RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      $^{18}F$-FDG PET 검사를 위한 당뇨 환자의 혈당 조절에 관한 연구 = A Study of Diabetic Control for Diabetic Patient in $^{18}F$-FDG PET

      한글로보기

      https://www.riss.kr/link?id=A101518680

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Purpose: $^{18}F$-FDG PET is to evaluate the tumor using glucose metabolism. Blood Glucose Level (BGL) is important factor that affects on a result of examination. But it often appears the distort result on diabetic patient due to a failure of BGL control. The aim of this study is to make a effective guideline for diabetic patient prescribed $^{18}F$-FDG PET and improve accuracy and reliability of examination. Materials and methods: A subject of study is 69 diabetic patients and divided them into 3 groups; 1) BGL is less than 120 mg/dl & performed PET, 2) BGL is over than 120 mg/dl & performed PET, 3) BGL is over than 120 mg/dl & not performed PET. And we investigated the type of diabetic medications and the time of dosage, whether they have meal or not. And we analyzed SUV of liver and mediastinum to recognize the effect of BGL on PET images. Results: As a methods to diabetic control, Amalyl showed high percentage of 27.5% in oral medication and Humulin R showed 14.5% in insulin. Their peak time was 2-3 hrs, 2-4 hrs and duration time was 24 hrs, 5-7 hrs. The number of that had a breakfast was 16, 7 mens (43.8%) couldn't perform PET as over 120 mg/dl and 5 mens (31.3%) performed PET as less than 120 mg/dl after they took a medication. When we set the SUV of normal for 1.5-2.0, 1.0-1.5 on liver and mediastinum, the percentage out of the range was 31.8%, 52.9%, 62.5% in 120-139 mg/dl, 140-159 mg/dl, 160-200 mg/dl respectively. Conclusions: We completed standardized guideline for diabetic patients. As a result of this study, improved customer satisfaction and increased economic benefits. It is expect to be a effective model in other PET centers.
      번역하기

      Purpose: $^{18}F$-FDG PET is to evaluate the tumor using glucose metabolism. Blood Glucose Level (BGL) is important factor that affects on a result of examination. But it often appears the distort result on diabetic patient due to a failure of BGL con...

      Purpose: $^{18}F$-FDG PET is to evaluate the tumor using glucose metabolism. Blood Glucose Level (BGL) is important factor that affects on a result of examination. But it often appears the distort result on diabetic patient due to a failure of BGL control. The aim of this study is to make a effective guideline for diabetic patient prescribed $^{18}F$-FDG PET and improve accuracy and reliability of examination. Materials and methods: A subject of study is 69 diabetic patients and divided them into 3 groups; 1) BGL is less than 120 mg/dl & performed PET, 2) BGL is over than 120 mg/dl & performed PET, 3) BGL is over than 120 mg/dl & not performed PET. And we investigated the type of diabetic medications and the time of dosage, whether they have meal or not. And we analyzed SUV of liver and mediastinum to recognize the effect of BGL on PET images. Results: As a methods to diabetic control, Amalyl showed high percentage of 27.5% in oral medication and Humulin R showed 14.5% in insulin. Their peak time was 2-3 hrs, 2-4 hrs and duration time was 24 hrs, 5-7 hrs. The number of that had a breakfast was 16, 7 mens (43.8%) couldn't perform PET as over 120 mg/dl and 5 mens (31.3%) performed PET as less than 120 mg/dl after they took a medication. When we set the SUV of normal for 1.5-2.0, 1.0-1.5 on liver and mediastinum, the percentage out of the range was 31.8%, 52.9%, 62.5% in 120-139 mg/dl, 140-159 mg/dl, 160-200 mg/dl respectively. Conclusions: We completed standardized guideline for diabetic patients. As a result of this study, improved customer satisfaction and increased economic benefits. It is expect to be a effective model in other PET centers.

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼