RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      C형간염 진단을 위한 중합효소연쇄반응의 임상적 유용성 검토 = Clinical Application of Polymerase Chain Reaction for the Diagnosis of Hepatitis C Virus Infection

      한글로보기

      https://www.riss.kr/link?id=A40038500

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Current serologic tests for the detection of antibody lo hepatitis C virus (anti-HCV) by enzyme immunoassay (EIA) produce occasional false positive reactions and do not provide useful data about the previous status of antibody formation. So, supplementary tests are necessary. Recently, the application of Polymerase Chain Reaction (PCR) for the detection of HCV RNA has been reported for this confirmatory purpose. The authors evaluated the clinical usefulness of this PCR assay as a routine laboratory diagnostic test for the detection of HCV infection.
      In this study, HCV-PCR assays were performed for 80 samples of liver disease, 27 samples of hemodialysis, and 40 samples of healthy blood donor. These assays utilized nested reverse transcriplase-PCR(RT-PCR) with two pairs of oligonucleotide primers (40S, NTA1, 80S, 300A) based on the 5'-UTR regions. The results were compared to those of tests for anti-HCV by EIA and another two primer pairs (#32, #36, #33, #48). Clinical data including ALT level were also compared.
      The results are as follows:
      HCV RNA was detected by PCR in 44/80(55%) cases. The comparison of results between PCR and EIA showed concordance in 48/72(67%) cases. Discordance that is negative by PCR but positive by EIA or positive by PCR but negative by EIA, occurred in 18/72(25%) cases and 6/72(8%) cases, respectively. In 6/72(8%) cases of positive by PCR but negative by EIA, the mean value of ALT was 145.3 IU/L, whereas the mean value of ALT was 70 IU/L in 16/72(23%) cases in which both tests were negative. The 40 healthy normal blood donors were all PCR negative. 12/27(44%) cases of hemodialysis patients were positive by PCR, but 9/12(75%) cases were negative by EIA. The comparison between two different primer pair sets showed concordance in 34/40 (85%) and discordance in 6/40 (15%) cases, respectively.
      In conclusion, PCR assay by simplified nested RT-PCR for the detection of HCV RNA can be a valuable diagnostic tool for the early detection of HCV infection and viremia. But further studies involving more clinical cases, in-depth analysis of possible factors causing false negative or positive reactions, and investigation of the technical aspects of specimen handling should be performed.
      번역하기

      Current serologic tests for the detection of antibody lo hepatitis C virus (anti-HCV) by enzyme immunoassay (EIA) produce occasional false positive reactions and do not provide useful data about the previous status of antibody formation. So, supplemen...

      Current serologic tests for the detection of antibody lo hepatitis C virus (anti-HCV) by enzyme immunoassay (EIA) produce occasional false positive reactions and do not provide useful data about the previous status of antibody formation. So, supplementary tests are necessary. Recently, the application of Polymerase Chain Reaction (PCR) for the detection of HCV RNA has been reported for this confirmatory purpose. The authors evaluated the clinical usefulness of this PCR assay as a routine laboratory diagnostic test for the detection of HCV infection.
      In this study, HCV-PCR assays were performed for 80 samples of liver disease, 27 samples of hemodialysis, and 40 samples of healthy blood donor. These assays utilized nested reverse transcriplase-PCR(RT-PCR) with two pairs of oligonucleotide primers (40S, NTA1, 80S, 300A) based on the 5'-UTR regions. The results were compared to those of tests for anti-HCV by EIA and another two primer pairs (#32, #36, #33, #48). Clinical data including ALT level were also compared.
      The results are as follows:
      HCV RNA was detected by PCR in 44/80(55%) cases. The comparison of results between PCR and EIA showed concordance in 48/72(67%) cases. Discordance that is negative by PCR but positive by EIA or positive by PCR but negative by EIA, occurred in 18/72(25%) cases and 6/72(8%) cases, respectively. In 6/72(8%) cases of positive by PCR but negative by EIA, the mean value of ALT was 145.3 IU/L, whereas the mean value of ALT was 70 IU/L in 16/72(23%) cases in which both tests were negative. The 40 healthy normal blood donors were all PCR negative. 12/27(44%) cases of hemodialysis patients were positive by PCR, but 9/12(75%) cases were negative by EIA. The comparison between two different primer pair sets showed concordance in 34/40 (85%) and discordance in 6/40 (15%) cases, respectively.
      In conclusion, PCR assay by simplified nested RT-PCR for the detection of HCV RNA can be a valuable diagnostic tool for the early detection of HCV infection and viremia. But further studies involving more clinical cases, in-depth analysis of possible factors causing false negative or positive reactions, and investigation of the technical aspects of specimen handling should be performed.

      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼