Analysis and experiment are performed to investigate the thermal performance of a<br/> heat pipe with screen meshed wick. The heat pipe was designed in 200 screen meshs, 500 mm<br/> length and 12mm O.D tube of copper, water as working flui...
http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
https://www.riss.kr/link?id=A75897206
2003
Korean
550
학술저널
7-12(6쪽)
0
상세조회0
다운로드다국어 초록 (Multilingual Abstract)
Analysis and experiment are performed to investigate the thermal performance of a<br/> heat pipe with screen meshed wick. The heat pipe was designed in 200 screen meshs, 500 mm<br/> length and 12mm O.D tube of copper, water as working flui...
Analysis and experiment are performed to investigate the thermal performance of a<br/>
heat pipe with screen meshed wick. The heat pipe was designed in 200 screen meshs, 500 mm<br/>
length and 12mm O.D tube of copper, water as working fluid and nitrogen as non-condensible gas.<br/>
Heat pipe used in this study has evaporator, condenser and adiabatic section, respectively.<br/>
Experimental data of wall temperature distribution along axial length is presented for heat transport<br/>
capacity, condensor cooling water temperature change, degrees of an inclination angle, and operating<br/>
temperature.