RISS 학술연구정보서비스

검색

인기 검색어

    다국어 입력

    http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

    변환된 중국어를 복사하여 사용하시면 됩니다.

    예시)
    • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
    • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
    닫기
    KCI등재 SCOPUS

    Correlation Between Bowel Preparation and the Adenoma Detection Rate in Screening Colonoscopy

    한글로보기

    https://www.riss.kr/link?id=A105116115

    • 0

      상세조회
    • 0

      다운로드
    서지정보 열기
    • 내보내기
    • 내책장담기
    • 공유하기
    • 오류접수
    인용문이 복사되었습니다.

    부가정보

    다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

    Purpose: The adenoma detection rate is commonly used as a measure of the quality of colonoscopy. This study assessed both the association between the adenoma detection rate and the quality of bowel preparation and the risk factors associated with the adenoma detection rate in screening colonoscopy.
    Methods: This retrospective analysis involved 1,079 individuals who underwent screening colonoscopy at the National Cancer Center between December 2012 and April 2014. Bowel preparation was classified by using the Aronchick scale. Individuals with inadequate bowel preparations (n = 47, 4.4%) were excluded because additional bowel preparation was needed. The results of 1,032 colonoscopies were included in the analysis.
    Results: The subjects’ mean age was 53.1 years, and 657 subjects (63.7%) were men. The mean cecal intubation time was 6.7 minutes, and the mean withdrawal time was 8.7 minutes. The adenoma and polyp detection rates were 28.1% and 41.8%, respectively. The polyp, adenoma, and advanced adenoma detection rates did not correlate with the quality of bowel preparation. The multivariate analysis showed age ≥ 60 years (hazard ratio [HR], 1.42; 95% confidence interval [CI], 1.02–1.97; P = 0.040), body mass index ≥ 25 kg/m2 (HR, 1.56; 95% CI, 1.17–2.08; P = 0.002) and current smoking (HR, 1.44; 95% CI, 1.01–2.06; P = 0.014) to be independent risk factors for adenoma detection.
    Conclusion: The adenoma detection rate was unrelated to the quality of bowel preparation for screening colonoscopy. Older age, obesity, and smoking were independent risk factors for adenoma detection.
    번역하기

    Purpose: The adenoma detection rate is commonly used as a measure of the quality of colonoscopy. This study assessed both the association between the adenoma detection rate and the quality of bowel preparation and the risk factors associated with the ...

    Purpose: The adenoma detection rate is commonly used as a measure of the quality of colonoscopy. This study assessed both the association between the adenoma detection rate and the quality of bowel preparation and the risk factors associated with the adenoma detection rate in screening colonoscopy.
    Methods: This retrospective analysis involved 1,079 individuals who underwent screening colonoscopy at the National Cancer Center between December 2012 and April 2014. Bowel preparation was classified by using the Aronchick scale. Individuals with inadequate bowel preparations (n = 47, 4.4%) were excluded because additional bowel preparation was needed. The results of 1,032 colonoscopies were included in the analysis.
    Results: The subjects’ mean age was 53.1 years, and 657 subjects (63.7%) were men. The mean cecal intubation time was 6.7 minutes, and the mean withdrawal time was 8.7 minutes. The adenoma and polyp detection rates were 28.1% and 41.8%, respectively. The polyp, adenoma, and advanced adenoma detection rates did not correlate with the quality of bowel preparation. The multivariate analysis showed age ≥ 60 years (hazard ratio [HR], 1.42; 95% confidence interval [CI], 1.02–1.97; P = 0.040), body mass index ≥ 25 kg/m2 (HR, 1.56; 95% CI, 1.17–2.08; P = 0.002) and current smoking (HR, 1.44; 95% CI, 1.01–2.06; P = 0.014) to be independent risk factors for adenoma detection.
    Conclusion: The adenoma detection rate was unrelated to the quality of bowel preparation for screening colonoscopy. Older age, obesity, and smoking were independent risk factors for adenoma detection.

    더보기

    참고문헌 (Reference)

    1 Clark BT, "What level of bowel prep quality requires early repeat colonoscopy: systematic review and meta-analysis of the impact of preparation quality on adenoma detection rate" 109 : 1714-1723, 2014

    2 Sherer EA, "The effect of colonoscopy preparation quality on adenoma detection rates" 75 : 545-553, 2012

    3 Kaminski MF, "Quality indicators for colonoscopy and the risk of interval cancer" 362 : 1795-1803, 2010

    4 Rex DK, "Quality indicators for colonoscopy" 101 : 873-885, 2006

    5 Rex DK, "Quality in the technical performance of colonoscopy and the continuous quality improvement process for colonoscopy: recommendations of the U.S. Multi-Society Task Force on Colorectal Cancer" 97 : 1296-1308, 2002

    6 Winawer SJ, "Prevention of colorectal cancer by colonoscopic polypectomy. The National Polyp Study Workgroup" 329 : 1977-1981, 1993

    7 Lorenzo-Zúñiga V, "Preparation for colonoscopy: types of scales and cleaning products" 104 : 426-431, 2012

    8 Schramm C, "Patient- and procedure-related factors affecting proximal and distal detection rates for polyps and adenomas: results from 1603 screening colonoscopies" 30 : 1715-1722, 2015

    9 Adler A, "Narrow-band versus white-light high definition television endoscopic imaging for screening colonoscopy: a prospective randomized trial" 136 : 410-6.e1-, 2009

    10 Hassan C, "Impact of lifestyle factors on colorectal polyp detection in the screening setting" 53 : 1328-1333, 2010

    1 Clark BT, "What level of bowel prep quality requires early repeat colonoscopy: systematic review and meta-analysis of the impact of preparation quality on adenoma detection rate" 109 : 1714-1723, 2014

    2 Sherer EA, "The effect of colonoscopy preparation quality on adenoma detection rates" 75 : 545-553, 2012

    3 Kaminski MF, "Quality indicators for colonoscopy and the risk of interval cancer" 362 : 1795-1803, 2010

    4 Rex DK, "Quality indicators for colonoscopy" 101 : 873-885, 2006

    5 Rex DK, "Quality in the technical performance of colonoscopy and the continuous quality improvement process for colonoscopy: recommendations of the U.S. Multi-Society Task Force on Colorectal Cancer" 97 : 1296-1308, 2002

    6 Winawer SJ, "Prevention of colorectal cancer by colonoscopic polypectomy. The National Polyp Study Workgroup" 329 : 1977-1981, 1993

    7 Lorenzo-Zúñiga V, "Preparation for colonoscopy: types of scales and cleaning products" 104 : 426-431, 2012

    8 Schramm C, "Patient- and procedure-related factors affecting proximal and distal detection rates for polyps and adenomas: results from 1603 screening colonoscopies" 30 : 1715-1722, 2015

    9 Adler A, "Narrow-band versus white-light high definition television endoscopic imaging for screening colonoscopy: a prospective randomized trial" 136 : 410-6.e1-, 2009

    10 Hassan C, "Impact of lifestyle factors on colorectal polyp detection in the screening setting" 53 : 1328-1333, 2010

    11 Harewood GC, "Impact of colonoscopy preparation quality on detection of suspected colonic neoplasia" 58 : 76-79, 2003

    12 Froehlich F, "Impact of colonic cleansing on quality and diagnostic yield of colonoscopy: the European Panel of Appropriateness of Gastrointestinal Endoscopy European multicenter study" 61 : 378-384, 2005

    13 Kim JS, "Impact of bowel preparation quality on adenoma identification during colonoscopy and optimal timing of surveillance" 60 : 3092-3099, 2015

    14 Lieberman DA, "Guidelines for colonoscopy surveillance after screening and polypectomy: a consensus update by the US Multi-Society Task Force on Colorectal Cancer" 143 : 844-857, 2012

    15 Calderwood AH, "Good is better than excellent: bowel preparation quality and adenoma detection rates" 81 : 691-9.e1-, 2015

    16 Adler A, "Factors determining the quality of screening colonoscopy: a prospective study on adenoma detection rates, from 12,134 examinations (Berlin colonoscopy project 3, BECOP-3)" 62 : 236-241, 2013

    17 Barret M, "Factors associated with adenoma detection rate and diagnosis of polyps and colorectal cancer during colonoscopy in France: results of a prospective, nationwide survey" 8 : e68947-, 2013

    18 Rai T, "Effect of quality of bowel preparation on quality indicators of adenoma detection rates and colonoscopy completion rates" 4 : 148-153, 2016

    19 Jacob BJ, "Effect of colonoscopy on colorectal cancer incidence and mortality: an instrumental variable analysis" 76 : 355-64.e1-, 2012

    20 Bretagne JF, "Do we need to embrace adenoma detection rate as the main quality control parameter during colonoscopy?" 40 : 523-528, 2008

    21 Barclay RL, "Colonoscopic withdrawal times and adenoma detection during screening colonoscopy" 355 : 2533-2541, 2006

    22 Zauber AG, "Colonoscopic polypectomy and long-term prevention of colorectal-cancer deaths" 366 : 687-696, 2012

    23 Lee TJ, "Colonoscopic factors associated with adenoma detection in a national colorectal cancer screening program" 46 : 203-211, 2014

    24 Martínez ME, "Cigarette smoking and alcohol consumption as risk factors for colorectal adenomatous polyps" 87 : 274-279, 1995

    25 정규원, "Cancer Statistics in Korea: Incidence, Mortality, Survival, and Prevalence in 2012" 대한암학회 47 (47): 127-141, 2015

    26 Okabayashi K, "Body mass index category as a risk factor for colorectal adenomas: a systematic review and meta-analysis" 107 : 1175-1185, 2012

    27 Coe SG, "An endoscopic quality improvement program improves detection of colorectal adenomas" 108 : 219-226, 2013

    28 Millan MS, "Adenoma detection rate: the real indicator of quality in colonoscopy" 51 : 1217-1220, 2008

    29 Tholey DM, "Adenoma detection in excellent versus good bowel preparation for colonoscopy" 49 : 313-319, 2015

    30 Wexner SD, "A consensus document on bowel preparation before colonoscopy: prepared by a task force from the American Society of Colon and Rectal Surgeons (ASCRS), the American Society for Gastrointestinal Endoscopy (ASGE), and the Society of American Gastrointestinal and Endoscopic Surgeons (SAGES)" 63 : 894-909, 2006

    더보기

    동일학술지(권/호) 다른 논문

    분석정보

    View

    상세정보조회

    0

    Usage

    원문다운로드

    0

    대출신청

    0

    복사신청

    0

    EDDS신청

    0

    동일 주제 내 활용도 TOP

    더보기

    주제

    연도별 연구동향

    연도별 활용동향

    연관논문

    연구자 네트워크맵

    공동연구자 (7)

    유사연구자 (20) 활용도상위20명

    인용정보 인용지수 설명보기

    학술지 이력

    학술지 이력
    연월일 이력구분 이력상세 등재구분
    2023 평가 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
    2020-01-01 등재 등재학술지 유지 (해외등재 학술지 평가) KCI등재
    2013-03-13 학술지명변경 한글명 : Journal of the Korean Society of Coloproctolgy -> Annals of Coloproctolgy
    외국어명 : Journal of the Korean Society of Coloproctolgy -> Annals of Coloproctolgy
    KCI등재
    2011-01-01 등재 등재학술지 유지 (등재유지) KCI등재
    2010-11-26 학술지명변경 한글명 : 대한대장항문학회지 -> Journal of the Korean Society of Coloproctolgy KCI등재
    2009-01-01 등재 등재학술지 유지 (등재유지) KCI등재
    2006-01-01 등재 등재학술지 선정 (등재후보2차) KCI등재
    2005-05-30 학술지등록 한글명 : 대한대장항문학회지
    외국어명 : 미등록
    KCI등재후보
    2005-01-01 등재 등재후보 1차 PASS (등재후보1차) KCI등재후보
    2003-07-01 등재 등재후보학술지 선정 (신규평가) KCI등재후보
    더보기

    학술지 인용정보

    학술지 인용정보
    기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
    2016 0.09 0.09 0.08
    KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
    0.07 0.06 0.312 0
    더보기

    이 자료와 함께 이용한 RISS 자료

    나만을 위한 추천자료

    해외이동버튼