      CAD/CAM system으로 제작한 zirconia core의 적합도 = THE FIT OF ZIRCONIA FORE FABRICATED WITH CAD/CAM SYSTEM

      한글로보기

      https://www.riss.kr/link?id=A100748451

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Statement of problem: The use of zirconia prostheses fabricated with CAD/CAM system is on an increasing trend in dentistry. However, evaluation of the fit related to internal relief and marginal reproducibility of zirconia has not been reported. Purpo...

      Statement of problem: The use of zirconia prostheses fabricated with CAD/CAM system is on an increasing trend in dentistry. However, evaluation of the fit related to internal relief and marginal reproducibility of zirconia has not been reported. Purpose : This study was to evaluate the fit related to internal relief and marginal reproducibility of zirconia core fabricated with CAD/CAM system. Materials and methods: The evaluation was based on 30 zirconia cores and 5 IPS-Empress2 cores. Zirconia cores were fabricated in different conditions of internal relief(0, 10, 20, 30, 40 and $50{\mu}m$), and IPS-Empress2 cores were fabricated in accordance with the manufacturer's instructions. Before cementation, the marginal discrepancies or cores were measured on metal die. And then, each core was cemented to stone die, embedded in an acrylic resin and sectioned in two planes(mesiodistally and labiopalatally). The internal gaps were measured at the margin and axial surface. Measurements for the marginal discrepancies, the internal marginal gaps and the internal axial gaps were performed under a measuring microscope(Compact measuring microscope STM5; Olympus, Japan) at a magnification of ${\times}100$. In addition, the marginal conagurations of metal die, zirconia core and IPS-Empress2 core were examined with SEM(S-2700, Hitachi, Japan). Results : Within the limits of this study the results were as follows. 1. Compared with IPS-Empress2 cores, the marginal discrepancies of zirconia cores had no significant differences. the internal marginal gaps were statistically smaller and the internal axial gaps were statistically larger in each condition of internal relief. 2. The marginal discrepancies and the internal marginal gaps of zirconia cores had no significant differences related to the conditions of internal relief(P>0.05). 3. The internal axial gaps of zirconia cores with $0{\sim}20{\mu}$m for internal relief were significantly larger than that with $50{\mu}m$ (P<(0.0001). 4. SEM micrographs showed favorable marginal reproducibility of zirconia core and smooth texture on the milling surface. Conclusion: The marginal discrepancy and the internal gaps of zirconia core were clinically acceptable and the milling surface was showed smooth texture. For fabrication of the durable esthetic restoration, further investigations on complex design of core, milling accuracy, compatability of enamel porcelain and porcelain firing seems to be needed.

      더보기

      참고문헌 (Reference)

      1 "The relationshipbetween the film thickness ofzinc phosphate cement and the retentionof veneer crowns" 26 : 169-75, 1968

      2 "The estimationof cement film thickness by an invivo technique" 131 : 107-11, 1971

      3 "The effect ofcement thickness on the fracture strengthof all-ceramic crowns" 40 : 17-21, 1995

      4 "The effect of multiple layers ofdie-spacer on crown retention" 17 : 42-9, Dent1992

      5 "The Three-dimensionaleffects of adjustment and cementation oncrown seating" 6 : 248-54, 1993

      6 "Techniques to improvethe seating of castings" 96 : 432-7, 1978

      7 "Revised american national standards institute/American dental association specificationNo" 96 : 121-3, 1978

      8 "Relief of resistanceof cement of full cast crowns" 14 : 95-106, 1964

      9 "Relative flexuralstrength of six new ceramic materials" 8 : 239-46, 1995

      10 "Product review: All-ceramic system" 46 : 446-50, 1998

      1 "The relationshipbetween the film thickness ofzinc phosphate cement and the retentionof veneer crowns" 26 : 169-75, 1968

      2 "The estimationof cement film thickness by an invivo technique" 131 : 107-11, 1971

      3 "The effect ofcement thickness on the fracture strengthof all-ceramic crowns" 40 : 17-21, 1995

      4 "The effect of multiple layers ofdie-spacer on crown retention" 17 : 42-9, Dent1992

      5 "The Three-dimensionaleffects of adjustment and cementation oncrown seating" 6 : 248-54, 1993

      6 "Techniques to improvethe seating of castings" 96 : 432-7, 1978

      7 "Revised american national standards institute/American dental association specificationNo" 96 : 121-3, 1978

      8 "Relief of resistanceof cement of full cast crowns" 14 : 95-106, 1964

      9 "Relative flexuralstrength of six new ceramic materials" 8 : 239-46, 1995

      10 "Product review: All-ceramic system" 46 : 446-50, 1998

      11 "Precision of fit: The Procera Allceramcrown" 80 : 394-404, 1998

      12 "On Themarginal fidelity of all-ceramic core usingCAD/CAM system" 41 : 20-34, 2003

      13 "Marginalfit of alumina- and zirconia-basedfixed partial dentures produced by a CAD/CAM system" 26 : 367-74, 2001

      14 "Marginal of completecrowns-Literature review" 48 : 396-400, Dent1982

      15 "Marginal fit of porcelain-fused-to-metal andtwo types of ceramic crown" 63 : 26-31, Dent1990

      16 "Marginal fit of Celay/In-ceram,conventionalIn-ceram and Empress 2 All-ceramic singlecrowns" 40 : 131-139, 2002

      17 "Marginal adaptation ofthe conical inner crown fabrication withCAD/CAM" 40 : 30-41, 2002

      18 "Marginal adaptation of titanium frameworksproduced by CAD/CAM techniques" 10 : 541-6, 1997

      19 "Marginal Fit of GoldCastings" 16 : 297-305, 1966

      20 "Margin gap size of ceramic in-lays usingsecond-generation CAD/CAM equipment" 11 : 206-14, 1999

      21 "Improving the fit of crowns with die spacers" 61 : 555-63, 1989

      22 "High-technology innovationsandlimitations for restorative dentistry" 37 : 513-24, 1993

      23 "Grinding precisionand accuracy of fit of CEREC2 CAD-CIMinlays" 128 : 47-53, 1997

      24 "Factors affecting the filmthickness of zinc phosphate cement" 18 : 479-90, 1960

      25 "Effects of cement and seatingforce on crown cementation" 786-90, jprosthetdent1992

      26 "Design and fabrication of inner konuscrown using three dimensional computergraphics" 38 : 544-51, 2000

      27 "Considerations in measurement of marginalfit" 62 : 405-8, 1989

      28 "Clinical fit ofProcera Allceram crowns" 84 : 419-24, 2000

      29 "An experimental studyon the fitness of the cervical margin in theceramo-metal crown according to the alloytypes and the curvature of labio-cervicalmargin" 29 : 181-196, 1991

      30 "An experimental study on thecervial margin fitness in the collarlessmetal ceramic crowns formed by differenttechniques" 28 : 203-212, 1990

      31 "Accuracy of machine millingand spark erosion with a CAD/CAM system" 76 : 187-93, 1996

      32 "A study on themarginal fidelities and fracture strength ofIPS EMPRESS 2 ceramic crowns" 38 : 606-616, 2000

      33 "A study on the physicalcharacteristics of the three commonlyused die spacing materials" 37 : 640-650, 1999

      34 "A study on the marginal fit of all-ceramiccrowns using CCD camera" 36 : 273-292, 1998

      35 "A comparisonof the marginal and internaladaptation of titanium and gold-platinum-palladium metal ceramic crowns" 8 : 29-37, 1995

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2026 평가예정 재인증평가 신청대상 (재인증)
      2020-01-01 평가 등재학술지 유지 (재인증) KCI등재
      2017-01-01 평가 등재학술지 유지 (계속평가) KCI등재
      2013-01-01 평가 등재 1차 FAIL (등재유지) KCI등재
      2010-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2009-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2009-01-01 평가 학술지 분리 (기타) KCI등재후보
      2007-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2004-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2003-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2001-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.22 0.22 0.2
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.21 0.21 0.353 0
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼