RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재

      Reduction of Entrance Surface Dose Depending on Shielding Methods for Panoramagraphy

      한글로보기

      https://www.riss.kr/link?id=A103851892

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

      Panoramagraphy was the second most used intraoral radiography utilized in Korea, resulting in 17.8% in university dental hospitals, 24.8% in dental hospitals, and 31.4% in dental clinics. Depending on increased demand like orthodontics and implant, panoromagraphy tends to consistently increase.This study were used lead glasses and lead shielding to reduce unnecessary radiation to the eyeballs and thyroid. ESD was 41.4% when radiation was shielded with the lead glasses while reducing 47.3% of ESD by shielding the X-ray tube area with shielding lead. There was no statistically significant difference. The lead glasses is appropriated to reduce unnecessary radiation exposure to the eyeballs.
      번역하기

      Panoramagraphy was the second most used intraoral radiography utilized in Korea, resulting in 17.8% in university dental hospitals, 24.8% in dental hospitals, and 31.4% in dental clinics. Depending on increased demand like orthodontics and implant, pa...

      Panoramagraphy was the second most used intraoral radiography utilized in Korea, resulting in 17.8% in university dental hospitals, 24.8% in dental hospitals, and 31.4% in dental clinics. Depending on increased demand like orthodontics and implant, panoromagraphy tends to consistently increase.This study were used lead glasses and lead shielding to reduce unnecessary radiation to the eyeballs and thyroid. ESD was 41.4% when radiation was shielded with the lead glasses while reducing 47.3% of ESD by shielding the X-ray tube area with shielding lead. There was no statistically significant difference. The lead glasses is appropriated to reduce unnecessary radiation exposure to the eyeballs.

      더보기

      참고문헌 (Reference)

      1 김창규, "자체제작 Pb 밴딩을 이용한 피폭선량 감소" 한국디지털정책학회 11 (11): 269-273, 2013

      2 신귀순, "국내 치과방사선의 현황 및 이용 실태" 대한방사선과학회 33 (33): 109-120, 2010

      3 EK. Kim, "Use of radiation in the field of dental history and facts" Korea National Institute of Food and Drug Safety Evaluation 18 (18): 1-4, 2011

      4 최정현, "STUDY ON ENTRANCE SKIN DOSE AT PANORAMIC RADIOGRAPHY IN INCHEON, KOREA" 대한방사선방어학회 39 (39): 182-186, 2014

      5 Korea Ministry of Food and Drug Safety, "Radiation safety management series No.34, Pediatric Patient dose in General Imaging inspection recommended guidelines"

      6 HI. Kang, "Radiation for dental Imaging" Daihak Pub 195-196, 2013

      7 Von H. Whitley, "Photoionization of deep centers in Al2O3" 87 : 249-, 2000

      8 M.S. Akselroda, "Optically stimulated luminescence and its use in medical dosimetry" 41 (41): 78-99, 2007

      9 A.J.J. Bos, "High sensitivity thermoluminescence dosimetry" 184 : 3-28, 2001

      10 "Diagnostic x-ray equipment regulation on safety management" 2015

      1 김창규, "자체제작 Pb 밴딩을 이용한 피폭선량 감소" 한국디지털정책학회 11 (11): 269-273, 2013

      2 신귀순, "국내 치과방사선의 현황 및 이용 실태" 대한방사선과학회 33 (33): 109-120, 2010

      3 EK. Kim, "Use of radiation in the field of dental history and facts" Korea National Institute of Food and Drug Safety Evaluation 18 (18): 1-4, 2011

      4 최정현, "STUDY ON ENTRANCE SKIN DOSE AT PANORAMIC RADIOGRAPHY IN INCHEON, KOREA" 대한방사선방어학회 39 (39): 182-186, 2014

      5 Korea Ministry of Food and Drug Safety, "Radiation safety management series No.34, Pediatric Patient dose in General Imaging inspection recommended guidelines"

      6 HI. Kang, "Radiation for dental Imaging" Daihak Pub 195-196, 2013

      7 Von H. Whitley, "Photoionization of deep centers in Al2O3" 87 : 249-, 2000

      8 M.S. Akselroda, "Optically stimulated luminescence and its use in medical dosimetry" 41 (41): 78-99, 2007

      9 A.J.J. Bos, "High sensitivity thermoluminescence dosimetry" 184 : 3-28, 2001

      10 "Diagnostic x-ray equipment regulation on safety management" 2015

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 재인증평가 신청대상 (재인증)
      2020-01-01 평가 등재학술지 선정 (재인증) KCI등재
      2019-01-01 평가 등재후보학술지 유지 (계속평가) KCI등재후보
      2018-12-01 평가 등재후보로 하락 (계속평가) KCI등재후보
      2015-01-01 평가 등재학술지 선정 (계속평가) KCI등재
      2013-01-01 평가 등재후보학술지 유지 (기타) KCI등재후보
      2012-01-01 평가 등재후보학술지 유지 (기타) KCI등재후보
      2011-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2010-01-01 평가 등재후보 1차 FAIL (등재후보1차) KCI등재후보
      2009-01-01 평가 등재후보학술지 유지 (등재후보2차) KCI등재후보
      2008-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2007-05-08 학회명변경 한글명 : 대한방사선기술학회 -> 대한방사선과학회
      영문명 : Korean Society Of Radiologial Technology -> Korean Society of Radiological Science
      KCI등재후보
      2006-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.37 0.37 0.38
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.4 0.41 0.487 0.08
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼