RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCIE SCOPUS

      Association Between Subcutaneous Implantable Cardioverter Defibrillator Preimplantation Screening and the Response to Cardiac Resynchronization Therapy

      한글로보기

      https://www.riss.kr/link?id=A107141839

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Background and Objectives: Preimplantation QRS-T morphology screening (TMS) is a composite tool for selecting subcutaneous implantable cardioverter defibrillator (S-ICD) candidates. However, its role in predicting the patient's response to cardiac res...

      Background and Objectives: Preimplantation QRS-T morphology screening (TMS) is a composite tool for selecting subcutaneous implantable cardioverter defibrillator (S-ICD) candidates. However, its role in predicting the patient's response to cardiac resynchronization therapy (CRT) is uncertain.
      Methods: A total of 55 consecutive de novo CRT candidates were enrolled between January 2016 and March 2017. Electrocardiogram (ECG) and TMS were performed before and soon after implantation. The ECG parameters were recorded, including QRS duration and morphology (such as ΔQRS_Index, QTc during biventricular pacing mode [BiV pacing QTc], and QRS/T ratio during biventricular pacing mode [BiV pacing QRS/T ratio]). TMS monitored three sensory vectors of the S-ICD. Six months after implantation, the responses to CRT were evaluated.
      Results: Thirty-nine patients (70.9%) passed the TMS during biventricular pacing mode. At the six-month follow-up, the number of responders and super-responders was significantly higher in the passing group than in the non-passing group (responders: 31/39 [79.5%] vs. 5/16 [31.3%], p<0.001; super-responders: 9/39 [23.1%] vs. 1/16 [6.3%], p=0.020). The super-response rate was higher among patients who passed all three vectors than among those who passed 1 or 2 vectors (3 vs. 2 vectors, p=0.018; 3 vs. 1 vector, p=0.003). A smaller left atrial diameter, vectors that passed TMS during biventricular pacing mode, and larger ΔQRS_Index values were independently associated with good CRT response.
      Conclusions: Our study demonstrated that patients on CRT who pass the TMS during biventricular pacing mode are more likely to respond and super-respond to CRT.

      더보기

      참고문헌 (Reference)

      1 Olde Nordkamp LR, "Which patients are not suitable for a subcutaneous ICD : incidence and predictors of failed QRS-T-wave morphology screening" 25 : 494-499, 2014

      2 Groh CA, "Use of an electrocardiographic screening tool to determine candidacy for a subcutaneous implantable cardioverter-defibrillator" 11 : 1361-1366, 2014

      3 Bacharova L, "The role of ECG in the diagnosis of left ventricular hypertrophy" 10 : 257-261, 2014

      4 Hiraiwa H, "The Selvester QRS score as a predictor of cardiac events in nonischemic dilated cardiomyopathy" 71 : 284-290, 2018

      5 Zeb M, "Sensitivity and specificity of the subcutaneous implantable cardioverter defibrillator pre-implant screening tool" 195 : 205-209, 2015

      6 Burke MC, "Safety and efficacy of the totally subcutaneous implantable defibrillator : 2-year results from a pooled analysis of the IDE study and EFFORTLESS registry" 65 : 1605-1615, 2015

      7 Guo JP, "Role of electrocardiogram in predicting cardiac resynchronization therapy response" 44 : 483-488, 2016

      8 Lang RM, "Recommendations for cardiac chamber quantification by echocardiography in adults : an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging" 16 : 233-270, 2015

      9 Rickard J, "QRS narrowing is associated with reverse remodeling in patients with chronic right ventricular pacing upgraded to cardiac resynchronization therapy" 10 : 55-60, 2013

      10 van Stipdonk AM, "QRS area is a strong determinant of outcome in cardiac resynchronization therapy" 11 : e006497-, 2018

      1 Olde Nordkamp LR, "Which patients are not suitable for a subcutaneous ICD : incidence and predictors of failed QRS-T-wave morphology screening" 25 : 494-499, 2014

      2 Groh CA, "Use of an electrocardiographic screening tool to determine candidacy for a subcutaneous implantable cardioverter-defibrillator" 11 : 1361-1366, 2014

      3 Bacharova L, "The role of ECG in the diagnosis of left ventricular hypertrophy" 10 : 257-261, 2014

      4 Hiraiwa H, "The Selvester QRS score as a predictor of cardiac events in nonischemic dilated cardiomyopathy" 71 : 284-290, 2018

      5 Zeb M, "Sensitivity and specificity of the subcutaneous implantable cardioverter defibrillator pre-implant screening tool" 195 : 205-209, 2015

      6 Burke MC, "Safety and efficacy of the totally subcutaneous implantable defibrillator : 2-year results from a pooled analysis of the IDE study and EFFORTLESS registry" 65 : 1605-1615, 2015

      7 Guo JP, "Role of electrocardiogram in predicting cardiac resynchronization therapy response" 44 : 483-488, 2016

      8 Lang RM, "Recommendations for cardiac chamber quantification by echocardiography in adults : an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging" 16 : 233-270, 2015

      9 Rickard J, "QRS narrowing is associated with reverse remodeling in patients with chronic right ventricular pacing upgraded to cardiac resynchronization therapy" 10 : 55-60, 2013

      10 van Stipdonk AM, "QRS area is a strong determinant of outcome in cardiac resynchronization therapy" 11 : e006497-, 2018

      11 Hsu JC, "Predictors of super-response to cardiac resynchronization therapy and associated improvement in clinical outcome : the MADIT-CRT(multicenter automatic defibrillator implantation trial with cardiac resynchronization therapy)study" 59 : 2366-2373, 2012

      12 Killu AM, "Predictors and outcomes of"super-response"to cardiac resynchronization therapy" 20 : 379-386, 2014

      13 Hadjis A, "Predicting response to cardiac resynchronization therapy : use of strict left bundle branch block criteria" 42 : 431-438, 2019

      14 Brouwer TF, "Long-term clinical outcomes of subcutaneous versus transvenous implantable defibrillator therapy" 68 : 2047-2055, 2016

      15 Kuperstein R, "Left atrial volume and the benefit of cardiac resynchronization therapy in the MADIT-CRT trial" 7 : 154-160, 2014

      16 Burri H, "Iterative method for atrioventricular optimization of cardiac resynchronization therapy: is beauty only in the eye of the beholder?" 16 : 1865-1866, 2014

      17 António N, "Identification of ‘super-responders’ to cardiac resynchronization therapy : the importance of symptom duration and left ventricular geometry" 11 : 343-349, 2009

      18 Randles DA, "How many patients fulfil the surface electrocardiogram criteria for subcutaneous implantable cardioverter-defibrillator implantation?" 16 : 1015-1021, 2014

      19 Cai C, "High sensitivity C-reactive protein and cardfiac resynchronization therapy in patients with advanced heart failure" 11 : 296-302, 2014

      20 Ip JE, "Eligibility of pacemaker patients for subcutaneous implantable cardioverter defibrillators" 28 : 544-548, 2017

      21 Ziacchi M, "Electrocardiographic eligibility for subcutaneous implantable cardioverter defibrillator : evaluation during bicycle exercise" 25 : 476-483, 2016

      22 Chalil S, "Effect of posterolateral left ventricular scar on mortality and morbidity following cardiac resynchronization therapy" 30 : 1201-1209, 2007

      23 Xue C, "Effect of cardiac resynchronization therapy in patients with dispersion of repolarization and ventricular arrhythmia" 31 : 250-253, 2016

      24 Yanagisawa S, "Clinical characteristics and predictors of super-response to cardiac resynchronization therapy : a combination of predictive factors" 37 : 1553-1564, 2014

      25 Kawabata M, "Candidacy for a subcutaneous implantable cardioverter defibrillator in patients with cardiac resynchronization therapy" 59 : 951-958, 2018

      26 Fontaine JM, "Biventricular paced QRS predictors of left ventricular lead locations in relation to mortality in cardiac resynchronization therapy" 48 : 226-235, 2015

      27 Fujinami M, "Association between the baseline peripheral blood monocyte counts, the size of spleen, and the response to cardiac resynchronization therapy" 71 : 299-304, 2018

      28 Corbalan R, "Analysis of outcomes in ischemic vs nonischemic cardiomyopathy in patients with atrial fibrillation : a report from the GARFIELD-AF registry" 4 : 526-548, 2019

      29 Ponikowski P, "2016 ESC guidelines for the diagnosis and treatment of acute and chronic heart failure" 69 : 1167-, 2016

      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2011-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2009-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2008-05-15 학회명변경 한글명 : 대한순환기학회 -> 대한심장학회
      영문명 : The Korean Society Of Circulation -> The Korean Society of Cardiology
      KCI등재
      2007-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2005-08-02 학술지등록 한글명 : Korean Circulation Journal
      외국어명 : Korean Circulation Journal
      KCI등재
      2004-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2003-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2001-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 1.13 0.34 0.71
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.45 0.36 0.52 0.12
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼