RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCI SCIE SCOPUS

      Subnormal Binocular Contrast Sensitivity Summation in Patients with Intermittent Exotropia

      한글로보기

      https://www.riss.kr/link?id=A106054376

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

      Background: To evaluate binocular summation ratio using contrast sensitivity (CS) testing and correlation between binocular summation and stereoacuity, and control scale in intermittent exotropia (IXT).
      Methods: We conducted a prospective case-control study. Thirty-seven IXT and 41 controls were evaluated with both monocular and binocular CS testing. We compared the binocular summation ratio of IXT to that of controls. Near and distance stereoacuity was assessed and office-based control scale was evaluated. We investigated correlation between binocular CS summation ratio and stereoacuity, and control scale in IXT, respectively.
      Results: IXT had lower binocular CS summation ratio than controls at 1.5 and 3.0 cycles/ degree (1.01 ± 1.02 vs. 1.62 ± 1.88 and 1.17 ± 0.96 vs. 1.86 ± 1.75, Both P < 0.05). We found significant correlation between binocular CS summation ratio at 3.0 cycles/degree and both near and distance stereoacuity (r = −0.411, P = 0.012 and r = −0.624, P = 0.005), and ratio at 1.5 cycles/degree also correlated significantly with distance stereoacuity (r = −0.397, P = 0.034) in the IXT. Binocular CS summation ratio was correlated to control scale at 1.5 and 3.0 cycles/ degree (r = −0.327, P = 0.041 and r = −0.418, P = 0.028), and the ratio significantly differed in control scale groupings analysis at the same frequencies (Both P < 0.05).
      Conclusion: Our findings of subnormal binocular CS summation ratio in IXT had correlation with stereoacuity and control scale suggest that binocular CS testing may be a useful method in assessing binocular visual function in IXT.
      번역하기

      Background: To evaluate binocular summation ratio using contrast sensitivity (CS) testing and correlation between binocular summation and stereoacuity, and control scale in intermittent exotropia (IXT). Methods: We conducted a prospective case-contro...

      Background: To evaluate binocular summation ratio using contrast sensitivity (CS) testing and correlation between binocular summation and stereoacuity, and control scale in intermittent exotropia (IXT).
      Methods: We conducted a prospective case-control study. Thirty-seven IXT and 41 controls were evaluated with both monocular and binocular CS testing. We compared the binocular summation ratio of IXT to that of controls. Near and distance stereoacuity was assessed and office-based control scale was evaluated. We investigated correlation between binocular CS summation ratio and stereoacuity, and control scale in IXT, respectively.
      Results: IXT had lower binocular CS summation ratio than controls at 1.5 and 3.0 cycles/ degree (1.01 ± 1.02 vs. 1.62 ± 1.88 and 1.17 ± 0.96 vs. 1.86 ± 1.75, Both P < 0.05). We found significant correlation between binocular CS summation ratio at 3.0 cycles/degree and both near and distance stereoacuity (r = −0.411, P = 0.012 and r = −0.624, P = 0.005), and ratio at 1.5 cycles/degree also correlated significantly with distance stereoacuity (r = −0.397, P = 0.034) in the IXT. Binocular CS summation ratio was correlated to control scale at 1.5 and 3.0 cycles/ degree (r = −0.327, P = 0.041 and r = −0.418, P = 0.028), and the ratio significantly differed in control scale groupings analysis at the same frequencies (Both P < 0.05).
      Conclusion: Our findings of subnormal binocular CS summation ratio in IXT had correlation with stereoacuity and control scale suggest that binocular CS testing may be a useful method in assessing binocular visual function in IXT.

      더보기

      참고문헌 (Reference)

      1 Hatt SR, "Variability of stereoacuity in intermittent exotropia" 145 (145): 556-561, 2008

      2 Hess RF, "The threshold contrast sensitivity function in strabismic amblyopia: evidence for a two type classification" 17 (17): 1049-1055, 1977

      3 Cheng A, "The role of the magnocellular pathway in serial deployment of visual attention" 20 (20): 2188-2192, 2004

      4 Smith EL 3rd, "The relationship between binocular rivalry and strabismic suppression" 26 (26): 80-87, 1985

      5 Romanchuk KG, "The natural history of surgically untreated intermittent exotropia-looking into the distant future" 10 (10): 225-231, 2006

      6 Chen Z, "The effect of Bangerter filters on binocular function in observers with amblyopia" 56 (56): 139-149, 2014

      7 Poggio GF, "The analysis of stereopsis" 7 (7): 379-412, 1984

      8 Haggerty H, "The Newcastle Control Score: a new method of grading the severity of intermittent distance exotropia" 88 (88): 233-235, 2004

      9 Holmes JM, "Stability of near stereoacuity in childhood intermittent exotropia" 15 (15): 462-467, 2011

      10 Kattan JM, "Relationship between binocular summation and stereoacuity after strabismus surgery" 165 (165): 29-32, 2016

      1 Hatt SR, "Variability of stereoacuity in intermittent exotropia" 145 (145): 556-561, 2008

      2 Hess RF, "The threshold contrast sensitivity function in strabismic amblyopia: evidence for a two type classification" 17 (17): 1049-1055, 1977

      3 Cheng A, "The role of the magnocellular pathway in serial deployment of visual attention" 20 (20): 2188-2192, 2004

      4 Smith EL 3rd, "The relationship between binocular rivalry and strabismic suppression" 26 (26): 80-87, 1985

      5 Romanchuk KG, "The natural history of surgically untreated intermittent exotropia-looking into the distant future" 10 (10): 225-231, 2006

      6 Chen Z, "The effect of Bangerter filters on binocular function in observers with amblyopia" 56 (56): 139-149, 2014

      7 Poggio GF, "The analysis of stereopsis" 7 (7): 379-412, 1984

      8 Haggerty H, "The Newcastle Control Score: a new method of grading the severity of intermittent distance exotropia" 88 (88): 233-235, 2004

      9 Holmes JM, "Stability of near stereoacuity in childhood intermittent exotropia" 15 (15): 462-467, 2011

      10 Kattan JM, "Relationship between binocular summation and stereoacuity after strabismus surgery" 165 (165): 29-32, 2016

      11 Birch E, "Random dot stereoacuity of preschool children. ALSPAC "Children in Focus" Study Team" 34 (34): 217-222, 1997

      12 Hatt SR, "Quantifying variability in the measurement of control in intermittent exotropia" 19 (19): 33-37, 2015

      13 Ingling CR Jr, "Perceptual correlates of magnocellular and parvocellular channels: seeing form and depth in afterimages" 30 (30): 823-828, 1990

      14 Pineles SL, "One eye or two: a comparison of binocular and monocular low-contrast acuity testing in multiple sclerosis" 152 (152): 133-140, 2011

      15 Holmes JM, "New tests of distance stereoacuity and their role in evaluating intermittent exotropia" 114 (114): 1215-1220, 2007

      16 Campbell FW, "Monocular versus binocular visual acuity" 208 (208): 191-192, 1965

      17 Pelli DG, "Measuring contrast sensitivity" 90 : 10-14, 2013

      18 Leske DA, "Maximum angle of horizontal strabismus consistent with true stereopsis" 8 (8): 28-34, 2004

      19 Brodsky MC, "Intermittent exotropia and accommodative esotropia: distinct disorders or two ends of a spectrum?" 122 (122): 1543-1546, 2015

      20 Jimenez JR, "Induced aniseikonia diminishes binocular contrast sensitivity and binocular summation" 81 (81): 559-562, 2004

      21 Pineles SL, "Improvement in binocular summation after strabismus surgery" 133 (133): 326-332, 2015

      22 Carmel D, "How to create and use binocular rivalry" (45) : 1-10, 2010

      23 Howland B, "High-pass spatial frequency letters as clinical optotypes" 18 (18): 1063-1066, 1978

      24 Pineles SL, "Functional burden of strabismus: decreased binocular summation and binocular inhibition" 131 (131): 1413-1419, 2013

      25 Nishikawa N, "Distance stereotesting using vision test charts for intermittent exotropia" 9 : 1557-1562, 2015

      26 Stathacopoulos RA, "Distance stereoacuity. Assessing control in intermittent exotropia" 100 (100): 495-500, 1993

      27 Jampolsky A, "Differential diagnostic characteristics of intermittent exotropia and true exophoria" 4 (4): 48-55, 1954

      28 Chung ST, "Comparing the shape of contrast sensitivity functions for normal and low vision" 57 (57): 198-207, 2016

      29 Mohney BG, "Common forms of childhood exotropia" 110 (110): 2093-2096, 2003

      30 Amigo G, "Binocular vision tested with visual evoked potentials in children and infants" 17 (17): 910-915, 1978

      31 Blake R, "Binocular vision" 51 (51): 754-770, 2011

      32 Lema SA, "Binocular summation in normal and stereoblind humans" 17 (17): 691-695, 1977

      33 Yulek F, "Binocular summation and control of intermittent exotropia" 25 (25): 81-86, 2017

      34 Pardhan S, "Binocular inhibition: psychophysical and electrophysiological evidence" 67 (67): 688-691, 1990

      35 Legge GE, "Binocular contrast summation--II. Quadratic summation" 24 (24): 385-394, 1984

      36 Legge GE, "Binocular contrast summation--I. Detection and discrimination" 24 (24): 373-383, 1984

      37 Pardhan S, "Binocular contrast summation and inhibition in amblyopia. The influence of the interocular difference on binocular contrast sensitivity" 82 (82): 239-248, 1992

      38 Mohney BG, "An office-based scale for assessing control in intermittent exotropia" 14 (14): 147-150, 2006

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2011-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2009-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2005-01-01 평가 SCI 등재 (등재유지) KCI등재
      2002-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      1999-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 1.48 0.37 1.06
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.85 0.75 0.691 0.11
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼