RISS 학술연구정보서비스

검색

인기 검색어

    다국어 입력

    http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

    변환된 중국어를 복사하여 사용하시면 됩니다.

    예시)
    • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
    • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
    닫기
    KCI등재

    직류와 60 Hz 교류가 중첩된 전압에 대한 산화아연 피뢰기 소자의 누설전류 특성 = Characteristics of ZnO Arrester Blocks Leakage Currents under Mixed Direct and 60 Hz Alternating Voltages

    한글로보기

    https://www.riss.kr/link?id=A104287108

    • 0

      상세조회
    • 0

      다운로드
    서지정보 열기
    • 내보내기
    • 내책장담기
    • 공유하기
    • 오류접수

    부가정보

    다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

    This paper presents the characteristics of leakage currents flowing through ZinC Oxide(ZnO) surge arrester blocks under mixed direct and 60 ㎐ alternating voltages. A mixed voltage, in which an alternating voltage is superimposed upon a direct voltage, appears on the HVDC system network. The mixed direct and alternating voltage generator with a peak open-circuit of 10 ㎸ was designed and fabricated. The leakage currents and V-I curves for the fine and used ZnO surge arrester blocks were measured as a function of the voltage ratio k, where the voltage ratio k is defined as the ratio of the peak of alternating voltage to the peak of the mixed voltages. The resistive component in the leakage current in the low conduction region is significantly increased with increasing the voltage ratio k. The V-I characteristic curves for the mixed voltages lies between the direct and alternating characteristics, and the cross-over phenomenon in the high conduction region was appeared.
    번역하기

    This paper presents the characteristics of leakage currents flowing through ZinC Oxide(ZnO) surge arrester blocks under mixed direct and 60 ㎐ alternating voltages. A mixed voltage, in which an alternating voltage is superimposed upon a direct voltag...

    This paper presents the characteristics of leakage currents flowing through ZinC Oxide(ZnO) surge arrester blocks under mixed direct and 60 ㎐ alternating voltages. A mixed voltage, in which an alternating voltage is superimposed upon a direct voltage, appears on the HVDC system network. The mixed direct and alternating voltage generator with a peak open-circuit of 10 ㎸ was designed and fabricated. The leakage currents and V-I curves for the fine and used ZnO surge arrester blocks were measured as a function of the voltage ratio k, where the voltage ratio k is defined as the ratio of the peak of alternating voltage to the peak of the mixed voltages. The resistive component in the leakage current in the low conduction region is significantly increased with increasing the voltage ratio k. The V-I characteristic curves for the mixed voltages lies between the direct and alternating characteristics, and the cross-over phenomenon in the high conduction region was appeared.

    더보기

    참고문헌 (Reference)

    1 이복희, "산화아연 피뢰기소자에 흐르는 저항분 누설전류의 검출기법" 15 (15): 67-73, 2001

    2 이복희, "고전압대전류공학" 청문각 223-226, 2001

    3 Haddad, "ZnO surge arrester elements with mixed direct and 50 Hz voltages" 138 (138): 265-272, 1991.

    4 J. Lundquist, "New method for measurement of resistive leakage currents of metal-oxide surge arrester in service" pd-5 (pd-5): 1811-1822, 1990.

    5 M. Oyama, "Life performance of zinc-oxide elements under DC voltage" pas-101 (pas-101): 1364-1368, 1982.

    6 A. Haddad, "Characteristics of ZnO surge arrester elements with direct and power frequency voltages" 137 (137): 269-279, 1990.

    7 W. G. carlson, "A procedure for estimating the life time of gapless metal oxide surge arresters for AC application" pwrd-1 (pwrd-1): 67-74, 1986.

    8 Bok-Hee Lee, "A Monitoring Device of Leakage Currents Flowing through ZnO Surge Arresters" 42, Pt.1 (42, Pt.1): 1568-1574, 2003

    1 이복희, "산화아연 피뢰기소자에 흐르는 저항분 누설전류의 검출기법" 15 (15): 67-73, 2001

    2 이복희, "고전압대전류공학" 청문각 223-226, 2001

    3 Haddad, "ZnO surge arrester elements with mixed direct and 50 Hz voltages" 138 (138): 265-272, 1991.

    4 J. Lundquist, "New method for measurement of resistive leakage currents of metal-oxide surge arrester in service" pd-5 (pd-5): 1811-1822, 1990.

    5 M. Oyama, "Life performance of zinc-oxide elements under DC voltage" pas-101 (pas-101): 1364-1368, 1982.

    6 A. Haddad, "Characteristics of ZnO surge arrester elements with direct and power frequency voltages" 137 (137): 269-279, 1990.

    7 W. G. carlson, "A procedure for estimating the life time of gapless metal oxide surge arresters for AC application" pwrd-1 (pwrd-1): 67-74, 1986.

    8 Bok-Hee Lee, "A Monitoring Device of Leakage Currents Flowing through ZnO Surge Arresters" 42, Pt.1 (42, Pt.1): 1568-1574, 2003

    더보기

    분석정보

    View

    상세정보조회

    0

    Usage

    원문다운로드

    0

    대출신청

    0

    복사신청

    0

    EDDS신청

    0

    동일 주제 내 활용도 TOP

    더보기

    주제

    연도별 연구동향

    연도별 활용동향

    연관논문

    연구자 네트워크맵

    공동연구자 (7)

    유사연구자 (20) 활용도상위20명

    인용정보 인용지수 설명보기

    학술지 이력

    학술지 이력
    연월일 이력구분 이력상세 등재구분
    2007-01-01 등재 학술지 통합(등재유지)
    2006-01-01 등재 등재학술지 유지(등재유지) KCI등재
    2004-01-01 등재 등재학술지 유지(등재유지) KCI등재
    2001-07-01 등재 등재학술지 선정(등재후보2차) KCI등재
    1999-01-01 등재 등재후보학술지 선정(신규평가) KCI등재후보
    더보기

    이 자료와 함께 이용한 RISS 자료

    나만을 위한 추천자료

    해외이동버튼