RISS 학술연구정보서비스

검색

인기 검색어

    다국어 입력

    http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

    변환된 중국어를 복사하여 사용하시면 됩니다.

    예시)
    • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
    • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
    닫기
    KCI등재

    디지털 방사선사진술을 이용한 치아색 수복물의 방사선불투과도 비교 = RADIOPACITY COMPARISON OF TOOTH COLORED RESTORATIVE MATERIALS WITH DIGITAL RADIOGRAPHY

    한글로보기

    https://www.riss.kr/link?id=A3007228

    • 0

      상세조회
    • 0

      다운로드
    서지정보 열기
    • 내보내기
    • 내책장담기
    • 공유하기
      • URL 복사
    • 오류접수
    인용문이 복사되었습니다.

    부가정보

    다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

    The purposes of this study were to evaluate the validity of 2 kinds of digital radiography techniques in evaluating the radiopacity comparison of restorative materials and to determine the relative radiopacities of several kinds of compomer and flowable resin using these techniques.
    After taking radiographs of an aluminum step wedge, correlation of optical density calibration curves were evaluated between conventional radiography with transmission densitometer and CD-Dent digital radiography (storage phosphor system) and between conventional one and RVG□ digital radiography (CCD system).
    Compomers such as Dyract□ AP, Compoglass□, and Dyract flow□, and flowable resins such as Ultraseal XT□ plus™, Revolution™, Aeliteflo™ and Tetric-flow□ were used. Five specimens of 5mm in diameter and 2mm thick were fabricated with each material. Radiopacities of the materials were measured using the above radiographic techniques and compared.
    The results were as follows :
    1. When the optical density calibration curves were compared, conventional radiography and both CD-Dent and RVG□ digital radiographies showed very high inverse correlations (γ= -0.95, γ= -0.98 ; p<0.05).
    2. All the tested restorative materials showed levels of radiopacity the same as or greater than that of dentin (p<0.05). Radiopacities of Dyract□ AP, Compoglass□, and Tetric flow□ were greater than those of Revolution™, Aeliteflo™, or dentin (p<0.05).
    3. Radiopacities of Dyract□ AP, Compoglass□, and Tetric flow□ were shown to be greater than that of enamel when conventional radiography and CD-Dent digital radiography were used (p<0.05). Radiopacity of Dyract flow□ was shown to be greater than that of Enamel when conventional radiography was used (p<0.05).
    번역하기

    The purposes of this study were to evaluate the validity of 2 kinds of digital radiography techniques in evaluating the radiopacity comparison of restorative materials and to determine the relative radiopacities of several kinds of compomer and flowab...

    The purposes of this study were to evaluate the validity of 2 kinds of digital radiography techniques in evaluating the radiopacity comparison of restorative materials and to determine the relative radiopacities of several kinds of compomer and flowable resin using these techniques.
    After taking radiographs of an aluminum step wedge, correlation of optical density calibration curves were evaluated between conventional radiography with transmission densitometer and CD-Dent digital radiography (storage phosphor system) and between conventional one and RVG□ digital radiography (CCD system).
    Compomers such as Dyract□ AP, Compoglass□, and Dyract flow□, and flowable resins such as Ultraseal XT□ plus™, Revolution™, Aeliteflo™ and Tetric-flow□ were used. Five specimens of 5mm in diameter and 2mm thick were fabricated with each material. Radiopacities of the materials were measured using the above radiographic techniques and compared.
    The results were as follows :
    1. When the optical density calibration curves were compared, conventional radiography and both CD-Dent and RVG□ digital radiographies showed very high inverse correlations (γ= -0.95, γ= -0.98 ; p<0.05).
    2. All the tested restorative materials showed levels of radiopacity the same as or greater than that of dentin (p<0.05). Radiopacities of Dyract□ AP, Compoglass□, and Tetric flow□ were greater than those of Revolution™, Aeliteflo™, or dentin (p<0.05).
    3. Radiopacities of Dyract□ AP, Compoglass□, and Tetric flow□ were shown to be greater than that of enamel when conventional radiography and CD-Dent digital radiography were used (p<0.05). Radiopacity of Dyract flow□ was shown to be greater than that of Enamel when conventional radiography was used (p<0.05).

    더보기

    목차 (Table of Contents)

    • Ⅰ.서론
    • Ⅱ.재료 및 방법
    • 1.재료
    • 2.시편제작
    • 3.방사선촬영 및 방사선불투과도 측정
    • Ⅰ.서론
    • Ⅱ.재료 및 방법
    • 1.재료
    • 2.시편제작
    • 3.방사선촬영 및 방사선불투과도 측정
    • 4.통계적 분석
    • Ⅲ.성적
    • 1.Aluminum step wedge 광학밀도 측정곡선
    • 2.수복재의 방사선불투과도
    • Ⅳ.고찰
    • Ⅴ.요약
    더보기

    동일학술지(권/호) 다른 논문

    분석정보

    View

    상세정보조회

    0

    Usage

    원문다운로드

    0

    대출신청

    0

    복사신청

    0

    EDDS신청

    0

    동일 주제 내 활용도 TOP

    더보기

    주제

    연도별 연구동향

    연도별 활용동향

    연관논문

    연구자 네트워크맵

    공동연구자 (7)

    유사연구자 (20) 활용도상위20명

    해외이동버튼