The dynamic resilient modulus tests to determine the $M_R$ of the soils require expensive equipments and well trained personnels to obtain reliable test results. These problems inherent in the dynamic resilient modulus testing have been realized as ma...
The dynamic resilient modulus tests to determine the $M_R$ of the soils require expensive equipments and well trained personnels to obtain reliable test results. These problems inherent in the dynamic resilient modulus testing have been realized as major negative factors to hinder the $M_R$ test from being practically implemented as a routine test. In this regard. it is highly desirable to develop a simpler alternative testing method incorporating inexpensive equipments and easy-to-perform testing procedures. Developed in this study is an alternative $M_R$ test method based on statically repeated loading scheme utilizing the standard static triaxial test equipments. Applicability and limitations of the developed static $M_R$ testing method are investigated for typical subgrade soils in Korea.