      변압기 온라인 진단을 위한 절연유 광투과율 연구 = Study on Transformer Online Discrimination Using Light Transmittance of Insulating Oil

      한글로보기

      https://www.riss.kr/link?id=A109353560

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

      The purpose of this study is the fault discrimination of the transformer that supplies power in demand. In this study, the correlation between the light transmittance of the insulating oil and dielectric breakdown was used to the fault discrimination of the transformer.
      In this study, the light sources of various wavelengths were compared, and it was shown in the paper that the selected 520 nm light sources can clearly diagnose the deterioration state. In addition, in order to evaluate the total dielectric breakdown of the insulating oil, research was conducted through various samples through the collection of insulating oil samples and acceleration deterioration tests of the used transformer. It is believed that the diagnostic method for the state of the transformer using the light transmittance of the insulating oil proposed through this study can help secure the reliability and economy of the power facility.
      번역하기

      The purpose of this study is the fault discrimination of the transformer that supplies power in demand. In this study, the correlation between the light transmittance of the insulating oil and dielectric breakdown was used to the fault discrimination ...

      The purpose of this study is the fault discrimination of the transformer that supplies power in demand. In this study, the correlation between the light transmittance of the insulating oil and dielectric breakdown was used to the fault discrimination of the transformer.
      In this study, the light sources of various wavelengths were compared, and it was shown in the paper that the selected 520 nm light sources can clearly diagnose the deterioration state. In addition, in order to evaluate the total dielectric breakdown of the insulating oil, research was conducted through various samples through the collection of insulating oil samples and acceleration deterioration tests of the used transformer. It is believed that the diagnostic method for the state of the transformer using the light transmittance of the insulating oil proposed through this study can help secure the reliability and economy of the power facility.

      더보기

      참고문헌 (Reference)

      1 Al Hafez, "Treatment of aged transformer oil using dry sludge in lab-scale refining unit" 2 (2): 010-022, 2015

      2 Michel Duval, "The Duval Triangle for Load Tap Changers, Non-Mineral Oils and Low Temperature Faults in Transformer" 24 (24): 22-29, 2008

      3 Haksun Im, "Study on Optimizing Transformer Replacement Cycle" 2019

      4 Hyun-joo Park, "Proposals for an Optimum Analysis Method for Furanic Compound in Insulating Oil for Paper Degradation Assessment" 2009

      5 Michel Duval, "Interpretation of Gas-In-Oil Analysis Using New IEC Publication 60599and IEC TC 10 Database" 17 (17): 31-41, 2001

      6 Irungu, G. K., "Fault diagnostics in oil filled electrical equipment: Review of duval triangle and possibility of alternatives" 2016

      7 김춘동 ; 김철규 ; 박세현, "Development of Portable Dissolved Gas Analyzer Using photoacoustic spectroscopy" 17 (17): 2431-2438, 2013

      8 Seungpil Moon, "Basic study on the method of utilizing the transmittance of insulation oil for diagnosing a transformer" 350-351, 2020

      9 Hyeong-Gu Kang, "A transformer lifetime prediction and failure diagnosis algorithm using probability theories" 2022

      10 ISLAM Md Mominul, "A review of condition monitoring techniques and diagnostic tests for lifetime estimation of power transformers" 100 : 581-605, 2018

      1 Al Hafez, "Treatment of aged transformer oil using dry sludge in lab-scale refining unit" 2 (2): 010-022, 2015

      2 Michel Duval, "The Duval Triangle for Load Tap Changers, Non-Mineral Oils and Low Temperature Faults in Transformer" 24 (24): 22-29, 2008

      3 Haksun Im, "Study on Optimizing Transformer Replacement Cycle" 2019

      4 Hyun-joo Park, "Proposals for an Optimum Analysis Method for Furanic Compound in Insulating Oil for Paper Degradation Assessment" 2009

      5 Michel Duval, "Interpretation of Gas-In-Oil Analysis Using New IEC Publication 60599and IEC TC 10 Database" 17 (17): 31-41, 2001

      6 Irungu, G. K., "Fault diagnostics in oil filled electrical equipment: Review of duval triangle and possibility of alternatives" 2016

      7 김춘동 ; 김철규 ; 박세현, "Development of Portable Dissolved Gas Analyzer Using photoacoustic spectroscopy" 17 (17): 2431-2438, 2013

      8 Seungpil Moon, "Basic study on the method of utilizing the transmittance of insulation oil for diagnosing a transformer" 350-351, 2020

      9 Hyeong-Gu Kang, "A transformer lifetime prediction and failure diagnosis algorithm using probability theories" 2022

      10 ISLAM Md Mominul, "A review of condition monitoring techniques and diagnostic tests for lifetime estimation of power transformers" 100 : 581-605, 2018

      11 Sangmin Ryu, "A Basic Study on the Status Diagnosis of Transformer Using Physical Properties of Insulating oil" 1720-1721, 2020

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼