RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCOPUS

      The Current Status of SPECT or SPECT/CT in South Korea

      한글로보기

      https://www.riss.kr/link?id=A103552090

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      The first step to nuclear medicine in Korea startedwith introduction of the gamma camera in 1969. Althoughplanar images with the gamma camera give important functionalinformation, they have the limitations that result from 2-dimensional images. Single...

      The first step to nuclear medicine in Korea startedwith introduction of the gamma camera in 1969. Althoughplanar images with the gamma camera give important functionalinformation, they have the limitations that result from 2-dimensional images. Single-photon emission computed tomography(SPECT) due to its 3-dimensional image acquisition issuperior to earlier planar gamma imaging in image resolutionand diagnostic accuracy. As demand for a hybrid functional andanatomical imaging device has increased, integrated SPECT/CT systems have been used. In Korea, SPECT/CT was for thefirst time installed in 2003. SPECT/CT can eliminate manypossible pitfalls on SPECT-alone images, making better attenuationcorrection and thereby improving image quality.
      Therefore, SPECT/CT is clinically preferred in many hospitalsin various aspects.More recently, additional SPECT/CT imagestaken from the region with equivocal uptake on planar imageshave been helpful in making precise interpretation as part oftheir clinical workup in postoperative thyroid cancer patients.
      SPECT and SPECT/CT have various advantages, but its clinicalapplication has gradually decreased in recent few years.
      While some researchers investigated the myocardial blood flowwith cardiac PET using F-18 FDG or N-13 ammonia, myocardialperfusion SPECT is, at present, the radionuclide imagingstudy of choice for the risk stratification and guiding therapy inthe coronary artery disease patients in Korea. New diagnosticradiopharmaceuticals for AD have received increasingattention; nevertheless, brain SPECT will remain the most reliablemodality evaluating cerebral perfusion.

      더보기

      참고문헌 (Reference)

      1 김재승, "도파민 운반체 영상의 임상이용을 위한 실제적 접근" 대한핵의학회 42 (42): 425-432, 2008

      2 Xue YL, "Value of(131)I SPECT/CT for the evaluation of differentiated thyroid cancer : a systematic review of the literature" 40 : 768-778, 2013

      3 권수현, "The Utility of Segmental Analysis in Cardiac I-123MIBG SPECT in Parkinson’s Disease" 대한핵의학회 49 (49): 298-302, 2015

      4 나창주, "The Clinical Value of Hybrid Sentinel Lymphoscintigraphy to Predict Metastatic Sentinel Lymph Nodes in Breast Cancer" 대한핵의학회 49 (49): 26-32, 2015

      5 Medicine TPCottAoKSoN, "The 50th Anniversary of the Korean Society of Nuclear Medicine" 2011

      6 Linke R, "Skeletal SPECT/CT of the peripheral extremities" 194 : W329-W335, 2010

      7 Raynaud C, "SPECTanalysis of recent cerebral infarction" 20 : 192-204, 1989

      8 Even-Sapir E, "SPECT/multislice low-dose CT : a clinically relevant constituent in the imaging algorithm of nononcologic patients referred for bone scintigraphy" 48 : 319-324, 2007

      9 Krausz Y, "SPECT/CT hybrid imaging with 111In-pentetreotide in assessment of neuroendocrine tumours" 59 : 565-573, 2003

      10 Berman D, "Risk stratification in coronary artery disease : implications for stabilization and prevention" 79 : 10-16, 1997

      1 김재승, "도파민 운반체 영상의 임상이용을 위한 실제적 접근" 대한핵의학회 42 (42): 425-432, 2008

      2 Xue YL, "Value of(131)I SPECT/CT for the evaluation of differentiated thyroid cancer : a systematic review of the literature" 40 : 768-778, 2013

      3 권수현, "The Utility of Segmental Analysis in Cardiac I-123MIBG SPECT in Parkinson’s Disease" 대한핵의학회 49 (49): 298-302, 2015

      4 나창주, "The Clinical Value of Hybrid Sentinel Lymphoscintigraphy to Predict Metastatic Sentinel Lymph Nodes in Breast Cancer" 대한핵의학회 49 (49): 26-32, 2015

      5 Medicine TPCottAoKSoN, "The 50th Anniversary of the Korean Society of Nuclear Medicine" 2011

      6 Linke R, "Skeletal SPECT/CT of the peripheral extremities" 194 : W329-W335, 2010

      7 Raynaud C, "SPECTanalysis of recent cerebral infarction" 20 : 192-204, 1989

      8 Even-Sapir E, "SPECT/multislice low-dose CT : a clinically relevant constituent in the imaging algorithm of nononcologic patients referred for bone scintigraphy" 48 : 319-324, 2007

      9 Krausz Y, "SPECT/CT hybrid imaging with 111In-pentetreotide in assessment of neuroendocrine tumours" 59 : 565-573, 2003

      10 Berman D, "Risk stratification in coronary artery disease : implications for stabilization and prevention" 79 : 10-16, 1997

      11 Jimenez-Heffernan A, "Results of a prospective International Atomic Energy Ahency(IAEA)sentinel node trial on the value of SPECT/CT over planar imaging in various malignancies" 56 : 1338-1344, 2015

      12 Hougaard K, "Regional cerebral blood flow in focal cortical epilepsy" 33 : 527-535, 1976

      13 Avram AM, "Radioiodine scintigraphy with SPECT/CT : an important diagnostic tool for thyroid cancer staging and risk stratification" 42 : 170-180, 2014

      14 Shaw LJ, "Prognostic value of normal exercise and adenosine(99m)Tc-tetrofosmin SPECT imaging : results from the multicenter registry of 4728 patients" 44 : 134-139, 2003

      15 최홍윤, "Parametric Cerebrovascular Reserve Images Using Acetazolamide 99mTc-HMPAO SPECT: A Feasibility Study of Quantitative Assessment" 대한핵의학회 47 (47): 188-195, 2013

      16 Jacobson AF, "Myocardial iodine-123 meta-iodobenzylguanidine imaging and cardiac events in heart failure. Results of the prospective ADMIRE-HF (AdreView Myocardial Imaging for Risk Evaluation in Heart Failure) study" 55 : 2212-2221, 2010

      17 Berman DS, "Incremental value of prognostic testing in patients with known or suspected ischemic heart disease : a basis for optimal utilization of exercise technetium-99m sestamibi myocardial perfusion single-photon emission computed tomography" 26 : 639-647, 1995

      18 "Data library on Nuclear Medicine Facilities and Procedures in Korea" The Korean Society of Nuclear Medicine

      19 Lee DS, "Comparison of the cost-effectiveness of stress myocardial SPECT and stress echocardiography in suspected coronary artery disease considering the prognostic value of false-negative results" 9 : 515-522, 2002

      20 Van Binnebeek S, "Comparison of diagnostic accuracy of Inpentetreotide SPECT and Ga-DOTATOC PET/CT : a lesion-bylesion analysis in patients with metastatic neuroendocrine tumours" 26 : 900-909, 2016

      21 Patterson RE, "Comparison of costeffectiveness and utility of exercise ECG, single photon emission computed tomography, positron emission tomography, and coronary angiography for diagnosis of coronary artery disease" 91 : 54-65, 1995

      22 Oh JK, "Comparison of I-123 MIBG planar imaging and SPECT for the detection of decreased heart uptake in Parkinson disease" 2015

      23 이인기, "Comparison of Diagnostic Sensitivity and Quantitative Indices Between 68Ga-DOTATOC PET/CT and 111In-Pentetreotide SPECT/CT in Neuroendocrine Tumors: a Preliminary Report" 대한핵의학회 49 (49): 284-290, 2015

      24 Huellner MW, "Clinical applications of SPECT/CT in imaging the extremities" 41 (41): S50-S58, 2014

      25 Boogers MJ, "Cardiac sympathetic denervation assessed with 123-iodine metaiodobenzylguanidine imaging predicts ventricular arrhythmias in implantable cardioverterdefibrillator patients" 55 : 2769-2777, 2010

      26 Marshall A, "Cardiac iodine-123 metaiodobenzylguanidine imaging predicts ventricular arrhythmia in heart failure patients receiving an implantable cardioverter-defibrillator for primary prevention" 98 : 1359-1365, 2012

      27 Germano G, "Automatic quantitation of regional myocardial wall motion and thickening from gated technetium-99m sestamibi myocardial perfusion single-photon emission computed tomography" 30 : 1360-1367, 1997

      28 Rozovsky K, "Added value of SPECT/CT for correlation ofMIBG scintigraphy and diagnostic CT in neuroblastoma and pheochromocytoma" 190 : 1085-1090, 2008

      29 Germano G, "A new algorithm for the quantitation of myocardial perfusion SPECT. I: technical principles and reproducibility" 41 : 712-719, 2000

      30 Davison CM, "A comparison of FDG-PET and blood flow SPECT in the diagnosis of neurodegenerative dementias : a systematic review" 29 : 551-561, 2014

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2016-12-26 학술지명변경 한글명 : Nuclear Medicine and Molecular Imaging -> Nuclear Medicine and Molecular Imaging
      외국어명 : 미등록 -> Nuclear Medicine and Molecular Imaging
      KCI등재
      2011-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2010-03-12 학술지명변경 한글명 : 핵의학 분자영상 -> Nuclear Medicine and Molecular Imaging KCI등재
      2009-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2007-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2005-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2002-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      1999-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.06 0.06 0.06
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.09 0.08 0.275 0
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼