      흡수성 SR-Poly(L/DL)-lactide(70/30) 고정장치를 이용한 하악골절의 고정 = Fixation of Mandibular Fracture with Bioabsorbable Self-reinforced Poly(L/DL)-actide 70/30%) Plate and Screw

      한글로보기

      https://www.riss.kr/link?id=A104554504

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Metal fixation device, titanium miniplate is commonly used in facial bone fixation. But metal fixation device requires secondary removal procedure because of such complications as bony atrophy, metallic corrosion, low carcinogenic risk, growth disturbance of craniofacial skeleton, and endocranial migration of device which may lead to pediatric craniofacial surgery. Bioabsorbable plates lose strength retention after a given period of time unlike metalic plates, are degraded and absorbed completely in human body. Because they yield no metalic complications nor risks, and require no secondary removal, their use has been recently increased in fixation of facial bone.Self-inforced(SR)-poly(L/DL) lactide(70/30%) plate is applied for the fixation of midfacial bone in adult. But its weak strength brings concern about the skeletal stability, and makes surgeons hesitate its application to mandibular fractures. SR-poly(L/DL) lactide are rarely used especially in mandibular fractures. The authors used Biosorb FX 2.0 plate in 58 patients of mandibular fractures by open reduction and internal fixation. The duration of intermaxillary fixation was 7 days in 12 patients of multiple fractures. Follow-up period was 4 to 16 months(mean; 12 months). Complications included 2 cases with malocclusion, 6 cases with sensory disturbance and no infection was reported. The malocclusion was solved by minimal occlusal grinding, and sensory disturbance was temporary. The authors applied bicortical fixation of two plate system(thickness 1.2mm) with long screws or large diameter screws to mandibular fractures and obtained sufficient skeletal stability. The risk of tissue reaction associated with possible postimplantative crystallization of SR-poly(L/DL) lactide(70/ 30%) could be reduced. They report their experiences with review of literature.
      번역하기

      Metal fixation device, titanium miniplate is commonly used in facial bone fixation. But metal fixation device requires secondary removal procedure because of such complications as bony atrophy, metallic corrosion, low carcinogenic risk, growth disturb...

      Metal fixation device, titanium miniplate is commonly used in facial bone fixation. But metal fixation device requires secondary removal procedure because of such complications as bony atrophy, metallic corrosion, low carcinogenic risk, growth disturbance of craniofacial skeleton, and endocranial migration of device which may lead to pediatric craniofacial surgery. Bioabsorbable plates lose strength retention after a given period of time unlike metalic plates, are degraded and absorbed completely in human body. Because they yield no metalic complications nor risks, and require no secondary removal, their use has been recently increased in fixation of facial bone.Self-inforced(SR)-poly(L/DL) lactide(70/30%) plate is applied for the fixation of midfacial bone in adult. But its weak strength brings concern about the skeletal stability, and makes surgeons hesitate its application to mandibular fractures. SR-poly(L/DL) lactide are rarely used especially in mandibular fractures. The authors used Biosorb FX 2.0 plate in 58 patients of mandibular fractures by open reduction and internal fixation. The duration of intermaxillary fixation was 7 days in 12 patients of multiple fractures. Follow-up period was 4 to 16 months(mean; 12 months). Complications included 2 cases with malocclusion, 6 cases with sensory disturbance and no infection was reported. The malocclusion was solved by minimal occlusal grinding, and sensory disturbance was temporary. The authors applied bicortical fixation of two plate system(thickness 1.2mm) with long screws or large diameter screws to mandibular fractures and obtained sufficient skeletal stability. The risk of tissue reaction associated with possible postimplantative crystallization of SR-poly(L/DL) lactide(70/ 30%) could be reduced. They report their experiences with review of literature.

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2012-01-15 학술지명변경 한글명 : 대한성형외과 학회지 -> Archives of Plastic Surgery
      외국어명 : Journal of The Korean Society of Plastic and Reconstructive Surgeons -> Archives of Plastic Surgery
      KCI등재
      2011-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2009-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2007-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2004-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2003-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2001-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.12 0.12 0.12
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.12 0.11 0.335 0.02
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼