The purpose of this study was to observe the change of marginal distortion related to heat treatment and surface treatment in.
Thirty copings were made on the self-curing resin dies and twenty copings among them were treated by heat and surface grind...
The purpose of this study was to observe the change of marginal distortion related to heat treatment and surface treatment in.
Thirty copings were made on the self-curing resin dies and twenty copings among them were treated by heat and surface grinding. All copings were adapted on the respective dies and then were invested into the plastic boxes with tray resin. Both coping and die invested in tray resin were cut through labio-lingually by a separating disc.
This cross-cutting surface was ground and polished.
Specimens were mounted on a light microscope and photographed. Marginal discrepancies were measured on photographes by a scale.
The obtained results could be summarized in the followings :
1. In all metal copings, the distortion of cervical margin was shown after heat treatment and surface treatment.
2. There were no statistically significant differences in marginal fitness between shoulder and deep chamfer.
3. There were no statistically significant differences in marginal fitness between labial margin and lingual margin in one die.
4 . In case of the copings which were not treated with preheating and were treated with surface grinding, the marginal distortion shows a tendency to increase.