      웨플형 핀-관 열교환기의 습표면 성능시험 = Wet surface performance test of waffle type heat exchanger

      한글로보기

      https://www.riss.kr/link?id=E805724

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

      In this study, the wet surface heat transfer coefficients and friction factor of waffle type heat exchangers are presented. Three samples with different fin pitch(2.02mm, 1.97mm, 1.90mm) tested. Tests were conducted in a open loop wind tunnel. The wet surface heat transfer coefficient was reduced following the procedure given in ARI 410-81. Results showed that the heat transfer coefficients of the heat exchanger with 2.02mm fin pitch were slighly lower than those with 1.97mm and 1.90mm fin pitch. The heat transfer coefficients of the heat exchanger with 1.97mm fin pitch were approximately the same as those with 1.90mm fin pitch. The effect of refrigerant circuit was also investigated. Results show that the effect of the refrigerant circuit on the wet surface performance is not significant.
      번역하기

      In this study, the wet surface heat transfer coefficients and friction factor of waffle type heat exchangers are presented. Three samples with different fin pitch(2.02mm, 1.97mm, 1.90mm) tested. Tests were conducted in a open loop wind tunnel. The wet...

      In this study, the wet surface heat transfer coefficients and friction factor of waffle type heat exchangers are presented. Three samples with different fin pitch(2.02mm, 1.97mm, 1.90mm) tested. Tests were conducted in a open loop wind tunnel. The wet surface heat transfer coefficient was reduced following the procedure given in ARI 410-81. Results showed that the heat transfer coefficients of the heat exchanger with 2.02mm fin pitch were slighly lower than those with 1.97mm and 1.90mm fin pitch. The heat transfer coefficients of the heat exchanger with 1.97mm fin pitch were approximately the same as those with 1.90mm fin pitch. The effect of refrigerant circuit was also investigated. Results show that the effect of the refrigerant circuit on the wet surface performance is not significant.

      더보기

      목차 (Table of Contents)

      • 1. 서론
      • 2. 실험 장치
      • 3. 습표면 열전달계수
      • 4. 실험결과
      • 5. 결론
      • 1. 서론
      • 2. 실험 장치
      • 3. 습표면 열전달계수
      • 4. 실험결과
      • 5. 결론
      • 참고문헌