Spent ion-exchanged resin generated from various purification systems in CANDU reactor was contaminated with high activity of $^{14}C$ radionuclide. This paper describes the results of fundamental study to develop the applicable technology for the tre...
Spent ion-exchanged resin generated from various purification systems in CANDU reactor was contaminated with high activity of $^{14}C$ radionuclide. This paper describes the results of fundamental study to develop the applicable technology for the treatment of this spent resin. Based on the adsorption capacity of inactive $HCO_3$ ion and other anions on IRN-150 mixed resin, the removal characteristics of $HCO_3$ ion adsorbed on to IRN-150 by various stripping solutions were evaluated. Maximum adsorption amount of the $HCO_3$ ion onto IRN-150 raw resin was about 11 mg-C/g-resin which agrees with the theoretical adsorption amount of this resin. Adsorption affinity of various anions such as $CS,\;CO,\;Na\;NH_4$ was analyzed in single and multi-component systems. From the results of removal characteristics of the $HCO_3$ ion adsorbed on IRN-150 by various stripping solutions, $NH_4H_2PO_4$ stripping solution is more effective than $NaNO_3,\;Na_3PO_3$ solutions for the complete removal of $^{14}C$ radionuclide from the IRN-150 spent resin.