Two-points response method for the parameter evaluation of the axial dispersion model was investigated with tracer response curves obtained from a liquid flow through a vertical cylinderical column packed with ceramic spheres.
The analysis of respon...
Two-points response method for the parameter evaluation of the axial dispersion model was investigated with tracer response curves obtained from a liquid flow through a vertical cylinderical column packed with ceramic spheres.
The analysis of response curves was performed with the exponential approximation of the tail part from the point at which the tracer concentration dropped to 1/3~1/15 of maximum concentration of the response curve according to flow conditions.
Model paramenters evaluated through the moment method showed much worse fitness than those evaluated through the transfer function method and the weighted-moment method performed with appropriate range of Laplace parameters.
The model parameters evaluated with Laplace parameter in the range of 4≤τs≤7for the transfer function method and 2≤τs≤5 for the weighted-moment method were nearly equal.