RISS 학술연구정보서비스

검색

인기 검색어

    다국어 입력

    http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

    변환된 중국어를 복사하여 사용하시면 됩니다.

    예시)
    • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
    • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
    닫기
    KCI등재 SCI SCIE SCOPUS

    Development of a Multi-Channel Signal Optimizer for a Compton Camera System

    한글로보기

    https://www.riss.kr/link?id=A104206440

    • 0

      상세조회
    • 0

      다운로드
    서지정보 열기
    • 내보내기
    • 내책장담기
    • 공유하기
      • URL 복사
    • 오류접수
    인용문이 복사되었습니다.

    부가정보

    다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

    A multi-channel differential-to-single-ended signal optimizer has been developed for application in a low-energy Compton camera system. The developed multi-channel signal optimizer enhanced the signal-to-noise ratio of the whole system compared to the case in which a simple resistive network converter was used. In order to verify the performance of the developed signal optimizer, we performed an energy measurement for gamma rays emitted from 241Am, 133Ba and 137Cs standard sources by using a double-sided silicon strip detector. The energy resolution of 19 keV, full width at half maximum, was obtained by fitting a 59.6-keV gamma-ray peak, and the energy threshold level of time pick-up circuits was determined to be 35 keV by comparing the measured energy spectrum with a simulated one obtained with a Monte Carlo code. The obtained energy resolution and the energy threshold level show that the developed signal optimizer can effectively enhance the signal-to-noise ratio for multi-channel electronics and enables us to construct a Compton camera system combined with low-cost commercially-available multi-channel electronics.
    번역하기

    A multi-channel differential-to-single-ended signal optimizer has been developed for application in a low-energy Compton camera system. The developed multi-channel signal optimizer enhanced the signal-to-noise ratio of the whole system compared to the...

    A multi-channel differential-to-single-ended signal optimizer has been developed for application in a low-energy Compton camera system. The developed multi-channel signal optimizer enhanced the signal-to-noise ratio of the whole system compared to the case in which a simple resistive network converter was used. In order to verify the performance of the developed signal optimizer, we performed an energy measurement for gamma rays emitted from 241Am, 133Ba and 137Cs standard sources by using a double-sided silicon strip detector. The energy resolution of 19 keV, full width at half maximum, was obtained by fitting a 59.6-keV gamma-ray peak, and the energy threshold level of time pick-up circuits was determined to be 35 keV by comparing the measured energy spectrum with a simulated one obtained with a Monte Carlo code. The obtained energy resolution and the energy threshold level show that the developed signal optimizer can effectively enhance the signal-to-noise ratio for multi-channel electronics and enables us to construct a Compton camera system combined with low-cost commercially-available multi-channel electronics.

    더보기

    참고문헌 (Reference)

    1 R. W. Todd, 251 : 132-, 1974

    2 M. Singh, 10 : 421-, 1983

    3 T. C onka Nurdan, 523 : 435-, 2004

    4 J. H. Lee, 758 : 150-, 2005

    5 J. H. Lee, 746 : 639-, 2004

    6 D. Meier, 49 : 812-, 2002

    7 S. H. Ahn, 571 : 251-, 2007

    8 N. Y. Kim, 47 : 737-, 2005

    9 이춘식, "Stack형 컴프턴 카메라의 영상특성에 대한 몬테카를로 모사연구" 한국물리학회 53 (53): 130-126, 2006

    10 H. Y. Cho, "Pulse Shape Analysis of Induced Charges in a Segmented Germanium Detector by Using the Weighting Potential Method" 한국물리학회 45 (45): 1485-1489, 2004

    1 R. W. Todd, 251 : 132-, 1974

    2 M. Singh, 10 : 421-, 1983

    3 T. C onka Nurdan, 523 : 435-, 2004

    4 J. H. Lee, 758 : 150-, 2005

    5 J. H. Lee, 746 : 639-, 2004

    6 D. Meier, 49 : 812-, 2002

    7 S. H. Ahn, 571 : 251-, 2007

    8 N. Y. Kim, 47 : 737-, 2005

    9 이춘식, "Stack형 컴프턴 카메라의 영상특성에 대한 몬테카를로 모사연구" 한국물리학회 53 (53): 130-126, 2006

    10 H. Y. Cho, "Pulse Shape Analysis of Induced Charges in a Segmented Germanium Detector by Using the Weighting Potential Method" 한국물리학회 45 (45): 1485-1489, 2004

    11 Ju Hahn Lee, "Monte Carlo Study on the Imaging Resolution and Sensitivity of a Compton Camera" 한국물리학회 49 (49): 97-102, 2006

    더보기

    분석정보

    View

    상세정보조회

    0

    Usage

    원문다운로드

    0

    대출신청

    0

    복사신청

    0

    EDDS신청

    0

    동일 주제 내 활용도 TOP

    더보기

    주제

    연도별 연구동향

    연도별 활용동향

    연관논문

    연구자 네트워크맵

    공동연구자 (7)

    유사연구자 (20) 활용도상위20명

    인용정보 인용지수 설명보기

    학술지 이력

    학술지 이력
    연월일 이력구분 이력상세 등재구분
    2023 평가 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
    2020-01-01 등재 등재학술지 유지 (해외등재 학술지 평가) KCI등재
    2011-01-01 등재 등재학술지 유지 (등재유지) KCI등재
    2009-01-01 등재 등재학술지 유지 (등재유지) KCI등재
    2007-01-01 등재 SCI 등재 (등재유지) KCI등재
    2005-01-01 등재 등재학술지 유지 (등재유지) KCI등재
    2002-07-01 등재 등재학술지 선정 (등재후보2차) KCI등재
    2000-01-01 등재 등재후보학술지 선정 (신규평가) KCI등재후보
    더보기

    학술지 인용정보

    학술지 인용정보
    기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
    2016 0.47 0.15 0.31
    KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
    0.26 0.2 0.26 0.03
    더보기

    이 자료와 함께 이용한 RISS 자료

    나만을 위한 추천자료

    해외이동버튼