      측정방법에 따른 치과용 수경성 시멘트의 경화시간 = Setting time of dental water-based luting cements under various test variables

      한글로보기

      https://www.riss.kr/link?id=A19662434

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Information on setting behavior of luting cements is essential to accomplish successful cementation of dental restoration. The purpose of this study is to investigate the influence of test variables on the setting time of dental water-based luting cements. Six kinds of luting cements were investigated: two zinc phosphate, two zinc polycarboxylate and two glass ionomer cements. Cements were mixed with the standard consistency for luting according to their respective manufacturer's recommendation. Setting time of cements was measured with two test apparatus (penetrating indentor and oscillating rheometer) under one of following environmental conditions (temperature/humidity); 37℃/90%, 23℃/50% and 37℃/20%. The Setting time was recorded as the time elapsed from start of mixing to the time indicated at the ISO specification (9917:1991) or when the oscillation is reduced to 95% of the original width. Setting time of luting cements was decreased with increase in temperature and decrease in humidity, and it was significantly influenced by environmental temperature and humidity. Some cements tested showed significant differences in setting time measured between indentor and rheometer under laboratory environment. Percent water loss of cements was different under various environmental conditions. This was largely arisen at the early stage of setting. Zinc Phosphate was hygroscopic under high humidity. these results indicate that working and setting time should be separately evaluated in office and oral environments, respectively. Oscillating rheometer was useful to investigate setting behavior of dental water-based luting cement. However, control of test environment and sensitivity should be considered in the rheometry.
      번역하기

      Information on setting behavior of luting cements is essential to accomplish successful cementation of dental restoration. The purpose of this study is to investigate the influence of test variables on the setting time of dental water-based luting cem...

      Information on setting behavior of luting cements is essential to accomplish successful cementation of dental restoration. The purpose of this study is to investigate the influence of test variables on the setting time of dental water-based luting cements. Six kinds of luting cements were investigated: two zinc phosphate, two zinc polycarboxylate and two glass ionomer cements. Cements were mixed with the standard consistency for luting according to their respective manufacturer's recommendation. Setting time of cements was measured with two test apparatus (penetrating indentor and oscillating rheometer) under one of following environmental conditions (temperature/humidity); 37℃/90%, 23℃/50% and 37℃/20%. The Setting time was recorded as the time elapsed from start of mixing to the time indicated at the ISO specification (9917:1991) or when the oscillation is reduced to 95% of the original width. Setting time of luting cements was decreased with increase in temperature and decrease in humidity, and it was significantly influenced by environmental temperature and humidity. Some cements tested showed significant differences in setting time measured between indentor and rheometer under laboratory environment. Percent water loss of cements was different under various environmental conditions. This was largely arisen at the early stage of setting. Zinc Phosphate was hygroscopic under high humidity. these results indicate that working and setting time should be separately evaluated in office and oral environments, respectively. Oscillating rheometer was useful to investigate setting behavior of dental water-based luting cement. However, control of test environment and sensitivity should be considered in the rheometry.

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼