      Driven-Right-Leg 회로 개선에 의한 접지접촉 간섭파 제거에 관한 연구 = A Study on Reduction of Ground Contact Interference by Driven-Right-Leg Circuit Modification

      한글로보기

      https://www.riss.kr/link?id=A19616456

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Abstract - This study describes a method developed to reduce electromagnetic interference induced to bio-potential ECG amplifier with the Driven -Right-Leg circuit when human body contacts earth ground, accidentally. Since the contact between body and earth ground disturbs the presumed operation of the Driven-Right-Leg circuit, the ECG signal includes serious interference level, preventing ECG signal analysis by formal methods. To decrease the current flow to the Driven-Right-Leg circuit, a resistor is added between the output of the circuit and the amplifier common. Experiment has shown that the modified circuit reduces the interference level significantly both during body contact to earth ground (~1/5) and during without contact(~1/2).
      번역하기

      Abstract - This study describes a method developed to reduce electromagnetic interference induced to bio-potential ECG amplifier with the Driven -Right-Leg circuit when human body contacts earth ground, accidentally. Since the contact between body and...

      Abstract - This study describes a method developed to reduce electromagnetic interference induced to bio-potential ECG amplifier with the Driven -Right-Leg circuit when human body contacts earth ground, accidentally. Since the contact between body and earth ground disturbs the presumed operation of the Driven-Right-Leg circuit, the ECG signal includes serious interference level, preventing ECG signal analysis by formal methods. To decrease the current flow to the Driven-Right-Leg circuit, a resistor is added between the output of the circuit and the amplifier common. Experiment has shown that the modified circuit reduces the interference level significantly both during body contact to earth ground (~1/5) and during without contact(~1/2).

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼