RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      경골에 시행한 생비골 및 생피부편 이식의 임상적 연구 = Clinical Study of Vascularized Osteocutaneous Fibular Transfer to the Tibia

      한글로보기

      https://www.riss.kr/link?id=A101438296

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

      Recent advances in microsurgery have made it possible to provide a continued circulation of blood to the grafted bone so as to ensure viability. With the nutrient blood supply preserved, healing of the graft to the recipient bone is facilitated without the usual replacement of the graft by creeping substitution. We reviewed 34 cases of vascularized osteocutaneous fibular transfers to the infected tibial defect complicated with skin defect, which were performed from May, 1982 to January, 1992, and the following results were obtained: 1. Despite of uncontrolled bone infection with skin defect, the vascularized osteocutaneous fibular flap transfer could be performed. 2. In the vascularized osteocutaneous fibula transfer, the patency of anastomoses could be indirectly monitored by observing the color of the skin flap. 3. The vascularized fibula had been hypertrophied with bony union during the follow-up period of 13 months to 6 years and 4 months(average, 30 months) and there was no resorption of the grafted fibula. 4. There was no fracture of the grafted fibula in parti resection of involved tibia. 5. The hypertrophic potentiality of grafted fibula could be inhibited by the infection status as operation site.
      번역하기

      Recent advances in microsurgery have made it possible to provide a continued circulation of blood to the grafted bone so as to ensure viability. With the nutrient blood supply preserved, healing of the graft to the recipient bone is facilitated withou...

      Recent advances in microsurgery have made it possible to provide a continued circulation of blood to the grafted bone so as to ensure viability. With the nutrient blood supply preserved, healing of the graft to the recipient bone is facilitated without the usual replacement of the graft by creeping substitution. We reviewed 34 cases of vascularized osteocutaneous fibular transfers to the infected tibial defect complicated with skin defect, which were performed from May, 1982 to January, 1992, and the following results were obtained: 1. Despite of uncontrolled bone infection with skin defect, the vascularized osteocutaneous fibular flap transfer could be performed. 2. In the vascularized osteocutaneous fibula transfer, the patency of anastomoses could be indirectly monitored by observing the color of the skin flap. 3. The vascularized fibula had been hypertrophied with bony union during the follow-up period of 13 months to 6 years and 4 months(average, 30 months) and there was no resorption of the grafted fibula. 4. There was no fracture of the grafted fibula in parti resection of involved tibia. 5. The hypertrophic potentiality of grafted fibula could be inhibited by the infection status as operation site.

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼