      Predictors and Clinical Impact of Inappropriate Implantable Cardioverter-Defibrillator Shocks in Korean Patients

      한글로보기

      https://www.riss.kr/link?id=A104784547

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Limited data are available on inappropriate shocks in Korean patients implanted with an implantable cardioverter-defibrillator (ICD). We investigated the impact of inappropriate shocks on clinical outcomes. This retrospective, single-center study included 148 patients treated between October 1999 and June 2011. The primary outcome was a composite event of all-cause mortality or hospitalization for any cardiac reason. The median followup duration was 29 months (interquartile range: 8 to 53). One or more inappropriate shocks occurred in 34 (23.0%) patients. A history of atrial fibrillation was the only independent predictor of inappropriate shock (hazard ratio [HR]: 4.16, 95% confidence interval [CI]: 1.89-9.15, P < 0.001). Atrial fibrillation was the most common cause of inappropriate shock (67.7%), followed by supraventricular tachycardia (23.5%), and abnormal sensing (8.8%). A composite event of all-cause mortality or hospitalizations for any cardiac reason during follow-up was not significantly different between patients with or without inappropriate shock (inappropriate shock vs no inappropriate shock: 35.3% vs 35.4%, adjusted HR: 1.06, 95% CI: 0.49-2.29, P = 0.877). Inappropriate shocks do not affect clinical outcomes in patients implanted with an ICD, although the incidence of inappropriate shocks is high.
      번역하기

      Limited data are available on inappropriate shocks in Korean patients implanted with an implantable cardioverter-defibrillator (ICD). We investigated the impact of inappropriate shocks on clinical outcomes. This retrospective, single-center study incl...

      Limited data are available on inappropriate shocks in Korean patients implanted with an implantable cardioverter-defibrillator (ICD). We investigated the impact of inappropriate shocks on clinical outcomes. This retrospective, single-center study included 148 patients treated between October 1999 and June 2011. The primary outcome was a composite event of all-cause mortality or hospitalization for any cardiac reason. The median followup duration was 29 months (interquartile range: 8 to 53). One or more inappropriate shocks occurred in 34 (23.0%) patients. A history of atrial fibrillation was the only independent predictor of inappropriate shock (hazard ratio [HR]: 4.16, 95% confidence interval [CI]: 1.89-9.15, P < 0.001). Atrial fibrillation was the most common cause of inappropriate shock (67.7%), followed by supraventricular tachycardia (23.5%), and abnormal sensing (8.8%). A composite event of all-cause mortality or hospitalizations for any cardiac reason during follow-up was not significantly different between patients with or without inappropriate shock (inappropriate shock vs no inappropriate shock: 35.3% vs 35.4%, adjusted HR: 1.06, 95% CI: 0.49-2.29, P = 0.877). Inappropriate shocks do not affect clinical outcomes in patients implanted with an ICD, although the incidence of inappropriate shocks is high.

      더보기

      참고문헌 (Reference)

      1 김용훈, "삽입형 심실제세동기 시술 환자의 임상적 특성" 대한심장학회 34 (34): 395-404, 2004

      2 Higgins SL, "Stability: an ICD detection criterion for discriminating atrial fibrillation from ventricular tachycardia" 6 : 1081-1088, 1995

      3 Auricchio A, "Safety, efficacy, and performance of new discrimination algorithms to reduce inappropriate and unnecessary shocks: the PainFree SST clinical study design" 13 : 1484-1493, 2011

      4 Marcus GM, "Recollection of pain due to inappropriate versus appropriate implantable cardioverter-defibrillator shocks" 34 : 348-353, 2011

      5 Schron EB, "Quality of life in the antiarrhythmics versus implantable defibrillators trial: impact of therapy and influence of adverse symptoms and defibrillator shocks" 105 : 589-594, 2002

      6 Keren A, "Psychological adjustment in ICD patients living with advisory fidelis leads" 22 : 57-63, 2011

      7 Gold MR, "Prospective comparison of discrimination algorithms to prevent inappropriate ICD therapy: primary results of the Rhythm ID Going Head to Head Trial" 9 : 370-377, 2012

      8 Kadish A, "Prophylactic defibrillator implantation in patients with nonischemic dilated cardiomyopathy" 350 : 2151-2158, 2004

      9 Poole JE, "Prognostic importance of defibrillator shocks in patients with heart failure" 359 : 1009-1017, 2008

      10 Lüderitz B, "Patient acceptance of the implantable cardioverter defibrillator in ventricular tachyarrhythmias" 16 : 1815-1821, 1993

      1 김용훈, "삽입형 심실제세동기 시술 환자의 임상적 특성" 대한심장학회 34 (34): 395-404, 2004

      2 Higgins SL, "Stability: an ICD detection criterion for discriminating atrial fibrillation from ventricular tachycardia" 6 : 1081-1088, 1995

      3 Auricchio A, "Safety, efficacy, and performance of new discrimination algorithms to reduce inappropriate and unnecessary shocks: the PainFree SST clinical study design" 13 : 1484-1493, 2011

      4 Marcus GM, "Recollection of pain due to inappropriate versus appropriate implantable cardioverter-defibrillator shocks" 34 : 348-353, 2011

      5 Schron EB, "Quality of life in the antiarrhythmics versus implantable defibrillators trial: impact of therapy and influence of adverse symptoms and defibrillator shocks" 105 : 589-594, 2002

      6 Keren A, "Psychological adjustment in ICD patients living with advisory fidelis leads" 22 : 57-63, 2011

      7 Gold MR, "Prospective comparison of discrimination algorithms to prevent inappropriate ICD therapy: primary results of the Rhythm ID Going Head to Head Trial" 9 : 370-377, 2012

      8 Kadish A, "Prophylactic defibrillator implantation in patients with nonischemic dilated cardiomyopathy" 350 : 2151-2158, 2004

      9 Poole JE, "Prognostic importance of defibrillator shocks in patients with heart failure" 359 : 1009-1017, 2008

      10 Lüderitz B, "Patient acceptance of the implantable cardioverter defibrillator in ventricular tachyarrhythmias" 16 : 1815-1821, 1993

      11 Lo R, "Optimal Programming of ICDs for Prevention of Appropriate and Inappropriate Shocks" 10 : 408-416, 2008

      12 Moss AJ, "Long-term clinical course of patients after termination of ventricular tachyarrhythmia by an implanted defibrillator" 110 : 3760-3765, 2004

      13 van Rees JB, "Inappropriate implantable cardioverter-defibrillator shocks: incidence, predictors, and impact on mortality" 57 : 556-562, 2011

      14 Daubert JP, "Inappropriate implantable cardioverter-defibrillator shocks in MADIT II: frequency, mechanisms, predictors, and survival impact" 51 : 1357-1365, 2008

      15 Moss AJ, "Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia" 335 : 1933-1940, 1996

      16 Cevik C, "Implantable cardioverter defibrillators and their role in heart failure progression" 11 : 710-715, 2009

      17 Germano JJ, "Frequency and causes of implantable cardioverter-defibrillator therapies: is device ther apy proarrhythmic?" 97 : 1255-1261, 2006

      18 Pil Sang Song, "Electrical Storms in Patients with an Implantable Cardioverter Defibrillator" 연세대학교의과대학 52 (52): 26-32, 2011

      19 Swerdlow CD, "Downloadable software algorithm reduces inappropriate shocks caused by implantable cardioverter-defibrillator lead fractures: a prospective study" 122 : 1449-1455, 2010

      20 Kühlkamp V, "Clinical experience with the new detection algorithms for atrial fibrillation of a defibrillator with dual chamber sensing and pacing" 10 : 905-915, 1999

      21 Bhavnani SP, "Association between statin therapy and reductions in atrial fibrillation or flutter and inappropriate shock therapy" 10 : 854-859, 2008

      22 Dichtl W, "Appropriate therapy but not inappropriate shocks predict survival in implantable cardioverter defibrillator patients" 34 : 433-436, 2011

      23 Kleemann T, "Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of >10 years" 115 : 2474-2480, 2007

      24 Bardy GH, "Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure" 352 : 225-237, 2005

      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2011-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2009-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2005-01-01 평가 SCI 등재 (등재유지) KCI등재
      2002-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      1999-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 1.48 0.37 1.06
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.85 0.75 0.691 0.11
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼