      Magnitude of beam-hardening artifacts produced by gutta-percha and metal posts on conebeam computed tomography with varying tube current

      한글로보기

      https://www.riss.kr/link?id=A106639428

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Purpose: This study was performed to evaluate the magnitude of artifacts produced by gutta-percha and metal posts on cone-beam computed tomography (CBCT) scans obtained with different tube currents and with or without metal artifact reduction (MAR). ...

      Purpose: This study was performed to evaluate the magnitude of artifacts produced by gutta-percha and metal posts on cone-beam computed tomography (CBCT) scans obtained with different tube currents and with or without metal artifact reduction (MAR).
      Materials and Methods: A tooth was inserted in a dry human mandible socket, and CBCT scans were acquired after root canal instrumentation, root canal filling, and metal post placement with various tube currents with and without MAR activation. The artifact magnitude was assessed by the standard deviation (SD) of gray values and the contrastto- noise ratio (CNR) at the various distances from the tooth. Data were compared using multi-way analysis of variance.
      Results: At all distances, a current of 4 mA was associated with a higher SD and a lower CNR than 8 mA or 10 mA (P<0.05). For the metal posts without MAR, the artifact magnitude as assessed by SD was greatest at 1.5 cm or less (P<0.05). When MAR was applied, SD values for distances 1.5 cm or closer to the tooth were reduced (P<0.05).
      MAR usage did not influence the magnitude of artifacts in the control and gutta-percha groups (P>0.05).
      Conclusion: Increasing the tube current from 4 mA to 8 mA may reduce the magnitude of artifacts from metal posts. The magnitude of artifacts arising from metal posts was significantly higher at distances of 1.5 cm or less than at greater distances. MAR usage improved image quality near the metal post, but had no significant influence farther than 1.5 cm from the tooth.

      더보기

      참고문헌 (Reference)

      1 Vasconcelos KF, "The performance of metal artifact reduction algorithms in cone beam computed tomography images considering the effects of materials, metal positions, and fields of view" 127 : 71-76, 2019

      2 Cebe F, "The effects of different restorative materials on the detection of approximal caries in cone-beam computed tomography scans with and without metal artifact reduction mode" 123 : 392-400, 2017

      3 Pauwels R, "Quantification of metal artifacts on cone beam computed tomography images" 24 (24): 94-99, 2013

      4 Pauwels R, "Optimization of dental CBCT exposures through mAs reduction" 44 : 20150108-, 2015

      5 Candemil AP, "Metallic materials in the exomass impair cone beam CT voxel values" 47 : 20180011-, 2018

      6 Fontenele RC, "Magnitude of cone beam CT image artifacts related to zirconium and titanium implants : impact on image quality" 47 : 20180021-, 2018

      7 Freitas DQ, "Influence of acquisition parameters on the magnitude of cone beam computed tomography artifacts" 47 : 20180151-, 2018

      8 Sancho-Puchades M, "In vitro assessment of artifacts induced by titanium, titanium-zirconium and zirconium dioxide implants in cone-beam computed tomography" 26 : 1222-1228, 2015

      9 Queiroz PM, "Evaluation of metal artefact reduction in cone-beam computed tomography images of different dental materials" 22 : 419-423, 2018

      10 Neves FS, "Evaluation of cone-beam computed tomography in the diagnosis of vertical root fractures : the influence of imaging modes and root canal materials" 40 : 1530-1536, 2014

      1 Vasconcelos KF, "The performance of metal artifact reduction algorithms in cone beam computed tomography images considering the effects of materials, metal positions, and fields of view" 127 : 71-76, 2019

      2 Cebe F, "The effects of different restorative materials on the detection of approximal caries in cone-beam computed tomography scans with and without metal artifact reduction mode" 123 : 392-400, 2017

      3 Pauwels R, "Quantification of metal artifacts on cone beam computed tomography images" 24 (24): 94-99, 2013

      4 Pauwels R, "Optimization of dental CBCT exposures through mAs reduction" 44 : 20150108-, 2015

      5 Candemil AP, "Metallic materials in the exomass impair cone beam CT voxel values" 47 : 20180011-, 2018

      6 Fontenele RC, "Magnitude of cone beam CT image artifacts related to zirconium and titanium implants : impact on image quality" 47 : 20180021-, 2018

      7 Freitas DQ, "Influence of acquisition parameters on the magnitude of cone beam computed tomography artifacts" 47 : 20180151-, 2018

      8 Sancho-Puchades M, "In vitro assessment of artifacts induced by titanium, titanium-zirconium and zirconium dioxide implants in cone-beam computed tomography" 26 : 1222-1228, 2015

      9 Queiroz PM, "Evaluation of metal artefact reduction in cone-beam computed tomography images of different dental materials" 22 : 419-423, 2018

      10 Neves FS, "Evaluation of cone-beam computed tomography in the diagnosis of vertical root fractures : the influence of imaging modes and root canal materials" 40 : 1530-1536, 2014

      11 Bechara B, "Evaluation of a cone beam CT artefact reduction algorithm" 41 : 422-428, 2012

      12 de-Azevedo-Vaz SL, "Efficacy of a cone beam computed tomography metal artifact reduction algorithm for the detection of peri-implant fenestrations and dehiscences" 121 : 550-556, 2016

      13 Ava Nikbin, "Effect of object position in the field of view and application of a metal artifact reduction algorithm on the detection of vertical root fractures on cone-beam computed tomography scans: An in vitro study" 대한영상치의학회 48 (48): 245-254, 2018

      14 Nascimento EH, "Difference in the artefacts production and the performance of the metal artefact reduction(MAR)tool between the buccal and lingual cortical plates adjacent to zirconium dental implant" 48 : 20190058-, 2019

      15 Freitas DQ, "Diagnosis of vertical root fracture in teeth close and distant to implant : an in vitro study to assess the influence of artifacts produced in cone beam computed tomography" 23 : 1263-1270, 2019

      16 Freitas DQ, "Diagnosis of external root resorption in teeth close and distant to zirconium implants : influence of acquisition parameters and artefacts produced during cone beam computed tomography" 52 : 866-873, 2019

      17 Prashant P. Jaju, "Cone-beam computed tomography: Time to move from ALARA to ALADA" 대한영상치의학회 45 (45): 263-265, 2015

      18 Parsa A, "Assessment of metal artefact reduction around dental titanium implants in cone beam CT" 43 : 20140019-, 2014

      19 Kamburoǧlu K, "Assessment of furcal perforations in the vicinity of different root canal sealers using a cone beam computed tomography system with and without the application of artifact reduction mode : an ex vivo investigation on extracted human teeth" 121 : 657-665, 2016

      20 Lira de Farias Freitas AP, "Assessment of artefacts produced by metal posts on CBCT images" 52 : 223-236, 2018

      21 Schulze R, "Artefacts in CBCT : a review" 40 : 265-273, 2011

      22 Pauwels R, "A pragmatic approach to determine the optimal kVp in cone beam CT : balancing contrast-to-noise ratio and radiation dose" 43 : 20140059-, 2014

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2019-03-27 학회명변경 한글명 : 대한구강악안면방사선학회 -> 대한영상치의학회 KCI등재
      2012-04-16 학술지명변경 한글명 : 대한구강악안면방사선학회지 -> Imaging Science in Dentistry KCI등재
      2011-03-29 학술지명변경 외국어명 : Korean Journal of Oral and Maxillofacial Radiology -> Imaging Science in Dentistry KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2008-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2006-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2003-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2002-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2000-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.12 0.12 0.11
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.11 0.12 0.217 0.02
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼