RISS 학술연구정보서비스

검색

인기 검색어

    다국어 입력

    http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

    변환된 중국어를 복사하여 사용하시면 됩니다.

    예시)
    • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
    • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
    닫기
    KCI등재

    전력전자 부하 지표와 물리내재 LSTM을 활용한 스푸핑 내성 차압 제어 = Spoofing-Resistant Differential Pressure Control using Power Electronics Load Indicators and Physics-Informed LSTM

    한글로보기

    https://www.riss.kr/link?id=A110091459

    • 0

      상세조회
    • 0

      다운로드
    서지정보 열기
    • 내보내기
    • 내책장담기
    • 공유하기
    • 오류접수

    부가정보

    다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

    Maintaining room–hallway differential pressure (ΔP) is essential for infection control (negative-pressure isolation) and smoke backflow prevention (positively pressurized zones). Sensor spoofing—bias, drift, delay, and replay—can mislead controllers, causing unsafe over/under-pressure and excessive fan burden. This paper specifies a physics-informed LSTM (PI-LSTM) residual detector whose loss embeds mass balance and fan laws, and analyzes a lightweight confusion-index (CI) proxy aggregating fan power, pressure deviation, and flow imbalance. A small-chamber HVAC simulator generates physically credible synthetic datasets (door-leak toggling, low-frequency wind offsets, sensor noise, parameter uncertainty). On this baseline, a simple residual score exhibits clear separation between normal and attacked segments, with strong ROC/PR characteristics, while the CI consistently rises during attacks, summarizing increased system burden. As a simulation-only baseline study, this work provides a reproducible evaluation path and motivates future closed-loop CI-guided mitigation and power-electronics-derived stress-metric validation on hardware.
    번역하기

    Maintaining room–hallway differential pressure (ΔP) is essential for infection control (negative-pressure isolation) and smoke backflow prevention (positively pressurized zones). Sensor spoofing—bias, drift, delay, and replay—can mislead contro...

    Maintaining room–hallway differential pressure (ΔP) is essential for infection control (negative-pressure isolation) and smoke backflow prevention (positively pressurized zones). Sensor spoofing—bias, drift, delay, and replay—can mislead controllers, causing unsafe over/under-pressure and excessive fan burden. This paper specifies a physics-informed LSTM (PI-LSTM) residual detector whose loss embeds mass balance and fan laws, and analyzes a lightweight confusion-index (CI) proxy aggregating fan power, pressure deviation, and flow imbalance. A small-chamber HVAC simulator generates physically credible synthetic datasets (door-leak toggling, low-frequency wind offsets, sensor noise, parameter uncertainty). On this baseline, a simple residual score exhibits clear separation between normal and attacked segments, with strong ROC/PR characteristics, while the CI consistently rises during attacks, summarizing increased system burden. As a simulation-only baseline study, this work provides a reproducible evaluation path and motivates future closed-loop CI-guided mitigation and power-electronics-derived stress-metric validation on hardware.

    더보기

    동일학술지(권/호) 다른 논문

    분석정보

    View

    상세정보조회

    0

    Usage

    원문다운로드

    0

    대출신청

    0

    복사신청

    0

    EDDS신청

    0

    동일 주제 내 활용도 TOP

    더보기

    주제

    연도별 연구동향

    연도별 활용동향

    연관논문

    연구자 네트워크맵

    공동연구자 (7)

    유사연구자 (20) 활용도상위20명

    이 자료와 함께 이용한 RISS 자료

    나만을 위한 추천자료

    해외이동버튼