      성층화 Lumped Thermal Model을 이용한 VAV 시스템 급기제어 시뮬레이션 = Simulation of Supply Air Control in a VAV System Using a Stratified Lumped Thermal Model

      한글로보기

      https://www.riss.kr/link?id=E807319

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      The present study concerns the simulation of supply-air control in a variable air volume (VAV) system. A stratified lumped thermal model (multi-zone model) is suggested to predict thermal response of an air-conditioned space. The effects of various thermal parameters such as the cooling system capacity, the thermal mass of air-conditioned space, the time delay of thermal effect, and the building envelope heat transmission are investigated in detail. Further, the influence of control parameters, PI control factor and the sensor location on a VAV system is quantitatively delineated. The results obtained show that the previous homogeneous lumped thermal model (1-zone model) can predict a significantly different thermal response in the air-conditioned space according to the sensor location.

      번역하기

      The present study concerns the simulation of supply-air control in a variable air volume (VAV) system. A stratified lumped thermal model (multi-zone model) is suggested to predict thermal response of an air-conditioned space. The effects of various th...

      The present study concerns the simulation of supply-air control in a variable air volume (VAV) system. A stratified lumped thermal model (multi-zone model) is suggested to predict thermal response of an air-conditioned space. The effects of various thermal parameters such as the cooling system capacity, the thermal mass of air-conditioned space, the time delay of thermal effect, and the building envelope heat transmission are investigated in detail. Further, the influence of control parameters, PI control factor and the sensor location on a VAV system is quantitatively delineated. The results obtained show that the previous homogeneous lumped thermal model (1-zone model) can predict a significantly different thermal response in the air-conditioned space according to the sensor location.

      더보기

      목차 (Table of Contents)

      • 1. 서론
      • 2. 공조 공간 모델링
      • 3. 결과 및 토의
      • 4. 결론
      • 참고문헌
      • 1. 서론
      • 2. 공조 공간 모델링
      • 3. 결과 및 토의
      • 4. 결론
      • 참고문헌