      어려운 기도에서 굴곡성 기관지경을 사용한 경비 기관내삽관 시 효과적인 비출혈 제거 —증례보고— = Effective removal of epistaxis during nasotracheal intubation utilizing a fiberoptic scope in a difficult airway −A case report−

      한글로보기

      https://www.riss.kr/link?id=A104327813

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Nasal bleeding related to nasal trauma is the most common complication of nasotracheal intubation with a fiberoptic scope. When nasotracheal intubation with a fiberoptic scope is performed, profuse bleeding from the nasal cavity makes it difficult to handle a fiberoptic scope and may cause a hypoxemia. So when nasal bleeding occurs, it is important to suction the nasal cavity for easy handling of a fiberoptic scope. But, it may be difficult to suction in a nasal cavity with a fiberoptic suction port only. We report a patient with nasal bleeding following nasotracheal intubation with a fiberoptic scope because of articular trismus, and successful nasotracheal intubation utilizing a fiberoptic scope by suctioning with an extra suction apparatus.
      번역하기

      Nasal bleeding related to nasal trauma is the most common complication of nasotracheal intubation with a fiberoptic scope. When nasotracheal intubation with a fiberoptic scope is performed, profuse bleeding from the nasal cavity makes it difficult to...

      Nasal bleeding related to nasal trauma is the most common complication of nasotracheal intubation with a fiberoptic scope. When nasotracheal intubation with a fiberoptic scope is performed, profuse bleeding from the nasal cavity makes it difficult to handle a fiberoptic scope and may cause a hypoxemia. So when nasal bleeding occurs, it is important to suction the nasal cavity for easy handling of a fiberoptic scope. But, it may be difficult to suction in a nasal cavity with a fiberoptic suction port only. We report a patient with nasal bleeding following nasotracheal intubation with a fiberoptic scope because of articular trismus, and successful nasotracheal intubation utilizing a fiberoptic scope by suctioning with an extra suction apparatus.

      더보기

      참고문헌 (Reference)

      1 Lu PP, "Softened endothracheal tube reduces the incidence and severity of epistaxis following nasotracheal intubation" 36 : 193-197, 1998

      2 Wright PJ, "Nasotracheal intubation: another approach" 41 : 1057-1058, 1986

      3 Morimoto Y, "Nasotracheal intubation under curve-tipped suction catheter guidance reduces epistaxis" 53 : 295-298, 2006

      4 Benumof JL, "Management of the difficult airway" 23 : 589-591, 1994

      5 O'Hanlon J, "Epistaxis and nasotracheal intubation- prevention with vasoconstrictor spray" 163 : 58-60, 1994

      6 Tintinalli JE, "Complications of nasotracheal intubation" 10 : 142-144, 1981

      7 Holdgaard HO, "Complications and late sequelae following nasotracheal intubation" 37 : 475-480, 1993

      8 Scamman FL, "An unusual complication of nasotracheal intubation" 59 : 352-353, 1983

      9 Boysen K, "An unusual case of nasotracheal tube occlusion" 40 : 1024-, 1985

      10 Kihara S, "A silicone-based wire-reinforced tracheal tube with a hemispherical bevel reduces nasal morbidity for nasotracheal intubation" 97 : 1488-1491, 2003

      1 Lu PP, "Softened endothracheal tube reduces the incidence and severity of epistaxis following nasotracheal intubation" 36 : 193-197, 1998

      2 Wright PJ, "Nasotracheal intubation: another approach" 41 : 1057-1058, 1986

      3 Morimoto Y, "Nasotracheal intubation under curve-tipped suction catheter guidance reduces epistaxis" 53 : 295-298, 2006

      4 Benumof JL, "Management of the difficult airway" 23 : 589-591, 1994

      5 O'Hanlon J, "Epistaxis and nasotracheal intubation- prevention with vasoconstrictor spray" 163 : 58-60, 1994

      6 Tintinalli JE, "Complications of nasotracheal intubation" 10 : 142-144, 1981

      7 Holdgaard HO, "Complications and late sequelae following nasotracheal intubation" 37 : 475-480, 1993

      8 Scamman FL, "An unusual complication of nasotracheal intubation" 59 : 352-353, 1983

      9 Boysen K, "An unusual case of nasotracheal tube occlusion" 40 : 1024-, 1985

      10 Kihara S, "A silicone-based wire-reinforced tracheal tube with a hemispherical bevel reduces nasal morbidity for nasotracheal intubation" 97 : 1488-1491, 2003

      11 Mallampati SR, "A clinical sign to predict difficult tracheal intubation: a prospective study" 32 : 429-434, 1985

      12 Watanabe S, "A "bubble-tip" (Airguide) tracheal tube system: its effects on incidence of epistaxis and ease of tube advancement in the subglottic region during nasotracheal intubation" 78 : 1140-1143, 1994

      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2013-11-27 학회명변경 한글명 : 대한마취과학회 -> 대한마취통증의학회 KCI등재
      2011-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2010-07-20 학술지명변경 한글명 : 대한마취과학회지 -> Korean Journal of Anesthesiology KCI등재
      2009-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2007-01-01 평가 등재 1차 FAIL (등재유지) KCI등재
      2004-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2003-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2001-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.09 0.09 0.1
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.09 0.09 0.27 0.01
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼