned implants for a partially endentulous patient by using an overdenture retained with a milled bar and attachments: a clinical report" 91 : 6-10, 2004

      5 Becker W, "Replacement of maxillary and man- dibular molars with single endosseous implant restorations: a retrospective study" 74 : 51-55, 1995

      6 Osman RB, "Prosthodontic maintenance of maxillary implant overdentures: a systematic literature re- view" 25 : 381-391, 2012

      7 Andreiotelli M, "Prosthodontic complications with implant overdentures: a systematic literature review" 23 : 195-203, 2010

      8 Phoenix RD, "Lingualized occlusion revisited" 104 : 342-346, 2010

      9 Krennmair G, "Implantsupported mandibular overdentures retained with a milledbar: a retrospective study" 22 : 987-994, 2007

      10 Misch K, "Implant surgery complications: etiology and treatment" 17 : 159-168, 2008

      11 Watson CJ, "Implant complications and failures: the complete overdenture" 28 : 234- 8, 240, 2001

      12 Hong HR, "Effect of implant position, angulation, and attachment height on peri-implant bone stress associated with mandibular twoimplant overdentures: a finite element analysis" 27 : e69-e76, 2012

      13 김하영, "Attachment systems for mandibular implant overdentures: a systematic review" 대한치과보철학회 4 (4): 197-203, 2012

      14 Trakas T, "Attachment systems for implant retained overdentures: a literature review" 15 : 24-34, 2006

      15 Astrand P, "Astra Tech and Branemark system implants: a 5-year prospective study of marginal bone reactions" 15 : 413-420, 2004

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2026 평가예정 재인증평가 신청대상 (재인증)
      2020-01-01 평가 등재학술지 유지 (재인증) KCI등재
      2017-01-01 평가 등재학술지 유지 (계속평가) KCI등재
      2013-01-01 평가 등재 1차 FAIL (등재유지) KCI등재
      2010-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2009-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2009-01-01 평가 학술지 분리 (기타) KCI등재후보
      2007-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2004-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2003-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2001-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.22 0.22 0.2
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.21 0.21 0.353 0
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼