This study has been carried out to evaluate the effect on desulfurization of flue gas by Mg(OH)₂in steam-power cogeneration plant. We investigated the effects of desulfurizatin on the temperature of flue gas and pH of circulation water in aborber. T...
This study has been carried out to evaluate the effect on desulfurization of flue gas by Mg(OH)₂in steam-power cogeneration plant. We investigated the effects of desulfurizatin on the temperature of flue gas and pH of circulation water in aborber. The desulfurization installations of flue gas in cogeneration and thermoelectric power plant will be increased every year because of stricted environmental regulation in Korea.
Some conclusions obtained are summerized as follows ;
1. With regard to running cost, Mg(OH)₂ absorbent for desulfurization of flue gas snowed more economic than Ca(OH)₂.
2. While bunker-C oil with 1.6% sulfur was used, desulfurization of flue gas by Mg(OH)₂ was performed and then SO₂ content in the exhausted gas was under 50 ppm.