      Evaluation of CT Imaging Characteristics and Effect of CTDI Phantom Size on Contrast Materials

      한글로보기

      https://www.riss.kr/link?id=A107198692

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Recently, there have been several physics and clinical studies on the use of lower tube potentials in CT imaging, with the purpose of improving image quality or further reducing radiation dose. We investigated an experimental study using a series of d...

      Recently, there have been several physics and clinical studies on the use of lower tube potentials in CT imaging, with the purpose of improving image quality or further reducing radiation dose. We investigated an experimental study using a series of different sized, polymethyl methacrylate (PMMA) phantoms, demonstrating the potential strategy for dose reduction and to distinguish component of plaque by imaging their energy responses using CT. We investigated the relationship between different sizes of cylinderic PMMA equivalent phantoms with diameter of 12, 16, 20, 24, and 32 cm and used contrast at various tube voltages (80, 100, 120, and 140 kVp) using a 16–detector row CT scanner. The contrast represented CT numbers as different materials for the water, calcium chloride, and iodine. Phantom insertions also allow quantitative measures of image noise, contrast, contrast-to-noise ratio (CNR) and figure of merit (FOM). When evaluating FOM, it was found that the lower kVp provided the better CNR. An experimental study was performed to demonstrate reduced dose for both dose efficient and practical feasibility for different patient sizes and diagnostic tasks by relating achievable CNR and the volume CT dose index (CTDI vol). The use of spectra optimized to the specific application could provide further improvements of distinguishing iodine, calcium and plaque component for patient size. The purpose of this study was to evaluate variations in image noise and contrast using different tube potentials in a CTDI phantom on contrast imaging.

      더보기

      목차 (Table of Contents)

      • 1. Introduction
      • 2. Materials and Methods
      • 3. Results
      • 4. Discussion
      • 5. Conclusion
      • 1. Introduction
      • 2. Materials and Methods
      • 3. Results
      • 4. Discussion
      • 5. Conclusion
      • References
      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼