RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재

      Safety and Efficacy of 6.2 mm Patellar Button in Resurfacing Less than 20 mm Thin Patella: A Matched Pair Analysis = Safety and Efficacy of 6.2 mm Patellar Button in Resurfacing Less than 20 mm Thin Patella: A Matched Pair Analysis

      한글로보기

      https://www.riss.kr/link?id=A105465242

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Purpose: Restoring the native patellar thickness after patellar resurfacing provides optimal function of the knee after arthroplasty and minimises complications related to the patellofemoral articulation. The aim of this study was to assess the useful...

      Purpose: Restoring the native patellar thickness after patellar resurfacing provides optimal function of the knee after arthroplasty and minimises complications related to the patellofemoral articulation. The aim of this study was to assess the usefulness of a thin patellar button (6.2 mm) in patients with a patella thickness of less than 20 mm during total knee arthroplasty.
      Materials and Methods: This is a retrospective case control study. A total of 54 female patients with an intraoperative patellar thickness of <20 mm, resurfaced with a patellar button of 6.2 mm in thickness were identified (group 1). They were matched with 54 patients with a patellar thickness of 20-23 mm, resurfaced with a patellar button of 8 mm (group 2), based on age, sex, body mass index, and deformity. A clinical and radiological evaluation was done at a minimum 2-year follow-up.
      Results: The preoperative mean patellar thickness was 18.94±1.07 mm and was restored to 19.06±0.79 mm in group 1, as compared to 21.63±0.99 mm and 21.72±0.99 mm in group 2. The mean postoperative range of motion was 122.22°±9.25° in group 1 and 123.52°±8.72° in group 2 (p=0.13). No patellar bone or button related complications were observed in any patient in either group.
      Conclusions: The 6.2 mm thin patella is useful to restore the native thickness in patients with a patellar thickness of less than 20 mm without risk of button fracture, loosening or overstuffing.

      더보기

      참고문헌 (Reference)

      1 Hozack WJ, "The patellar clunk syndrome: a complication of posterior stabilized total knee arthroplasty" (241) : 203-208, 1989

      2 Pierson JL, "The effect of stuffing the patellofemoral compartment on the outcome of total knee arthroplasty" 89 : 2195-2203, 2007

      3 Bengs BC, "The effect of patellar thickness on intraoperative knee flexion and patellar tracking in total knee arthroplasty" 21 : 650-655, 2006

      4 Meftah M, "The effect of patellar replacement technique on patellofemoral complications and anterior knee pain" 27 : 1075-1080, 2012

      5 Ewald FC, "The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system" (248) : 9-12, 1989

      6 Maniar RN, "Surgical technique: lateral retinaculum release in knee arthroplasty using a stepwise, outside-in technique" 470 : 2854-2863, 2012

      7 Camp CL, "Surgical technique for symmetric patellar resurfacing during total knee arthroplasty" 26 : 281-284, 2013

      8 Hosseinzadeh HRS, "Special considerations in Asian knee arthroplasty [Internet]"

      9 Jones AC, "Radiographic assessment of patellofemoral osteoarthritis" 52 : 655-658, 1993

      10 Gopinathan P, "Patello-femoral clunk syndrome-current concepts" 11 : 55-57, 2014

      1 Hozack WJ, "The patellar clunk syndrome: a complication of posterior stabilized total knee arthroplasty" (241) : 203-208, 1989

      2 Pierson JL, "The effect of stuffing the patellofemoral compartment on the outcome of total knee arthroplasty" 89 : 2195-2203, 2007

      3 Bengs BC, "The effect of patellar thickness on intraoperative knee flexion and patellar tracking in total knee arthroplasty" 21 : 650-655, 2006

      4 Meftah M, "The effect of patellar replacement technique on patellofemoral complications and anterior knee pain" 27 : 1075-1080, 2012

      5 Ewald FC, "The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system" (248) : 9-12, 1989

      6 Maniar RN, "Surgical technique: lateral retinaculum release in knee arthroplasty using a stepwise, outside-in technique" 470 : 2854-2863, 2012

      7 Camp CL, "Surgical technique for symmetric patellar resurfacing during total knee arthroplasty" 26 : 281-284, 2013

      8 Hosseinzadeh HRS, "Special considerations in Asian knee arthroplasty [Internet]"

      9 Jones AC, "Radiographic assessment of patellofemoral osteoarthritis" 52 : 655-658, 1993

      10 Gopinathan P, "Patello-femoral clunk syndrome-current concepts" 11 : 55-57, 2014

      11 Merican AM, "Patellar thickness and lateral retinacular release affects patellofemoral kinematics in total knee arthroplasty" 22 : 526-533, 2014

      12 Lie DT, "Patellar resection during total knee arthroplasty: effect on bone strain and fracture risk" 13 : 203-208, 2005

      13 Clarke H, "Patellar prosthesis design needs to be optimized for caucasian female patients" 95-B (95-B): 40-, 2013

      14 Hamilton WG, "Patellar cut and composite thickness: the influence on postoperative motion and complications in total knee arthroplasty" 32 : 1803-1807, 2017

      15 Hofmann AA, "Patellar component medialization in total knee arthroplasty" 12 : 155-160, 1997

      16 Nikolaus OB, "Lateral patellar facet impingement after primary total knee arthroplasty: it does exist" 29 : 970-976, 2014

      17 Pierce TP, "Is there an ideal patellar thickness following total knee arthroplasty?" 39 : 187-192, 2016

      18 Tanikawa H, "Influence of total knee arthroplasty on patellar kinematics and patellofemoral pressure" 32 : 280-285, 2017

      19 Hsu HC, "Influence of patellar thickness on patellar tracking and patellofemoral contact characteristics after total knee arthroplasty" 11 : 69-80, 1996

      20 Abolghasemian M, "Effect of patellar thickness on knee flexion in total knee arthroplasty: a biomechanical and experimental study" 29 : 80-84, 2014

      21 Lee QJ, "Effect of patellar thickness on early results of total knee replacement with patellar resurfacing" 22 : 3093-3099, 2014

      22 Reuben JD, "Effect of patella thickness on patella strain following total knee arthroplasty" 6 : 251-258, 1991

      23 Devers BN, "Does greater knee flexion increase patient function and satisfaction after total knee arthroplasty?" 26 : 178-186, 2011

      24 Kim TK, "Clinical implications of anthropometric patellar dimensions for TKA in Asians" 467 : 1007-1014, 2009

      25 Singh VK, "Atraumatic patellar prosthesis dislocation with patellar tendon injury following a total knee arthroplasty: a case report" 4 : 11-, 2010

      26 Dong-Kyoon Kim, "Are Korean Patients Different from Other Ethnic Groups in Total Knee Arthroplasty?" 대한슬관절학회 27 (27): 199-206, 2015

      27 Metsna V, "Anterior knee pain following total knee replacement correlates with the OARSI score of the cartilage of the patella" 85 : 427-432, 2014

      28 Strachan RK, "A technique of staged lateral release to correct patellar tracking in total knee arthroplasty" 24 : 735-742, 2009

      29 Na SE, "A new high-flexion knee scoring system to eliminate the ceiling effect" 470 : 584-593, 2012

      30 Seo JG, "A case-control study of spontaneous patellar fractures following primary total knee replacement" 94 : 908-913, 2012

      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2025 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2022-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2020-01-01 평가 등재학술지 유지 (재인증) KCI등재
      2017-01-01 평가 등재학술지 유지 (계속평가) KCI등재
      2014-01-01 평가 등재학술지 선정 (계속평가) KCI등재
      2013-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2012-05-14 학술지명변경 한글명 : 대한슬관절학회지 -> Knee Surgery and Related Research
      외국어명 : journal of korean knee society -> Knee Surgery and Related Research
      KCI등재후보
      2012-01-01 평가 등재후보학술지 유지 (기타) KCI등재후보
      2011-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2009-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.21 0.21 0.26
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.27 0.23 0.528 0.04
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼