1 Errico,T.J, "Why a mechanical disc" 4 (4): 151S-157S, 2004
2 Kurtz,S.M, "What is the correlation of in vivo wear and damage patterns with in vitro TDR motion response" 33 (33): 481-489, 2008
3 Lee,K.Y, "Wear of shelf-aged UHMWPE acetabular liners" 225 (225): 728-733, 1999
4 이권용, "Wear of Retrieved UHMWPE Hip Liners" 연세대학교의과대학 45 (45): 293-299, 2004
5 Saikko,V, "Wear and friction properties of prosthetic joint materials evaluated on a reciprocating pin-on-flat apparatus" 166 (166): 169-178, 1993
6 Harris,W.H, "The problem is osteolysis" 311 : 46-53, 1995
7 Goldring,S.R, "The problem in total joint arthroplasty:Aseptic loosening" 75 (75): 799-801, 1993
8 Yao,J.Q, "The influences of lubricant and material on polymer/CoCr sliding friction" 255 (255): 780-784, 2003
9 Bragdon,C.R, "The importance of multidirectional motion on the wear of polyethylene" 210 (210): 157-165, 1996
10 Harper,M.L, "The fundamentals of biotribology and its application to spine arthroplasty" 3 (3): 125-132, 2009
1 Errico,T.J, "Why a mechanical disc" 4 (4): 151S-157S, 2004
2 Kurtz,S.M, "What is the correlation of in vivo wear and damage patterns with in vitro TDR motion response" 33 (33): 481-489, 2008
3 Lee,K.Y, "Wear of shelf-aged UHMWPE acetabular liners" 225 (225): 728-733, 1999
4 이권용, "Wear of Retrieved UHMWPE Hip Liners" 연세대학교의과대학 45 (45): 293-299, 2004
5 Saikko,V, "Wear and friction properties of prosthetic joint materials evaluated on a reciprocating pin-on-flat apparatus" 166 (166): 169-178, 1993
6 Harris,W.H, "The problem is osteolysis" 311 : 46-53, 1995
7 Goldring,S.R, "The problem in total joint arthroplasty:Aseptic loosening" 75 (75): 799-801, 1993
8 Yao,J.Q, "The influences of lubricant and material on polymer/CoCr sliding friction" 255 (255): 780-784, 2003
9 Bragdon,C.R, "The importance of multidirectional motion on the wear of polyethylene" 210 (210): 157-165, 1996
10 Harper,M.L, "The fundamentals of biotribology and its application to spine arthroplasty" 3 (3): 125-132, 2009
11 Cornwall,G.B, "The effect of kinematic conditions on the wear of ultra-high molecular weight polyethylene(UHMWPE)in orthopaedic bearing applications" 215 (215): 95-106, 2001
12 Kurtz, S. M, "The UHMWPE handbook: ultra-high molecular weight polyethylene in total joint replacement, 2nd Edition" Academic Press 2004
13 Sutula,L.C, "The Otto Aufranc Award:Impact of gamma sterilization on clinical performance of polyethylene in the hip" 319 : 28-40, 1995
14 O’Beirne,J, "Spinal fusion for back pain:a clinical and radiological review" 5 (5): 32-38, 1992
15 Kurtz,S.M, "Retrieval analysis of motion preserving spinal devices and periprosthetic tissues" 3 (3): 161-177, 2009
16 West,J.L, "Results of spinal arthrodesis with pedicle screw-plate fixation" 73 (73): 1179-1184, 1991
17 Cinotti,G, "Results of disc prosthesis after a minimum follow-up period of 2 years" 21 (21): 995-1000, 1996
18 Turell,M, "Quantification of the effect of cross-path motion on the wear rate of ultra-high molecular weight polyethylene" 255 (255): 1034-1039, 2003
19 Kafer,W, "Posterior component impingement after lumbar total disc replacement:a radiographic analysis of 66 ProDisc-L prostheses in 56 patients" 33 (33): 2444-2449, 2008
20 Kurtz,S.M, "Polyethylene wear and rim fracture in total disc arthroplasty" 7 (7): 12-21, 2007
21 Gupta,S.K, "Osteolysis after total knee arthroplasty" 22 (22): 787-799, 2007
22 Billi,F, "Metal wear particles:What we know,what we do not know,and why" 3 (3): 133-142, 2009
23 Amstutz,H.C, "Mechanism and clinical significance of wear debris-induced osteolysis" 276 : 7-18, 1992
24 Chen, W. M, "Lumbar spinal adaptations in response to disc arthroplasty with total disc replacement: A finite element model analysis" Inje University 2007
25 Shaheen,A, "Lubrication regimes in lumbar total disc arthroplasty" 221 (221): 621-627, 2007
26 Huang,R.C, "Long-term flexion-extension range of motion of the prodisc total disc replacement" 16 (16): 435-440, 2003
27 Serhan,H.A, "In vitro wear assessment of the Charité artificial disc according to ASTM recommendations" 31 (31): 1900-1910, 2006
28 Chen,W.M, "In situ contact analysis of the prosthesis components of Prodisc-L in lumbar spine following total disc replacement" 34 (34): E716-E723, 2009
29 Bono,C.M, "History and evolution of disc replacement" 4 (4): 145S-150S, 2004
30 Premnath,V, "Gamma sterilization of UHMWPE articular implants:an analysis of the oxidation problem" 17 (17): 1741-1753, 1996
31 Gispert,M.P, "Friction and wear mechanisms in hip prosthesis:Comparison of joint materials behavior in several lubricants" 260 (260): 149-158, 2006
32 Tetreault,D.M, "Friction and wear behavior of ultrahigh molecular weight polyethylene on Co-Cr AND Titanium alloys in dry and lubricated environments" 133 (133): 295-307, 1989
33 Moumene,M, "Comparison of biomechanical function at ideal and varied surgical placement for two lumbar artificial disc implant designs:mobile-core versus fixed-core" 32 (32): 1840-1851, 2007
34 Fritzell,P, "Chronic low back pain and fusion:a comparison of three surgical techniques:a prospective multicenter randomized study from the Swedish Lumbar spine study group" 27 (27): 1131-1141, 2002
35 Kurtz,S.M, "Analysis of retrieved polyethylene total disc replacement component" 5 (5): 344-350, 2005
36 Lee,C.K, "Accelerated degeneration of the segment adjacent to a lumbar fusion" 13 (13): 375-377, 1998