RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      SCI SCIE SCOPUS

      Semiautomated spleen volumetry with diffusion‐weighted MR imaging

      한글로보기

      https://www.riss.kr/link?id=A107653848

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      <P><B>Abstract</B></P><P>In this article, we determined the relative accuracy of semiautomated spleen volumetry with diffusion‐weighted (DW) MR images compared to standard manual volumetry with DW‐MR or CT images. Semiautomated spleen volumetry using simple thresholding followed by 3D and 2D connected component analysis was performed with DW‐MR images. Manual spleen volumetry was performed on DW‐MR and CT images. In this study, 35 potential live liver donor candidates were included. Semiautomated volumetry results were highly correlated with manual volumetry results using DW‐MR (<I>r</I> = 0.99; <I>P</I> < 0.0001; mean percentage absolute difference, 1.43 ± 0.94) and CT (<I>r</I> = 0.99; <I>P</I> < 0.0001; 1.76 ± 1.07). Mean total processing time for semiautomated volumetry was significantly shorter compared to that of manual volumetry with DW‐MR (<I>P</I> < 0.0001) and CT (<I>P</I> < 0.0001). In conclusion, semiautomated spleen volumetry with DW‐MR images can be performed rapidly and accurately when compared with standard manual volumetry. Magn Reson Med, 2012. © 2011 Wiley Periodicals, Inc.</P>
      번역하기

      <P><B>Abstract</B></P><P>In this article, we determined the relative accuracy of semiautomated spleen volumetry with diffusion‐weighted (DW) MR images compared to standard manual volumetry with DW‐MR or CT ima...

      <P><B>Abstract</B></P><P>In this article, we determined the relative accuracy of semiautomated spleen volumetry with diffusion‐weighted (DW) MR images compared to standard manual volumetry with DW‐MR or CT images. Semiautomated spleen volumetry using simple thresholding followed by 3D and 2D connected component analysis was performed with DW‐MR images. Manual spleen volumetry was performed on DW‐MR and CT images. In this study, 35 potential live liver donor candidates were included. Semiautomated volumetry results were highly correlated with manual volumetry results using DW‐MR (<I>r</I> = 0.99; <I>P</I> < 0.0001; mean percentage absolute difference, 1.43 ± 0.94) and CT (<I>r</I> = 0.99; <I>P</I> < 0.0001; 1.76 ± 1.07). Mean total processing time for semiautomated volumetry was significantly shorter compared to that of manual volumetry with DW‐MR (<I>P</I> < 0.0001) and CT (<I>P</I> < 0.0001). In conclusion, semiautomated spleen volumetry with DW‐MR images can be performed rapidly and accurately when compared with standard manual volumetry. Magn Reson Med, 2012. © 2011 Wiley Periodicals, Inc.</P>

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼