RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재

      건물형 태양광발전시스템의 설치조건에 따른 어레이/인버터 용량 비율 상한의 세분화 타당성 평가

      한글로보기

      https://www.riss.kr/link?id=A108982420

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Purpose: In the Republic of Korea, the upper limit for the DC/AC ratio of photovoltaic(PV) systems is conventionally set at 105%, irrespective of installation conditions, such as azimuth and inclination. The upper limit of the DC/AC ratio that does no...

      Purpose: In the Republic of Korea, the upper limit for the DC/AC ratio of photovoltaic(PV) systems is conventionally set at 105%, irrespective of installation conditions, such as azimuth and inclination. The upper limit of the DC/AC ratio that does not consider these features causes negative impacts on the economics and performance of building PV systems. Therefore, this study evaluates the feasibility of segmenting the upper limit of the DC/AC ratio based on diverse installation conditions to address these issues. Method: To explore this study, a building PV system model with a DC/AC ratio of 104% was developed using a simulation program. With the developed model, an analysis of the operational maximum array power ratio to the designed array power for various installation conditions is carried out. In addition, this study also examined the effects of increasing the DC/AC ratio on performance under specified installation conditions. Result: Based on results from analyzing the operational maximum array power ratio to the designed array power, findings indicated that the south-inclined plane achieved approximately 90%, while the east-to-west vertical surfaces ranged between 66% and 80%. Further, the evaluation of the impact of increasing the DC/AC ratio under various installation conditions revealed that augmenting the DC/AC ratio to certain specified conditions notably enhanced both power generation and overall system performance. These results demonstrate that PV systems with identical array capacities can yield significantly different maximum powers based on installation conditions. This study underscores the importance of condition-specific segmentation for determining the upper limit of the DC/AC ratio.

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼