RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      직경이 작은 유압관로에서의 동특성

      한글로보기

      https://www.riss.kr/link?id=E689556

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

      This paper is primarily directed toward analyzing the frequency response in hydraulic pipe lines with a small diameter. The exact solution to the frequency response is obtained by using the complicated transfer function. The discrepancy with the exact and the approximate is small, so the approximation solution is adopted to compare the experimental result with the theoretical analysis.
      In this experiment, the input frequency was generated by the frequency generator with the ball valve and speed controller. In order to compare the theoretical wave forms with the experimental ones, the trace obtained from the oscilloscope is photographed. The diameter, the length of lines, and input pressure amplitude are varied to investigate their effects the experiment result show that the values of dimensionless parameter are very affected to the phase delay and guide response time in the design of pressure manifold to measure the pressure of hydraulic pipelines.
      번역하기

      This paper is primarily directed toward analyzing the frequency response in hydraulic pipe lines with a small diameter. The exact solution to the frequency response is obtained by using the complicated transfer function. The discrepancy with the exact...

      This paper is primarily directed toward analyzing the frequency response in hydraulic pipe lines with a small diameter. The exact solution to the frequency response is obtained by using the complicated transfer function. The discrepancy with the exact and the approximate is small, so the approximation solution is adopted to compare the experimental result with the theoretical analysis.
      In this experiment, the input frequency was generated by the frequency generator with the ball valve and speed controller. In order to compare the theoretical wave forms with the experimental ones, the trace obtained from the oscilloscope is photographed. The diameter, the length of lines, and input pressure amplitude are varied to investigate their effects the experiment result show that the values of dimensionless parameter are very affected to the phase delay and guide response time in the design of pressure manifold to measure the pressure of hydraulic pipelines.

      더보기

      목차 (Table of Contents)

      • 1. 서론
      • 2. 이론해석
      • 3. 실험
      • 1. 서론
      • 2. 이론해석
      • 3. 실험
      • 4. 결과 및 고찰
      • 4. 결론
      • 5. 참고문헌
      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼