      요추간판 수핵탈출증 수술환자의 체간부 굴근 및 신근의 등속성 운동 평가  :  Isokinetic Evaluation of the Trunk Flexors and Extensors of Operated Laminectomy & Disectomy Patients

      한글로보기

      https://www.riss.kr/link?id=A75015407

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Isokinetic exercise is dynamic, but the spped of movement must be regulated so that the resistance is in ratio to the force applied at each point throughout the full range of motion. The purpose of this study is to comparise with trunk flexors & extensors of isokinetic evaluation of pre-exercise and post-exercise in operated laminectomy & disectomy patients. 7 subjects were examined at 120˚/sec and 60˚/sec each 15 days.
      The results were as follows;
      1. Peak torque of extensors on 60˚/sec showed significant difference statistically(p<0.05), but peak torque of flexors on 60˚/sec showed no significant difference statistically.
      2. Trunk flexors/extensors ratio of peak torque of 60˚/sec showed no significant difference statistically.
      3. Peak torque % B.W of extensors on 60˚/sec showed significant difference statistically(p<0.05), but peak torque % B.W of flexors on 60。/sec showed no significant difference statistically.
      4. TAE of extensors on 60。/sec showed significant difference statistically (p<0.05), but TAE of flexors on 60˚/sec showed no significant difference.
      5. Total work of flexors & extensors on 60˚/sec showed significant difference statistically.(p<0.05).
      6. Average power of flexors & extensors on 120˚/sec showed significant difference statistically(p<0.05).
      7. Endurance ratio of flexors & extensors on 120˚/sec showed no significant difference statistically.
      8. Set total work of flexors & extensors on 120˚/sec showed significant difference statistically(p<0.05).
      9. TAE of extensors on 120˚/sec showed significant difference statistically(p<0.05), TAE of flexors on 120˚/sec showed no significant difference statistically.
      10. Total work of flexors & extensors on 120˚/sec showed significant difference statistically(p<0.05).
      번역하기

      Isokinetic exercise is dynamic, but the spped of movement must be regulated so that the resistance is in ratio to the force applied at each point throughout the full range of motion. The purpose of this study is to comparise with trunk flexors & exten...

      Isokinetic exercise is dynamic, but the spped of movement must be regulated so that the resistance is in ratio to the force applied at each point throughout the full range of motion. The purpose of this study is to comparise with trunk flexors & extensors of isokinetic evaluation of pre-exercise and post-exercise in operated laminectomy & disectomy patients. 7 subjects were examined at 120˚/sec and 60˚/sec each 15 days.
      The results were as follows;
      1. Peak torque of extensors on 60˚/sec showed significant difference statistically(p<0.05), but peak torque of flexors on 60˚/sec showed no significant difference statistically.
      2. Trunk flexors/extensors ratio of peak torque of 60˚/sec showed no significant difference statistically.
      3. Peak torque % B.W of extensors on 60˚/sec showed significant difference statistically(p<0.05), but peak torque % B.W of flexors on 60。/sec showed no significant difference statistically.
      4. TAE of extensors on 60。/sec showed significant difference statistically (p<0.05), but TAE of flexors on 60˚/sec showed no significant difference.
      5. Total work of flexors & extensors on 60˚/sec showed significant difference statistically.(p<0.05).
      6. Average power of flexors & extensors on 120˚/sec showed significant difference statistically(p<0.05).
      7. Endurance ratio of flexors & extensors on 120˚/sec showed no significant difference statistically.
      8. Set total work of flexors & extensors on 120˚/sec showed significant difference statistically(p<0.05).
      9. TAE of extensors on 120˚/sec showed significant difference statistically(p<0.05), TAE of flexors on 120˚/sec showed no significant difference statistically.
      10. Total work of flexors & extensors on 120˚/sec showed significant difference statistically(p<0.05).

      더보기

      목차 (Table of Contents)

      • ABSTRACT = 1
      • 서론 = 2
      • 연구의 의의 = 2
      • 연구가설 = 2
      • 용어의 정의 = 3
      • ABSTRACT = 1
      • 서론 = 2
      • 연구의 의의 = 2
      • 연구가설 = 2
      • 용어의 정의 = 3
      • 연구대상 및 방법 = 3
      • 연구대상 = 3
      • 연구방법 = 3
      • 연구결과 = 4
      • 고찰 = 8
      • 결론 = 9
      • 참고문헌 = 10
      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼