In a circulating fluidized bed (7.8 ㎝-ID × 250 ㎝-high), flow regimes of coal-air system at room temperature and coal combustion efficiency and temperature profiles along the bed height have been determined. An anthracite domestic coal having hea...
http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
https://www.riss.kr/link?id=A3089409
1984
-
500
SCOPUS,KCI등재,ESCI
학술저널
253-258(6쪽)
0
상세조회0
다운로드다국어 초록 (Multilingual Abstract)
In a circulating fluidized bed (7.8 ㎝-ID × 250 ㎝-high), flow regimes of coal-air system at room temperature and coal combustion efficiency and temperature profiles along the bed height have been determined. An anthracite domestic coal having hea...
In a circulating fluidized bed (7.8 ㎝-ID × 250 ㎝-high), flow regimes of coal-air system at room temperature and coal combustion efficiency and temperature profiles along the bed height have been determined. An anthracite domestic coal having heating value of 4,870 ㎉/ ㎏ was employed. Coal particle sizes were varied 0.205, 0.395 and 0.71 ㎜ for flow regime and 0.71 ㎜ for coal combustion studies. The transition velocity between bubbling and turbulent beds and the transport velocity between turbulent and fast beds have been determined. In a circulating fluidized bed, combustion efficiency was higher in the turbulent bed than that in the bubbling bed. Steady combustion operation can be easily maintained at much lower temperature in the turbulent bed than in the bubbling bed.