    양수발전소 발전-전동기 운전중 감시 시스템의 개발 = Development of On-Line Monitoring System for Pumped Storage Generator/Motor

    한글로보기

    https://www.riss.kr/link?id=A104287182

    • 0

      상세조회
    • 0

      다운로드
    서지정보 열기
    • 내보내기
    • 내책장담기
    • 공유하기
    • 오류접수

    부가정보

    다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

    On-line monitoring system(OMS) has been developed for the pumped storage generator/motor. The OMS is applied to diagnosis of the PD(partial discharge) activity of stator insulation, the shorted-turn of rotor winding and the variation of the air-gap between stator and rotor. The OMS consists of DAS(data acquisition system), main server system, gateway and display PC. The DAS measures the PD, the shorted-turn and air-gap from three sensors installed on the generator/motor. The gateway controls the data which sent by DAS. The main server system saves the data, analyzes the data and conducts the diagnostic algorithm. The display PC shows the diagnostic results of partial discharge, shorted-turn and air-gap. Field tests were conducted using PDA(partial discharge analyzer). The results of the OMS and PDA measurements can be directly correlated with normalized quantity number(NQN), PD magnitude(Qm) and PD pattern.
    번역하기

    On-line monitoring system(OMS) has been developed for the pumped storage generator/motor. The OMS is applied to diagnosis of the PD(partial discharge) activity of stator insulation, the shorted-turn of rotor winding and the variation of the air-gap be...

    On-line monitoring system(OMS) has been developed for the pumped storage generator/motor. The OMS is applied to diagnosis of the PD(partial discharge) activity of stator insulation, the shorted-turn of rotor winding and the variation of the air-gap between stator and rotor. The OMS consists of DAS(data acquisition system), main server system, gateway and display PC. The DAS measures the PD, the shorted-turn and air-gap from three sensors installed on the generator/motor. The gateway controls the data which sent by DAS. The main server system saves the data, analyzes the data and conducts the diagnostic algorithm. The display PC shows the diagnostic results of partial discharge, shorted-turn and air-gap. Field tests were conducted using PDA(partial discharge analyzer). The results of the OMS and PDA measurements can be directly correlated with normalized quantity number(NQN), PD magnitude(Qm) and PD pattern.

    더보기

    참고문헌 (Reference)

    1 김희동, "발전기 회전자 권선의 운전중 층간단락 탐지" 48c : 192-199, 1999

    2 E. Woschnagg, "Turbogenerator Field Winding Shorted Turn Detection by AC Flux Measurement IEEE Trans. on Energy Conversion" 9 : 427-431, 1994.

    3 G. C. Stone, "Partial Discharge Seminar" 1 : 56-78, 2001.

    4 H. G. Sedding et al, "On-Line Partial Discharge Measurements on Turbine Generator" CIGRE 1998.

    5 G. C. Stone, "On-Line Monitoring for Condition Assessment of Motor and Generator Stator Windings" 94-103, 1994.

    6 G. C. Stone, "Importance of Bandwidth in PD Measurement in Operating Motors and Generators" 7 (7): 6-11, 2000.

    7 I. M Culbert, "Handbook to assess the Insulation Condition of Large Rotating Machines" 16 : 3 5-5036 25328, 1989.

    8 W. McDermid, "Experience with Directional Couplers for Partial Discharge Measurements on Rotating Machines in Operation" 14 (14): 175-184, 1999.

    9 Hee-Dong Kim, "Analysis of Partial Discharge to High Voltage Motor Stator Windings" 340-343, 2001.

    10 V. Warren, "Advancements in Partial Discharge Analysis to Diagnose Stator Winding Problems" 497-500, 2000.

    1 김희동, "발전기 회전자 권선의 운전중 층간단락 탐지" 48c : 192-199, 1999

    2 E. Woschnagg, "Turbogenerator Field Winding Shorted Turn Detection by AC Flux Measurement IEEE Trans. on Energy Conversion" 9 : 427-431, 1994.

    3 G. C. Stone, "Partial Discharge Seminar" 1 : 56-78, 2001.

    4 H. G. Sedding et al, "On-Line Partial Discharge Measurements on Turbine Generator" CIGRE 1998.

    5 G. C. Stone, "On-Line Monitoring for Condition Assessment of Motor and Generator Stator Windings" 94-103, 1994.

    6 G. C. Stone, "Importance of Bandwidth in PD Measurement in Operating Motors and Generators" 7 (7): 6-11, 2000.

    7 I. M Culbert, "Handbook to assess the Insulation Condition of Large Rotating Machines" 16 : 3 5-5036 25328, 1989.

    8 W. McDermid, "Experience with Directional Couplers for Partial Discharge Measurements on Rotating Machines in Operation" 14 (14): 175-184, 1999.

    9 Hee-Dong Kim, "Analysis of Partial Discharge to High Voltage Motor Stator Windings" 340-343, 2001.

    10 V. Warren, "Advancements in Partial Discharge Analysis to Diagnose Stator Winding Problems" 497-500, 2000.

    더보기

    분석정보

    View

    상세정보조회

    0

    Usage

    원문다운로드

    0

    대출신청

    0

    복사신청

    0

    EDDS신청

    0

    동일 주제 내 활용도 TOP

    더보기

    주제

    연도별 연구동향

    연도별 활용동향

    연관논문

    연구자 네트워크맵

    공동연구자 (7)

    유사연구자 (20) 활용도상위20명

    인용정보 인용지수 설명보기

    학술지 이력

    학술지 이력
    연월일 이력구분 이력상세 등재구분
    2007-01-01 등재 학술지 통합(등재유지)
    2006-01-01 등재 등재학술지 유지(등재유지) KCI등재
    2004-01-01 등재 등재학술지 유지(등재유지) KCI등재
    2001-07-01 등재 등재학술지 선정(등재후보2차) KCI등재
    1999-01-01 등재 등재후보학술지 선정(신규평가) KCI등재후보
    더보기

    이 자료와 함께 이용한 RISS 자료

    나만을 위한 추천자료

    해외이동버튼