      내시경적 갑상선 수술 중 발견된 armored tube 폐쇄와 기도 열상 = Airway Obstruction by Swelling of Inner Wall of Armored Tube and Tracheal Laceration during Endoscopic Thyroidectomy

      한글로보기

      https://www.riss.kr/link?id=A104357725

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

      Recently, an endoscopic approach has been preferred for a thyroidectomy due to cosmetic considerations and the shortening of the hospital stay. An endotracheal tube may become obstructed by bending or compression due to changes in patient's position in the preperation for head and neck surgery. Therefore, the use of an armored tube has been increasing for this type of surgery. A new armored tube obstruction was experienced in a 27-years-old female patient with a thyroid adenoma, who underwent an endoscopic thyroidectomy. The swelling of a layer of the inner wall of the new armored tube was detected at about 10 cm, which caused an obstruction of 50% of the radius of the tube. Tracheal laceration also occurred during the operation, which was sutured under endoscopy; however, the stitches became unknotted in the recovery room, but were corrected by exploration.
      번역하기

      Recently, an endoscopic approach has been preferred for a thyroidectomy due to cosmetic considerations and the shortening of the hospital stay. An endotracheal tube may become obstructed by bending or compression due to changes in patient's position ...

      Recently, an endoscopic approach has been preferred for a thyroidectomy due to cosmetic considerations and the shortening of the hospital stay. An endotracheal tube may become obstructed by bending or compression due to changes in patient's position in the preperation for head and neck surgery. Therefore, the use of an armored tube has been increasing for this type of surgery. A new armored tube obstruction was experienced in a 27-years-old female patient with a thyroid adenoma, who underwent an endoscopic thyroidectomy. The swelling of a layer of the inner wall of the new armored tube was detected at about 10 cm, which caused an obstruction of 50% of the radius of the tube. Tracheal laceration also occurred during the operation, which was sutured under endoscopy; however, the stitches became unknotted in the recovery room, but were corrected by exploration.

      더보기

      참고문헌 (Reference)

      1 "Systemic and pulmonary changes with inhaled humid atmosphere:clinical application" 30 : 199-207, 1969

      2 "Perforation and partial obstruction of an armored endotracheal tube" 7 : 121-3, 1995

      3 "Partial endotracheal tube obstruction due to secretion" 43 : 371-4, 2002

      4 "Halothane depresses mucociliary flow in the trachea" 45 : 59-63, 1976

      5 "Endoscopic right thyroid lobectomy" 11 : 877-, 1997

      6 "Complete obstruction of an armored endotracheal tube" 53 : 624-5, 1974

      7 "Airway obstruction due to mucous plug during general inhalation anesthesia with double lumen endotracheal tube" 32 : 127-30, 1997

      8 "Airway obstruction by displaced cuff of armored tube" 1996

      9 "A clinical analysis of 100 cases of gasless endoscopic thyroidectomy" 63 : 18-22, 2002

      10 "A case report of airway obstruction with armored endotracheal tube" 29 : 438-41, 1995

      1 "Systemic and pulmonary changes with inhaled humid atmosphere:clinical application" 30 : 199-207, 1969

      2 "Perforation and partial obstruction of an armored endotracheal tube" 7 : 121-3, 1995

      3 "Partial endotracheal tube obstruction due to secretion" 43 : 371-4, 2002

      4 "Halothane depresses mucociliary flow in the trachea" 45 : 59-63, 1976

      5 "Endoscopic right thyroid lobectomy" 11 : 877-, 1997

      6 "Complete obstruction of an armored endotracheal tube" 53 : 624-5, 1974

      7 "Airway obstruction due to mucous plug during general inhalation anesthesia with double lumen endotracheal tube" 32 : 127-30, 1997

      8 "Airway obstruction by displaced cuff of armored tube" 1996

      9 "A clinical analysis of 100 cases of gasless endoscopic thyroidectomy" 63 : 18-22, 2002

      10 "A case report of airway obstruction with armored endotracheal tube" 29 : 438-41, 1995

      11 "A case report of airway obstruction with an armored endotracheal tube" 21 : 829-31, 1988

      12 "A case report of airway obstruction by reinforced endotracheal tube during surgery" 31 : 525-9, 1996

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 등재 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2013-11-27 학회명변경 한글명 : 대한마취과학회 -> 대한마취통증의학회 KCI등재
      2011-01-01 등재 등재학술지 유지 (등재유지) KCI등재
      2010-07-20 학술지명변경 한글명 : 대한마취과학회지 -> Korean Journal of Anesthesiology KCI등재
      2009-01-01 등재 등재학술지 유지 (등재유지) KCI등재
      2007-01-01 등재 등재 1차 FAIL (등재유지) KCI등재
      2004-01-01 등재 등재학술지 선정 (등재후보2차) KCI등재
      2003-01-01 등재 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2001-07-01 등재 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.09 0.09 0.1
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.09 0.09 0.27 0.01
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼