RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCI SCIE SCOPUS

      Microwire Magneto-Resonance Characteristics in a Magnetic LC-Resonator Device

      한글로보기

      https://www.riss.kr/link?id=A104321575

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      In the present work, the magneto-resonance characteristics in a LC-resonator device built on amorphous glass-coated Co-based ferromagnetic microwires have been investigated. The giant magnetoimpedance (GMI) measurements were conducted in the high-freq...

      In the present work, the magneto-resonance characteristics in a LC-resonator device built on amorphous glass-coated Co-based ferromagnetic microwires have been investigated. The giant magnetoimpedance (GMI) measurements were conducted in the high-frequency range of 100 { 800 MHz and for a dc magnetic field varying within 120 Oe. The variation in the diameter of the microwire had significant effects on the magnitude of the GMI effect, the characteristic resonance frequencies and the positions of the resonant peaks. The resonance in a LC-resonator device occurs at a specific intensity of the applied dc magnetic field. Noticeably, the largest field sensitivity of the GMI reaches extremely high values of 20,000 %/Oe and 18,000 %/Oe at resonance frequencies of 518.21 MHz and 146.25 MHz for LC-resonators constructed using Co83.2B3.3Si5.9Mn7.6 and Co67Fe3.8Ni1.4B11.5Si14.6Mo1.7 microwires, respectively. These results are of great interest for developing a new class of ultra-sensitives, high-frequency GMI-based magnetic sensors.

      더보기

      참고문헌 (Reference)

      1 V. Raposo, 106 : 329-, 2003

      2 L. V. Panina, 65 : 1189-, 1994

      3 L. Kraus, 106 : 187-, 2003

      4 K. Mandai, 65 : 64402-, 2002

      5 L. A. Than, 40 : 4582-, 2007

      6 Y. S. Kim, 304 : e365-, 2006

      7 M. Knobel, 242-245 : 33-, 2002

      8 M. Vazquez, 226-230 : 693-, 2001

      9 Heebok Lee, "Super-giant Magneto-Impedance Effect of a LC-resonator Using a Glass-Coated Amorphous Microwire" 한국자기학회 7 (7): 160-164, 2002

      10 P. Ripka, "Magnetic Sensors and Magnetometers" Artech House Publishers 2001

      1 V. Raposo, 106 : 329-, 2003

      2 L. V. Panina, 65 : 1189-, 1994

      3 L. Kraus, 106 : 187-, 2003

      4 K. Mandai, 65 : 64402-, 2002

      5 L. A. Than, 40 : 4582-, 2007

      6 Y. S. Kim, 304 : e365-, 2006

      7 M. Knobel, 242-245 : 33-, 2002

      8 M. Vazquez, 226-230 : 693-, 2001

      9 Heebok Lee, "Super-giant Magneto-Impedance Effect of a LC-resonator Using a Glass-Coated Amorphous Microwire" 한국자기학회 7 (7): 160-164, 2002

      10 P. Ripka, "Magnetic Sensors and Magnetometers" Artech House Publishers 2001

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2011-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2009-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2007-01-01 평가 SCI 등재 (등재유지) KCI등재
      2005-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2002-07-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2000-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.47 0.15 0.31
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.26 0.2 0.26 0.03
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼