RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      SCOPUS KCI등재

      고성능 액체 크로마토그래피의 간접 분광광도법에 의한 THM과 PCB의 분석 = Analysis of THMs and PCBs by Indirect Photometric Method in High Performance Liquid Chromatography

      한글로보기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      THMs and PCBs were separated and analysed with elution on Novapak ODS or $\mu-Bondapak$ phenyl column by an eluent containing p-nitrophenol (p-NP). THMs studied were CHCl3, CHBrCl2, CHBr2Cl, and CHBr3, and PCBs used were Aroclor 1221, 1242, 1248, $\alpha-$ and $\beta-BHC.$ It was thought that the retention on the stationary phase and sensitivities of the samples are related to the interaction between the sample and stationary phase or p-NP. THMs were separated completely on the ODS column by elution with MeOH-water (30 : 70) containing $1.0{\times}10^{-4}$ M p-NP and some of PCBs were separated on the phenyl column by elution with $CH_3CN$-water(50 : 50) containing $1.0{\times}10^{-4}$ M p-NP. Detection limits of THMs were from $1.0{\times}10^{-4}$ g to $1.0{\times}10^{-6}$ g. Aroclors were $2{\times}10^{-6}$ g, and $\alpha-$ and $\beta-BHC$ were $2{\times}10^{-4}$ g and $1.0{\times}10^{-4}$ g respectively.
      번역하기

      THMs and PCBs were separated and analysed with elution on Novapak ODS or $\mu-Bondapak$ phenyl column by an eluent containing p-nitrophenol (p-NP). THMs studied were CHCl3, CHBrCl2, CHBr2Cl, and CHBr3, and PCBs used were Aroclor 1221, 1242, 1248, $\al...

      THMs and PCBs were separated and analysed with elution on Novapak ODS or $\mu-Bondapak$ phenyl column by an eluent containing p-nitrophenol (p-NP). THMs studied were CHCl3, CHBrCl2, CHBr2Cl, and CHBr3, and PCBs used were Aroclor 1221, 1242, 1248, $\alpha-$ and $\beta-BHC.$ It was thought that the retention on the stationary phase and sensitivities of the samples are related to the interaction between the sample and stationary phase or p-NP. THMs were separated completely on the ODS column by elution with MeOH-water (30 : 70) containing $1.0{\times}10^{-4}$ M p-NP and some of PCBs were separated on the phenyl column by elution with $CH_3CN$-water(50 : 50) containing $1.0{\times}10^{-4}$ M p-NP. Detection limits of THMs were from $1.0{\times}10^{-4}$ g to $1.0{\times}10^{-6}$ g. Aroclors were $2{\times}10^{-6}$ g, and $\alpha-$ and $\beta-BHC$ were $2{\times}10^{-4}$ g and $1.0{\times}10^{-4}$ g respectively.

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼