RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCOPUS

      임신초기 이상임신의 진단에서 혈중 hCG와 CA-125치의 의의 = Significance of Serum hCG and CA-125 Level for Detection of Abnormal Pregnancies in First Trimester Pregnancy

      한글로보기

      https://www.riss.kr/link?id=A3359219

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

      To evaluate the efficacy of ultrasound, serum hCG and CA-125 levels for early detection of abnormal pregnancy in the first trimester of pregnancy, we collected samples from 90 pregnant women who had vaginal spotting. Among them, 27 women continued their pregnancy normally and 63 women were confirmed as abnormal pregnancies pathologically-ectopic pregnancy (30), blight ovum (10), missed abortion (5), fetal demise (10) and molar pregnancy (8). The 95% cofidence interval of serum hCG level in normal pregnant women was 32,000mUI/ml to 398,000mIU/ml. Deversed rates of serum hCG level below 95% confidence interval were 93.8% in women with ectopic pregnancy, 100% in women with missed abortion and fetal demise and 60% in women with blighted ovum. Increased rate of serum hCG level above 95% confidence interval was 67.5% in women with molar pregnancy. The incidence of elevated serum CA-125 level above 35u/ml was 68% in normal pregnant women. The upper limit of 95% confidence interval of serum CA-125 level in normal pregnant women was 150u/ml. We noticed no significant difference of incidence of elevated CA-125 level above 35 u/ml between normal and abnormal pregnant women. Compared to normal pregnant women, however, significant increase of CA-125 level above 150u/ml in women with fetal demise was obtained.
      번역하기

      To evaluate the efficacy of ultrasound, serum hCG and CA-125 levels for early detection of abnormal pregnancy in the first trimester of pregnancy, we collected samples from 90 pregnant women who had vaginal spotting. Among them, 27 women continued the...

      To evaluate the efficacy of ultrasound, serum hCG and CA-125 levels for early detection of abnormal pregnancy in the first trimester of pregnancy, we collected samples from 90 pregnant women who had vaginal spotting. Among them, 27 women continued their pregnancy normally and 63 women were confirmed as abnormal pregnancies pathologically-ectopic pregnancy (30), blight ovum (10), missed abortion (5), fetal demise (10) and molar pregnancy (8). The 95% cofidence interval of serum hCG level in normal pregnant women was 32,000mUI/ml to 398,000mIU/ml. Deversed rates of serum hCG level below 95% confidence interval were 93.8% in women with ectopic pregnancy, 100% in women with missed abortion and fetal demise and 60% in women with blighted ovum. Increased rate of serum hCG level above 95% confidence interval was 67.5% in women with molar pregnancy. The incidence of elevated serum CA-125 level above 35u/ml was 68% in normal pregnant women. The upper limit of 95% confidence interval of serum CA-125 level in normal pregnant women was 150u/ml. We noticed no significant difference of incidence of elevated CA-125 level above 35 u/ml between normal and abnormal pregnant women. Compared to normal pregnant women, however, significant increase of CA-125 level above 150u/ml in women with fetal demise was obtained.

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼