RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      7mm 루버 핀-관 열교환기의 열전달 및 압력강하 특성에 관한 실험적 연구 = Experimental study heat transfer and friction characteristics of 7mm louver finned-tube exchangers

      한글로보기

      https://www.riss.kr/link?id=E805133

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

      The purpose of this study was to investigate the heat transfer and friction characteristics of 7mm louver finned-tube exchangers. Evaporators used to the present study were the finned-tube type. Tested finned-tube evaporators was changed configuration parameters such as fin type, row number, tube diameter. To control the temperature, velocity and humidity of inlet air flow, a heat wind tunnel was used. The experimental results show that the heat transfer and friction of 7mm evaporator(3 row) are more higher above 30% than those of 9.52mm evaporator. And it is observed that the heat transfer and friction performance of the evaporator with louver fin was higher above 5%,compared with those of slit fin.
      번역하기

      The purpose of this study was to investigate the heat transfer and friction characteristics of 7mm louver finned-tube exchangers. Evaporators used to the present study were the finned-tube type. Tested finned-tube evaporators was changed configuration...

      The purpose of this study was to investigate the heat transfer and friction characteristics of 7mm louver finned-tube exchangers. Evaporators used to the present study were the finned-tube type. Tested finned-tube evaporators was changed configuration parameters such as fin type, row number, tube diameter. To control the temperature, velocity and humidity of inlet air flow, a heat wind tunnel was used. The experimental results show that the heat transfer and friction of 7mm evaporator(3 row) are more higher above 30% than those of 9.52mm evaporator. And it is observed that the heat transfer and friction performance of the evaporator with louver fin was higher above 5%,compared with those of slit fin.

      더보기

      목차 (Table of Contents)

      • 1. 서론
      • 2. 실험장치 및 실험방법
      • 3. Data reduction
      • 4. 실험결과
      • 5. 결론
      • 1. 서론
      • 2. 실험장치 및 실험방법
      • 3. Data reduction
      • 4. 실험결과
      • 5. 결론
      • 참고문헌
      더보기