RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      SCI SCIE SCOPUS

      Estimation of hysteresis loss in Sm<sub>1</sub>Ba<sub>2</sub>Cu<sub>3</sub>O<sub>7&#x2212;δ</sub> coated conductor via scanning Hall probe measurements with simultaneously applied field and current

      한글로보기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      <P>The hysteresis loss in a Sm<SUB>1</SUB>Ba<SUB>2</SUB>Cu<SUB>3</SUB>O<SUB>7−δ</SUB> coated conductor was estimated from magnetic field profiles measured by the scanning Hall probe me...

      <P>The hysteresis loss in a Sm<SUB>1</SUB>Ba<SUB>2</SUB>Cu<SUB>3</SUB>O<SUB>7−δ</SUB> coated conductor was estimated from magnetic field profiles measured by the scanning Hall probe method. Current, <I>I</I><SUB>a</SUB>, and magnetic field, <I>B</I><SUB>a</SUB>, were applied simultaneously; <I>B</I><SUB>a</SUB> was applied in the normal direction with respect to the tape surface. <I>B</I><SUB>a</SUB> and <I>I</I><SUB>a</SUB> were varied from <I>B</I><SUB>peak</SUB> to −<I>B</I><SUB>peak</SUB> and from <I>I</I><SUB>peak</SUB> to −<I>I</I><SUB>peak</SUB>, respectively, with the ratio α = <I>I</I><SUB>a</SUB>/<I>B</I><SUB>a</SUB> fixed during the variation. Three values of α were taken for the three load lines. The values of <I>B</I><SUB>peak</SUB>/<I>I</I><SUB>peak</SUB> were varied from 0 mT/0 A to 10.7 mT/116 A, 99.1 mT/50 A, and 298.2 mT/46.1 A, respectively, for the three load lines. From the measured values of magnetic field profiles, the current profiles were calculated by the iterative inversion method. From the current profiles, the flux density profiles and the hysteresis loss, <I>Q</I>, were then calculated for various values of <I>I</I><SUB>peak</SUB>(= α<I>B</I><SUB>peak</SUB>) in each load line. The results were compared with theoretical calculations based on Brandt’s model. When <I>B</I><SUB>peak</SUB> was about 300 mT, the estimated values of <I>Q</I> were several times smaller than the theoretical values of <I>Q</I> with the self-field <I>I</I><SUB>c0</SUB>. The low value of <I>Q</I> in this case is due to the field dependent <I>I</I><SUB>c</SUB> and the saturation effect of the current profiles, which results in significant reduction of the induced magnetic moment, <I>M</I>. </P>

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼