      Effect of an Air Cleaner with Electrostatic Filter on the Removal of Airborne House Dust Mite Allergens

      한글로보기

      https://www.riss.kr/link?id=A101616814

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

      Purpose: The effects of air cleaners on the removal of airborne indoor allergens,especially house dust mites (HDM), are still controversial. The objective of this study is to evaluate the effect of an air cleaner with an electrostatic filter on the removal of airborne mite allergens. Materials and Methods: A dried HDM culture medium that contained mite body particles and excretions was dispersed in a chamber equipped with an electrostatic air cleaner. The number of airborne particles was recorded continuously by a dust spectrometer for 60 minutes.
      Airborne particles in the chamber were collected on a sampling filter at a flow rate of 10 L/min and the Der f 1 concentration in the filter extracts was measured by two-site ELISA. Results: The air cleaner efficiently removed airborne HDM particles. The air cleaner removed airborne HDM particles (size 2-12.5 μm) 11.4 ±2.9 fold (cleaner operating for 15 minutes), 5.4 ± 0.7 fold (cleaner operating for 30minutes), and 2.4 ± 0.2 fold (cleaner operating for 60 minutes) more than the removal of HDM particles by natural settle down. Removal kinetics differed according to the particle size of the airborne particles. The air cleaner decreased the concentration of Der f 1 in the extraction of airborne particles collected on the air sampling filter by 60.3%. Conclusion: The electrostatic air cleaner can remove airborne HDM allergens and may be useful as a supplementary environmental control tool for HDM sensitized respiratory allergic patients.
      번역하기

      Purpose: The effects of air cleaners on the removal of airborne indoor allergens,especially house dust mites (HDM), are still controversial. The objective of this study is to evaluate the effect of an air cleaner with an electrostatic filter on the re...

      Purpose: The effects of air cleaners on the removal of airborne indoor allergens,especially house dust mites (HDM), are still controversial. The objective of this study is to evaluate the effect of an air cleaner with an electrostatic filter on the removal of airborne mite allergens. Materials and Methods: A dried HDM culture medium that contained mite body particles and excretions was dispersed in a chamber equipped with an electrostatic air cleaner. The number of airborne particles was recorded continuously by a dust spectrometer for 60 minutes.
      Airborne particles in the chamber were collected on a sampling filter at a flow rate of 10 L/min and the Der f 1 concentration in the filter extracts was measured by two-site ELISA. Results: The air cleaner efficiently removed airborne HDM particles. The air cleaner removed airborne HDM particles (size 2-12.5 μm) 11.4 ±2.9 fold (cleaner operating for 15 minutes), 5.4 ± 0.7 fold (cleaner operating for 30minutes), and 2.4 ± 0.2 fold (cleaner operating for 60 minutes) more than the removal of HDM particles by natural settle down. Removal kinetics differed according to the particle size of the airborne particles. The air cleaner decreased the concentration of Der f 1 in the extraction of airborne particles collected on the air sampling filter by 60.3%. Conclusion: The electrostatic air cleaner can remove airborne HDM allergens and may be useful as a supplementary environmental control tool for HDM sensitized respiratory allergic patients.

      더보기

      참고문헌 (Reference)

      1 Shaughnessy RJ, "What is an effective portable air cleaning device? A review" 3 : 169-181, 2006

      2 Waring MS, "Ultrafine particle removal and generation by portable air cleaners" 42 : 5003-5014, 2008

      3 Green R, "The effect of air filtration on airborne dog allergen" 54 : 484-488, 1999

      4 Tovey ER, "The distribution of dust mite allergen in the houses of patients with asthma" 124 : 630-635, 1981

      5 Tovey ER, "Mite faeces are a major source of house dust allergens" 289 : 592-593, 1981

      6 De Lucca S, "Mite allergen (Der p 1) is not only carried on mite feces" 103 : 174-175, 1999

      7 Wahn U, "Indoor allergen exposure is a risk factor for sensitization during the first three years of life" 99 : 763-769, 1997

      8 Eggleston PA, "Improving indoor environments: reducing allergen exposures" 116 : 122-126, 2005

      9 Sheikh A, "House dust mite avoidance measures for perennial allergic rhinitis" 24 : CD001563-, 2007

      10 Sporik R, "Exposure to house-dust mite allergen (Der p I) and the development of asthma in childhood. A prospective study" 323 : 502-507, 1990

      1 Shaughnessy RJ, "What is an effective portable air cleaning device? A review" 3 : 169-181, 2006

      2 Waring MS, "Ultrafine particle removal and generation by portable air cleaners" 42 : 5003-5014, 2008

      3 Green R, "The effect of air filtration on airborne dog allergen" 54 : 484-488, 1999

      4 Tovey ER, "The distribution of dust mite allergen in the houses of patients with asthma" 124 : 630-635, 1981

      5 Tovey ER, "Mite faeces are a major source of house dust allergens" 289 : 592-593, 1981

      6 De Lucca S, "Mite allergen (Der p 1) is not only carried on mite feces" 103 : 174-175, 1999

      7 Wahn U, "Indoor allergen exposure is a risk factor for sensitization during the first three years of life" 99 : 763-769, 1997

      8 Eggleston PA, "Improving indoor environments: reducing allergen exposures" 116 : 122-126, 2005

      9 Sheikh A, "House dust mite avoidance measures for perennial allergic rhinitis" 24 : CD001563-, 2007

      10 Sporik R, "Exposure to house-dust mite allergen (Der p I) and the development of asthma in childhood. A prospective study" 323 : 502-507, 1990

      11 Vaughan JW, "Evaluation of materials used for bedding encasement: effect of pore size in blocking cat and dust mite allergen" 103 : 227-231, 1999

      12 Ferguson P, "Environmental and bronchoalveolar lavage Dermatophagoides pteronyssinus antigen levels in atopic asthmatics" 151 : 71-74, 1995

      13 Antonicelli L, "Efficacy of an air-cleaning device equipped with a high efficiency particulate air filter in house dust mite respiratory allergy" 46 : 594-600, 1991

      14 Custovic A, "Dust mite allergens are carried on not only large particles" 10 : 258-260, 1999

      15 Reisman RE, "Do air cleaners make a difference in treating allergic disease in homes?" 87 : 41-43, 2001

      16 Svartengren M, "Deposition of large particles in human lung" 12 : 75-88, 1987

      17 Sulser C, "Can the use of HEPA cleaners in homes of asthmatic children and adolescents sensitized to cat and dog allergens decrease bronchial hyperresponsiveness and allergen contents in solid dust" 148 : 23-30, 2009

      18 Platts-Mills TAE, "Airborne allergens associated with asthma: particle sizes carrying dust mite and rat allergens measured with a cascade impactor" 77 : 850-857, 1986

      19 Fox RW, "Air cleaners: a review" 94 : 413-416, 1994

      20 de Blay F, "Air borne dust mite allergens: comparison of group II allergens with group I mite allergen and cat-allergen Fel d 1" 88 : 919-926, 1991

      21 Hinds WC, "Aerosol technology: properties, behaviors, and measurement of airborne particles" Wiley-Interscience Publication 1998

      22 Association of Home Appliance Manufacturers (AHAM), "AHAM method for measuring performance of portable household electric room air cleaners. ANSI/AHAM AC-1-2006; Revision of ANSI/AHAM AC-1-2002 and AHAM AC-1-2005"

      23 Wood RA, "A placebo-controlled trial of a HEPA air cleaner in the treatment of cat allergy" 158 : 115-120, 1998

      24 Reisman RE, "A double-blind study of the effectiveness of a high-efficiency particulate air (HEPA) filter in the treatment of patients with perennial allergic rhinitis and asthma" 85 : 1050-1057, 1990

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2011-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2009-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2007-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2005-05-31 학술지등록 한글명 : Yonsei Medical Journal
      외국어명 : Yonsei Medical Journal
      KCI등재
      2005-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2002-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2000-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 1.42 0.3 0.99
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.83 0.72 0.546 0.08
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼